Service Instructions - HVACDirect.com
this air conditioner is not meant to provide unattended cooling or life support for persons or animals who are unable to react to the failure of this product. the failure of an unattended air condition-er may result in extreme heat in the cond-itioned space causing overheating or death of persons or animals. precautions must be taken to warn of or
Tags:
Services, Instructions, Service instructions
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
TECHNICAL MANUAL - HVACDirect.com
hvacdirect.comare of the sweat type for field piping with refrigerant type cop-per. Front seating valves are factory installed to accept the field run copper. The total refrigerant charge for a normal in-stallation is factory installed in the condensing unit. GSX units are charged for the matching evaporator coil and a 15 foot refrigerant line set.
Downflow & Upflow Models - HVACDirect.com
hvacdirect.comcoil housing and plenum connector. No separate ... Filtering Methods - Downflow Furnaces Non-Ducted Return Air For unducted return air systems, either the optional grille ... For ducted return air systems with air conditioners or heat pumps, either providing an access panel in the duct
TECHNICAL SUPPORT MANUAL Two--Stage Split System …
hvacdirect.com•Recovery cylinder service pressure rating must be 400 psig, DOT 4BA400 or DOT BW400. •R--410A systems should be charged with liquid refrigerant. Use a commercial type metering device in the manifold hose when charging into suction line with compressor operating.
Services, Manual, System, Technical, Support, Split, Stage, Technical support manual two stage split system
NEW DUCT SIZING CHART - HVAC Direct
hvacdirect.comDesign CFM 4" CFM 6" CFM 8" CFM 10" CFM 12" 60 6x4 60 4x6 90 4x8 120 4x10 150 4x12 90 8x4 110 6x6 160 6x8 215 6x10 270 6x12 120 10x4 160 8x6 230 8x8 310 8x10 400 8x12 150 12x4 215 10x6 310 10x8 430 10x10 550 10x12 180 14x4 270 12x6 400 12x8 550 12x10 680 12x12 210 16x4 320 14x6 490 14x8 670 14x10 800 14x12 240 18x4 375 16x6 580 16x8 800 16x10 950 …
ARUF**14** / ASPT**14**
hvacdirect.comIn applications where the air handler is installed in the hori-zontal left position, and the return air environment see humidity levels above 65% relative humidity coupled with total external static levels above 0.5” e.s.p., a condensate kit is available for field application. Kit nomenclature can be found in Table 1. CMK0008 Condensate Kit ...
MODEL 700 SERIES HUMIDIFIER - HVACDirect.com
hvacdirect.comWARM AIR PLENUM Aprilaire to be installed as shown in relation to cooling coils. RECOMMENDED WIRING DIAGRAMS (SEE STEP 6 ON BACK AND “HUMIDIFIER CONTROL SAFETY AND INSTALLATION INSTRUCTIONS” FOR DETAILED WIRING INSTRUCTIONS) 90-922 90-921 RETURN RETURN HOTWATER SUPPLY SUPPLY Orientation of Aprilaire Model …
ACNF, AWUF, ADPF, ARPF, ARUF, AEPF, ASPF ATUF Air Handlers
hvacdirect.comthese regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. WARNING ... listed in the 2001 Florida Building Code, Chapter 13, Section 610.2.A.2.1. PRODUCT DIMENSIONS 6 ACNF
MG1E Series Furnaces FEATURES and BENEFITS Ignition
hvacdirect.commanufactured and modular homes These units incor. porate high efficiency, reliability, and low maintenance Units ma. y be installed free standing in a utility room or enclosed in an alcove or closet. MG1 Series furnaces are available in A/C adaptable or A/C ready, with or without coil cavity FEATURES and BENEFITS TECHNICAL SPECIFICATIONS
Up to 96% AFUE, Variable--Speed, Two--Stage Gas Furnace
hvacdirect.comSpecificationsaresubject tochangewithout notice. 44051480002 9/6/19 Up to 96% AFUE, Variable--Speed, Two--Stage Gas Furnace EASIER TO SELL S Up to 96% AFUE in upflow and horizontal positions 95% AFUE in downflow position
Speed, Variable, Stage, Downflow, Furnace, Uefa, Variable speed, Two stage gas furnace
Related documents
ROOM AIR CONDITIONER WALL MOUNTED TYPE
www.fujitsu-general.comroom air conditioner wall mounted type heat & cool model (reverse cycle) keep this operation manual for future reference guarde este manual de uso para futuras consultas guarde este manual de funcionanento para referÊncia futura fujitsu general limited p/n9315345318-03 operating manual
Fire Rated Wall Assemblies Other CertainTeed Products for ...
www.certainteed.comair ducts for heating, ventilating and air conditioning systems. (Pictured above: ToughGard duct board.) FOR ADDITIONAL INFORMATION: PUB. NO. 30-34-006 Ultra*Duct™ GOLD Duct Board with Enhanced Surface Ultra*Duct™ GOLD Duct Board is a rigid board designed for fabrication into supply and return air HVAC duct work. Composed
Product, Other, Walls, Assemblies, Certainteed, Wall assemblies other certainteed products for
GLASS CURTAIN WALL - City University of New York
openlab.citytech.cuny.eduAir Barriers & Sealants *Air barrier materials act to reduce air leakage through a building assembly. *Sealant is a rubberlike, adhesive material, usually applied in liquid or tape form used to seal a joint, gap, or crack against the passage of air and moisture.
Dedicated Outdoor Air Systems - Trane
www.trane.comthrough-the-wall air conditioners (PTACs), variable-refrigerant-flow (VRF) terminals, passive chilled beams, and radiant cooling surfaces. Figure 2. Advantages: Disadvantages: • Makes it easier to ensure the required amount of outdoor air reaches each zone, because separate ventilation diffusers allow easy airflow measurement and balancing
DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL …
www.daikinac.comOperate the air conditioner in a suffi ciently ventilated area and not surrounded by obstacles. Do not use the air conditioner in the following places. a. Places with a mist of mineral oil, such as cutting oil. b. Locations such as coastal areas where there is a lot of salt in the air.