A CA6 Contactors A120visit for pricing and the most up to date - All pricing shown in US dollars215mm( 8 15/32 )630A860 ASeries CA6 ContactorsA classic contactor for demanding applications from 75 to 600HP (@460V) -100 to 700HP (@ 575V) Sprecher + Schuh s CA6 contactor line combines the simple function of our popular CA7 Series with the rugged performance demanded in this middle horsepower range. On average these Contactors are 50% smaller than tradi-tional Contactors in this size broad selection for middle horsepower applicationsThe CA6 range consists of nine Contactors in three frame sizes covering motors from 75 to 600HP at 460V and from 100 to 700HP at 575V. This line is ideally suited for demanding applications such as steel mills, rock quarries, mines or for any middle horsepower application where a sturdy, durable contactor is and reliableCA6 Contactors conform to UL508, IEC 60947 and can be operated at rated voltages up to 600V (UL) and 1000V (IEC).

CA6 Contactors Reversing, Three Pole Contactors With DC Coil, Series CA6 (Open type only) Open Type UL/CSA HP DC DC

Tags:

  Series, Contactors

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Series CA6 Contactors - Sprecher + Schuh

1 A CA6 Contactors A120visit for pricing and the most up to date - All pricing shown in US dollars215mm( 8 15/32 )630A860 ASeries CA6 ContactorsA classic contactor for demanding applications from 75 to 600HP (@460V) -100 to 700HP (@ 575V) Sprecher + Schuh s CA6 contactor line combines the simple function of our popular CA7 Series with the rugged performance demanded in this middle horsepower range. On average these Contactors are 50% smaller than tradi-tional Contactors in this size broad selection for middle horsepower applicationsThe CA6 range consists of nine Contactors in three frame sizes covering motors from 75 to 600HP at 460V and from 100 to 700HP at 575V. This line is ideally suited for demanding applications such as steel mills, rock quarries, mines or for any middle horsepower application where a sturdy, durable contactor is and reliableCA6 Contactors conform to UL508, IEC 60947 and can be operated at rated voltages up to 600V (UL) and 1000V (IEC).

2 High thermal and switching capacities guarantee reli-able operation and long life. CA6 Contactors are listed in CSA Certified Elevator Equipment for heavy duty use in elevators, refrigerators and heating installations in quenching extends contact lifeAll CA6 Contactors are designed with sophisticated arc quenching techniques that extinguish damaging breaking arcs quickly. This is accomplished by guid-ing the arc away from the contacts and into arc chambers which are built-in to every CA6 firstCA6 arc chambers are completely enclosed (without arc exhaust vents), offering the best protection against hot arcing gases. A large safety distance in front of the contactor is unnecessary. CA6 Contactors are also designed so that operation is impossible if the arc chambers are removed. Conversely, once the contactor is energized, the arc chambers cannot be used with terminal covers or HB Touch-Safe Lugs, CA6 Contactors meet international standards for touch-safe ( 4 3/4 ) 115A155mm( 6 3/32 )210A250A300A420A120mm( 4 3/4 )

3 140A 180 ADISCONTINUEDThis Series is being replaced by the CA9 Series of contactorsA CA6 Contactors A121visit for pricing and the most up to date - All pricing shown in US dollars 10 3 4 6 7 9 8 1 5 2 11 Electronic coils offer many advantagesBehind the attractive outward appear-ance of the CA6 contactor are advanced engineering solutions that offer con-venience and savings. The entire line can be equipped with an electronically controlled coil that reduces pick-up currents by 60% on average. Holding current is also advantages of the CA6 electronic coil include: Direct connection to a PLC Overvoltage protection and suppres-sion circuits (eliminating interfer-ence from the coil) are standardThe entire CA6 line is modularly de-signed for easy inspection, coil change and contact replacement.

4 Maintenance can be performed from the front so that mounting requires no additional space. Even with the installation of mechanical interlocks and auxiliary contact blocks, the units can be flush mounted side by side, saving panel CA6-115-EI Contactor2 CA6-140-EI Contactor3 Main Terminal Set4 Lug set5 Mechanical Interlock6 Aux. Contact Block7 Aux. Contact Block8 Aux. Contact Block9 Aux. Contact Block10 Terminal Cover11 Surge SuppressorComparison of pick-up andholding current [VA] Smooth, even operation over the entire voltage range minimizes the possibility of contact bounce No safeguards are necessary to bridge brief supply interruptions Precisely defined pick-up and drop-out voltages, eliminate the possibility of chattering Electronic coils operate over a much broader voltage range, providing flexibility in applications and lower costs due to reduced inventoryCA6 EI electronic coils offer many unique advantages over conventional typesTwo user-selectable modesCA6 Contactors with electronic coils operate in either the E mode for nor-mal operation or the EI mode for in-terfacing directly with a Programmable Logic Controller (PLC) or other low level signal source ( VDC).

5 The coil is set in the E mode from the factory, offering all of the functions and advantages of an electronic coil with the exception of electronic interface. An orange jumper located on the bottom of the contactor can be quickly changed if interface from a PLC is desired. A de-tailed technical explanation of CA6-EI coils along with connection diagrams can be found in the Technical set in E mode (factory default)Jumper set in EI mode (user selectable)CA6 Contactors utilize modular design techniques that speed installation, reduce panelspace and facilitate maintenancepick-upholding Conventional Coil Electronic Coil210018001500120090060030001234567891 1 DISCONTINUEDA CA6 Contactors A122visit for pricing and the most up to date informationSSNA2018 Discount Schedule - All pricing shown in US dollarsNon-Reversing, Three Pole Contactors With AC Coil, Series CA6 (Open type only) Contactors - AC CoilThree Pole - Series CA6CA6 EI coils are electronically controlled coils with the following characteristics: Ability to connect directly to a low level signal source such as a PLC (13-30 VDC at 15mA max.)

6 Very low pull-in and holding current for Contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coilNote: CA6 open-type Contactors include terminal bolts. If lugs are required, see page A129 for ordering contactorCA6-420-EI contactorIe [A]Ratings for Switching AC Motors (AC2 / AC3 )Auxiliary Contacts per ContactorOpen TypeCatalog Number PricekW (50 Hz)UL/CSA HP (60 Hz)230V400V/415V500V690V1 3 AC-3AC-1115V230V200V230V460V575 VNONC1152503764/6680111102540407510011CA 6-115-11- CA6-115-EI-11- 6698051402504578/8280 1111530405010012511CA6-140-11- CA6-140-EI-11- 1100125018025057101/10598 135 ~40506015015011CA6-180-11- CA6-180-EI-11- 1540175021035067118/122147205~5060751502 0011CA6-210-EI-11- 185025035080140/145177250~~7510020025011 CA6-250-EI-11- 209030045097170/176213293~~1001252503001 1CA6-300-EI-11- 2330420540135238/250298424~~150175350400 11CA6-420-EI-11- 4920630800200355450500~~20025050060011CA 6-630-EI-11- 87708601000250500560~~~25030060070011CA6 -860-EI-11- 11900 Specify Catalog NumberReplace ( )

7 With Coil CodeSee Coil Codeson this pageOrdering InstructionsCoil Codes -EI designates contactor with Electronic Interface coil. Other voltages available, see page A134-A135. For CSA Elevator duty rating, consult Technical Information on page A139. Ratings are higher for Contactors with electronic coil: CA6-140-EI-11- CA6-180-EI-11- 500V = 98 kW 500V = 126 kW 690V = 135 kW 690V = 176 kW 24 VAC Coil is not available for CA6-420-EI. Coil is rated /140 /180 ACCoil CodeVoltage Range50 Hz60 Hz24~24V120B110V120V208~208V240B220-230V 240V277240V277V380380-400V440V480415V480 V575500V575 VCA6-115-EI ..CA6-420-EI ACCoil CodeVoltage Range50 Hz / 60 Hz24 24V120110-130V220W208-277V460W380-500 VCA6-630-EI ..CA6-860-EI ACCoil CodeVoltage Range50 Hz / 60 Hz120110-130V 208W200-220V240W230-250V 277277V480440-480 VDISCONTINUEDA CA6 Contactors A123visit for pricing and the most up to date informationSSNA2018 Discount Schedule - All pricing shown in US dollarsCA6-140-EI contactor with DC coilCA6-420-EI contactor with DC coilNon-Reversing, Three Pole Contactors With DC Coil, Series CA6 (Open type only) Contactors - DC CoilThree Pole - Series CA6CA6 EI coils are electronically controlled coils with the following characteristics: Ability to connect directly to a low level signal source such as a PLC (13-30 VDC at 15mA max.)

8 Very low pull-in and holding current for Contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coilNote: CA6 open-type Contactors include terminal bolts. If lugs are required, see page A129 for ordering [A]Ratings for Switching AC Motors (AC2 / AC3)Auxiliary Contacts per ContactorOpen TypeCatalog Number PricekW (50 Hz)UL/CSA HP (60 Hz)230V400V/415V500V690V1 3 AC-3AC-1115V230V200V230V460V575 VNONC1152503764/66801111025404075100111C A6-115-L22- CA6-115-EI-11- 8079201402504578/8280 11115304050100125111CA6-140-L22- CA6-140-EI-11- 1380156018025057101/10598 135 ~40506015015011 1CA6-180-L22- CA6-180-EI-11- 1910219021035067118/122147205~5060751502 0011CA6-210-EI-11- 229025035080140/145177250~~7510020025011 CA6-250-EI-11- 259030045097170/176213293~~1001252503001 1CA6-300-EI-11- 2920420540135238/250298424~~150175350400 11CA6-420-EI-11- 6130630800200355450500~~20025050060011CA 6-630-EI-11- 87708601000250500560~~~25030060070011CA6 -860-EI-11- 11900 Specify Catalog NumberReplace ( )

9 With Coil CodeSee Coil Codeson this pageOrdering InstructionsCoil Codes -EI designates contactor with Electronic Interface coil. Other voltages available, see page A134-A135. For CSA Elevator duty rating, consult Technical Information on page A139. Ratings are higher for Contactors with electronic coil: CA6-140-EI-11- CA6-180-EI-11- 500V = 98 kW 500V = 126 kW 690V = 135 kW 690V = 176 kW 24V DC Coil not available for CA6-420-EI. Customers selecting 24V DC Coils should consider the EI functionality of the CA6 (see page A148). Coil is rated / 140 / 180 DCCoil CodeVoltage Range24D24V110D110V220D220 VNote: Conventional DC coils have high current pick-up winding and low current seal-in winding wired in parallel. The pick-up winding is taken out of the circuit after the armature pulls in. Price includes two winding coil and an L11 block including one NC late break auxiliary contact mounted on the right side.

10 See page A149 for functional DC Coil CodeVoltage Range24D DC Coil CodeVoltage Range120110-130V 240W200-255V DISCONTINUEDA CA6 Contactors A124visit for pricing and the most up to date informationSSNA2018 Discount Schedule - All pricing shown in US dollarsReversing, Three Pole Contactors With AC Coil, Series CA6 (Open type only) Contactors , AC Coil ReversingThree Pole - Series CAU6CA6 EI coils are electronically controlled coils with the following characteristics: Ability to connect directly to a low level signal source such as a PLC (13-30 VDC at 15mA max.) Very low pull-in and holding current for Contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coilNote: CA6 open-type Contactors include terminal bolts.