3A6342 FENFor professional use only. Not approved for use in explosive atmospheres or hazardous locations. For portable airless spraying of architectural paints and : 695 / 795 / 1095 / 1595 / Mark IV HD/ Mark V HD/ Mark VII HD/ Mark X HD3300 psi (228 bar, MPa) Maximum Working PressureSee page 4 for additional model only genuine Graco replacement use of non-Graco replacement parts may void Safety InstructionsRead all warnings and instructions in this manual and in Related Manuals listed on page 2 before using the equipment. Be familiar with the controls and the proper usage of the equipment. Save all , Parts695 / 795 / 1095 / 1595 / Mark IV HD/ Mark V HD/ Mark VII HD/ Mark X HD Electric Airless SprayersBefore You Spray 23A6342 FBefore You SprayReview Warnings for Important Safety InformationImportant! Read carefully and practice good safety Manuals3A6285 Contractor PC Spray Gun311254 Flex Plus Spray Gun309495 Heavy-Duty InLine Spray Gun308491 Heavy-Duty Texture Spray Gun3A6584 Displacement Pump3A6583 ProConnect Displacement PumpManuals can also be found at You Spray.

• Verify that all containers and collection syste ms are grounded to prevent static discharge. Do not use pail liners unless they are anti-static or conductive. • Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2 adapter. • Do not use a paint or a solvent containing halogenated hydrocarbons.

Tags:

  Sys tems, Syste

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of See page 4 for additional model information. Important ...

1 3A6342 FENFor professional use only. Not approved for use in explosive atmospheres or hazardous locations. For portable airless spraying of architectural paints and : 695 / 795 / 1095 / 1595 / Mark IV HD/ Mark V HD/ Mark VII HD/ Mark X HD3300 psi (228 bar, MPa) Maximum Working PressureSee page 4 for additional model only genuine Graco replacement use of non-Graco replacement parts may void Safety InstructionsRead all warnings and instructions in this manual and in Related Manuals listed on page 2 before using the equipment. Be familiar with the controls and the proper usage of the equipment. Save all , Parts695 / 795 / 1095 / 1595 / Mark IV HD/ Mark V HD/ Mark VII HD/ Mark X HD Electric Airless SprayersBefore You Spray 23A6342 FBefore You SprayReview Warnings for Important Safety InformationImportant! Read carefully and practice good safety Manuals3A6285 Contractor PC Spray Gun311254 Flex Plus Spray Gun309495 Heavy-Duty InLine Spray Gun308491 Heavy-Duty Texture Spray Gun3A6584 Displacement Pump3A6583 ProConnect Displacement PumpManuals can also be found at You Spray.

2 2 Contents .. 3 Models .. 4 Warnings .. 7 Know Your Sprayer .. 11 Know Your Controls .. 14 Setup .. 15 Assemble Your Sprayer .. 15 QuikReel .. 16 Grounding .. 17 Power Requirements .. 17 Extension Cords .. 17 Pails ..17 Start Up .. 18 Pressure Relief Procedure .. 1810/16 Amp Switch .. 1915/20 Amp Switch .. 19 Flush Storage Fluid .. 19 Strain the Paint .. 20 Fill Pump (Prime Pump) .. 21 Fill Spray Gun and Hose .. 21 Refilling Paint Pail .. 22 Spraying .. 23 Cleanup .. 26 WatchDog ..29 BlueLink App .. 30 LED Display ..32 Maintenance ..35 Troubleshooting .. 36695/795 Lo-Boy Standard Parts .. 50695/795/Mark IV HD Hi-Boy Standard Parts .. 521095/1595/Mark V HD/Mark VII HD Hi-Boy Standard Parts .. 54 Mark X HD Standard Parts .. 56695/795/Mark IV HD ProContractor Parts .. 581095/1595/Mark V HD/Mark VII HD ProContractor Parts .. 60 Mark X HD ProContractor Parts.

3 621095/1595/Mark V HD /Mark VII HD IronMan Parts .. 64 Mark X HD IronMan Parts .. 66 ProContractor QuikReel .. 68 Spray Gun and Hose .. 69 Filter .. 70 Control .. 72 Wiring Diagrams .. 74 Technical Specifications .. 78 Compliance ..86 Radio Frequency Approvals .. 86 California Proposition 65 .. 86 Graco Standard Warranty .. 87 Graco Information .. 88 Models 43A6342 FModels695 Models795 ModelsVoltageModelStandard Lo-BoyStandard Hi-BoyProContractor120 NEMA 5-15 Ultra Max II 69517E57217E57417E577 Ultimate MX II 695826222826223826224230 CEE 7/7 Ultra Max II 69517E63217E635230 Europe MultiUltra Max II 69517E63317E636110 UKUltra Max II 69517E63417E637230 ANZ/KRUltra Max II 69517E61017E61317E614230 APUltra Max II 69526C981100 Japan/TaiwanUltra Max II 69526C98226C983 VoltageModelStandard Lo-BoyStandard Hi-BoyProContractor120 NEMA 5-15 Ultra Max II 79517E57917E582 Ultimate MX II 795826225826226230 CEE 7/7 Ultra Max II 79517E63917E642230 Europe MultiUltra Max II 79517E64017E643110 UKUltra Max II 79517E64117E644230 ANZ/KRUltra Max II 79517E61617E61717E619230 APUltra Max II 79526C984100 Japan/TaiwanUltra Max II 79526C98526C986 Models3A6342F51095 Models1595 ModelsVoltageModelStandard Hi-BoyProContractorIronMan120 NEMA 5-15

4 Ultra Max II 109517E58317E58517E586 Ultimate MX II 1095826227826228826229230 CEE 7/7 Ultra Max II 109517E64617E64717E650230 Europe Multi Ultra Max II 109517E648230 ANZ/KRUltra Max II 109517E62017E62117E623230 APUltra Max II 109526C987100 Japan/TaiwanUltra Max II 109526C98826C989 VoltageModelStandard Hi-BoyProContractorIronMan120 NEMA 5-20 Ultimate MX II 1595826233 Ultra Max II 159517E593120 NEMA 5-15 Ultra Max II 159517E58917E59617E594 Ultimate MX II 1595826230826232826234 Models 63A6342 FMark HD ModelsVoltageModelStandard Hi-BoyProContractorIronMan120 NEMA 5-15 Mark IV HD17E60317E604120 NEMA 5-20 Mark V HD17E628120 NEMA 5-15 Mark V HD17E60517E60617E607230 NEMA L6-30 Mark X HD17E60817E609230 CEE 7/7 Mark IV HD17E65117E653 Mark V HD17E65517E66017E664 Mark VII HD17E66517E66717H895 Mark X HD17E66917E67117H897230 Europe MultiMark IV HD17E65217E654 Mark V HD17E661 Mark VII HD17E66617E66817H896 Mark XHD17E67017E67217H898110 UKMark V HD17E65917E662230 ANZ/KRMark V HD17E66317E629 Mark VII HD26C993 Mark X HD17E674230 APMark IV HD17E624 Mark V HD17E65726C990 Mark VII HD26C992 Mark X HD17E67326C995100 Japan/TaiwanMark V HD26C991 Warnings3A6342F7 WarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment.

5 The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. Improper installation of the grounding plug is able to result in a risk of electric shock. When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal.

6 The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire. Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded. Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician. This product is for use on a nominal 120 V or 230 V circuit and has a grounding plug similar to the plugs illustrated in the figure below. Only connect the product to an outlet having the same configuration as the plug. Do not use a 3-to-2 adapter with this Cords: Use only a 3-wire extension cord that has a grounding plug and a grounding receptacle that accepts the plug on the product. Make sure your extension cord is not damaged. If an extension cord is necessary use 12 AWG ( ) minimum to carry the current that the product draws.

7 An undersized cord results in a drop in line voltage and loss of power and US230V230V ANZ230V IndiaConductor SizeLengthAWG (American Wire Gauge) mm250 ft. (15 m)Warnings 83A6342 FFIRE AND EXPLOSION HAZARDF lammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: Do not spray flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment. Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray system, including the pump, Hose assembly, Spray Gun, and objects in and around the spray area shall be properly grounded to protect against static discharge and sparks. Use Graco conductive or grounded high-pressure airless paint sprayer hoses.

8 Verify that all containers and collection systems are grounded to prevent static discharge. Do not use pail liners unless they are anti-static or conductive. Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2 adapter. Do not use a paint or a solvent containing halogenated hydrocarbons. Do not spray flammable or combustible liquids in a confined area. Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. Sprayer generates sparks. Keep pump assembly in a well ventilated area a least 20 feet ( m) from the spray area when spraying, flushing, cleaning, or servicing. Do not spray pump assembly. Do not smoke in the spray area or spray where sparks or flame is present. Do not operate light switches, engines, or similar spark producing products in the spray area. Keep area clean and free of paint or solvent containers, rags, and other flammable materials.

9 Know the contents of the paints and solvents being sprayed. Read all Safety Data Sheets (SDSs) and container labels provided with the paints and solvents. Follow the paint and solvents manufacturer s safety instructions. Keep a working fire extinguisher in the work SHOCK HAZARDThis equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock. Turn off and disconnect power cord before servicing equipment. Connect only to grounded electrical outlets. Use only 3-wire extension cords. Ensure ground prongs are intact on power and extension cords. Do not expose to rain. Store indoors. Wait five minutes after disconnecting power cord before INJECTION HAZARDHigh-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, get immediate surgical treatment. Do not aim the Spray Gun at, or spray any person or animal.

10 Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body. Always use the nozzle tip guard. Do not spray without nozzle tip guard in place. Use Graco nozzle tips. Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs while spraying, follow the Pressure Relief Procedure for turning off the unit and relieving the pressure before removing the nozzle tip to clean. Equipment maintains pressure after power is shut off. Do not leave the equipment energized or under pressure while unattended. Follow the Pressure Relief Procedure when the equipment is unattended or not in use, and before servicing, cleaning, or removing parts. Check hoses and parts for signs of damage. Replace any damaged hoses or parts. This system is capable of producing 3000 psi (207 bar, MPa). Use Graco replacement parts or accessories that are rated a minimum of 3000 psi (207 bar, MPa).