Example: bachelor of science

Service Quick Guide OOLING - Indesit Company

COOLINGS ervice Quick GuideService Quick GuideIndesit Company , Service DepartmentSQG_CL_31_EN1/3 Fault Table - New Platform Artica Electronic Fridge-FreezersFaultF01F02F05F07F08F09F1 0F12F16F22F23F24F25F26 LED interface Fault display LED1 LED2 LED3 Off Flashing Off On Flashing Off Flashing Flashing On Off Flashing Flashing Flashing Flashing Spento Flashing Flashing Flashing On Off Off Off Off On Off

C Service Quick Guide OOLING Indesit Company, Service Department SQG_CL_31_EN 1/3 Fault Table - New Platform Artica Electronic Fridge …

Tags:

  Services, Guide, Company, Quick, Indesit, Service quick guide ooling, Ooling, Indesit company, Service quick guide ooling indesit company

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Service Quick Guide OOLING - Indesit Company

1 COOLINGS ervice Quick GuideService Quick GuideIndesit Company , Service DepartmentSQG_CL_31_EN1/3 Fault Table - New Platform Artica Electronic Fridge-FreezersFaultF01F02F05F07F08F09F1 0F12F16F22F23F24F25F26 LED interface Fault display LED1 LED2 LED3 Off Flashing Off On Flashing Off Flashing Flashing On Off Flashing Flashing Flashing Flashing Spento Flashing Flashing Flashing On Off Off Off Off On Off

2 Off Off Flashing On On Flashing On Flashing Off On Flashing On Off Flashing Flashing Off OnFor Digital interfaces with 7-segment digits (Fig. 2) faults are di-splayed by means of a message on the 7-segment : Faults Table New Platform Artica Electronic Fridge-FreezersFor Led interfaces (Fig. 1), faults are displayed by means of the Leds (Faults Table 1)F=FaultN =XXLED2 LED3 LED1(Fig. 1)(Fig. 2)Fault Table - New Platform Artica Electronic Fridge-Freezers2/3 FAULTCHECKSCAUSE- Check effi ciency of contacts on connector J1 on PCB;- Check the ohmic continuity on wiring connector J014 pins 2 and 1, checking the ohmic value of the fan;- Check for correct connection of the freezer fan at the freezer compartment junction box;- Replace compressor;- Replace freezer fan unit;- Replace Check effi ciency of contacts on connector J1 on PCB;- Check that there is a consistent impedance value on wiring connector J1 between pins 3 and 2;- Check the motor terminal block (possible problems due to faulty connection).

3 - Check that the compressor is not in temperature timeout (thermal cutout open).- Replace compressor;- Replace Check effi ciency of contacts on connector J018 on PCB;- Check effi ciency of electronic damper connection at foam-protected connector behind multifl ow;- Replace electronic damper;- Replace Check effi ciency of connector contacts on PCB: J003 on appliance with Artica Full and J001 on appliances with Artica Entry;- Check continuity of defrost heating element on pins 3 and 4 of the above con-nector, checking the impedance value is consistent;- Check correct connection of the defrost heating element at the freezer compart-ment junction box;- Check for correct ohm value of the defrost heating element across the terminals of the element.

4 - Check the fuses have not blown;- Replace the element;- Replace Check effi ciency of connector contacts on PCB: J002 on appliance with Artica Full and J001 on appliances with Artica Entry;- Check ohmic continuity on pins 1 and 2 of the above connector, checking the ohm value given is consistent;- Check that the solenoid valve switches (open the doors for 5 min. close the doors and switch off the fridge compartment);- Replace the solenoid valve;- Replace Reprogram Setting fi le;- Replace Check effi ciency of contacts on connector J002 on PCB;- Check for ohmic continuity on wiring connector J002 pins 3 and 4, checking the ohm value is consistent;- Check that the solenoid valve switches (open the doors for 5 min.)

5 Close the doors and switch off the fridge compartment).- Replace the solenoid valve;- Replace Check effi ciency of contacts on connector J012 on PCB;- Check continuity of connector J012/4-way interface PCB connector;- Check effi ciency of connector contacts on display PCB;- Replace main PCB;- Replace display Check effi ciency of contacts of J009 connector on PCB;- Check the ohmic continuity on wiring connector J009 pins 1 and 2, checking the ohm value is consistent;- Check for correct connection of the fridge fan in the fridge compartment;- Replace fridge fan unit;- Replace main Main PCBC ompressor relay openF05F02F07F08 STEPPER DAMPER:contact faulty/not wired, wiring disconnected, motor coils discon-nected.

6 Pilot circuit fault on PCB, fault feedback F09 DEFROST HEATING ELEMENT:contact faulty/not wired, wiring disconnected, fuse open, element disconnected, element ground fault (discharges to earth); triac in short-circuit, fault Appliance, SOLENOID VALVE 1:contact faulty/not wired, wiring disconnected, solenoid valve coil disconnected; triac in short circuit, fault feedback Setting file error detected by main boardStatic Appliance, Artica Full only. SOLENOID VALVE 2:contact faulty/not wired, wiring disconnected, solenoid valve coil disconnected; triac in short circuit, feedback on F12fault only on Artica communication between UI board and Main boardonly on Artica FAN: contact faulty/not wired, wiring disconnected, motor winding dis-connected;triac in short circuit, fault feedbackF16 COOLING3/3 Fault Table - New Platform Artica Electronic Fridge-FreezersFAULTCHECKSCAUSE- Check effi ciency of contacts on connector J016 on PCB.

7 - Check the NTC probe, checking at connector J016 (pins 1 and 2 for Artica High, pins 3 and 4 for Artica Entry) that the impedance value is consistent with the data in the temperature-impedance correlation table; - Heat the probe by hand contact where possible and check the change in the resistance value;- In the event the probe is wrongly calibrated, cut the appropriate wiring PCB side;- Replace main Check effi ciency of contacts on connector J016 on PCB;- Check the NTC probe, checking at connector J016 (pins 7 and 8 for Artica High, pins 1 and 2 for Artica Entry) that the impedance value is consistent with the data in the temperature-impedance correlation table;- Heat the probe by hand contact where possible and check the change in the resistance value;- In the event the probe is wrongly calibrated, cut the appropriate wiring PCB side;- Replace main Check effi ciency of contacts on connector J016 on PCB;- Check the NTC probe, checking at connector J016 (pins 3 and 4 for Artica High, pins 5 and 6 for Artica Entry) that the impedance value is consistent with the data in the temperature-impedance correlation table;- Heat the probe by hand contact where possible and check the change in the resistance value;- In the event the probe is wrongly calibrated, cut the appropriate wiring PCB side.

8 - Replace main Check effi ciency of contacts on connector J016 on PCB;- Check the NTC probe, checking on connector J016 (pins 7 and 8 for Artica High, pins 1 and 2 for Artica Entry) that the impedance value is consistent with the data in the temperature-impedance correlation table;- Heat the probe by hand contact where possible and check the change in the resistance value;- In the event the probe is wrongly calibrated, cut the appropriate wiring PCB side;- Replace main Check effi ciency of contacts on connector J016 on PCB;- Check the NTC probe, checking on wiring connector J016 pins 5 and 6 that the impedance value is consistent with the data in the temperature-impedance correlation table;- Heat the probe by hand contact where possible and check the change in the resistance value;- In the event the probe is wrongly calibrated, cut the appropriate wiring PCB side;- Replace main AIR PROBE:probe not wired, wiring discon-nected/short circuit, probe open/ short circuitF25 Static Appliance,FRIDGE EVAP.

9 PROBE:probe not wired, wiring discon-nected/short circuit, probe open/ short circuitF26 FREEZER AIR PROBE:probe not wired, wiring discon-nected/short circuit, probe open/ short circuitNo Frost Appliance,FREEZER EVAP. PROBE:probe not wired, wiring discon-nected/short circuit, probe open/short circuitOnly on Artica AIR PROBE:probe not wired, wiring discon-nected/short circuit, probe open/short circuit