Single-Pole/3-Way 120v Models: 277v Models: Preset Fluorescent Dimmer AYF- 103p AYF- 103p -277. Installation Instructions DVF- 103p DVF- 103p -277. Please Leave for Occupant DVSCF- 103p DVSCF- 103p -277. Package Contents 5. Capacity: Dimmer Approx. No. Max. model of lamps Current*. AYF- 103p 20 8A. DVF- 103p 20 8A. DVSCF- 103p 20 8A. Ariadni Diva AYF- 103p -277 40 6A. Single-Pole/3-Way dimmer DVF- 103p -277 40 6A. DVSCF- 103p -277 40 6A. Mounting screws (2) * As measured from incoming hot wire Wire connectors: (blue) on dimmer. To determine total single-pole cap off (1,small) load on the dimmer circuit, refer to Single-Pole/3-Way (6) ballast label. Each ballast has an associated input current. The total load is found by adding up all the ballast currents for all ballasts on the dimmer. Important Notes 6.

5. Capacity: Dimmer Approx. No. Max. Model of lamps Current* AYF-103P 20 8A DVF-103P 20 8A DVSCF-103P 20 8A AYF-103P-277 40 6A DVF-103P-277 40 6A DVSCF-103P-277 40 6A

Tags:

  Model, Repset, 120v, 103p, 277v, 120v models, 277v models

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Single-Pole/3-Way 120V Models: 277V Models: Preset ...

1 Single-Pole/3-Way 120v Models: 277v Models: Preset Fluorescent Dimmer AYF- 103p AYF- 103p -277. Installation Instructions DVF- 103p DVF- 103p -277. Please Leave for Occupant DVSCF- 103p DVSCF- 103p -277. Package Contents 5. Capacity: Dimmer Approx. No. Max. model of lamps Current*. AYF- 103p 20 8A. DVF- 103p 20 8A. DVSCF- 103p 20 8A. Ariadni Diva AYF- 103p -277 40 6A. Single-Pole/3-Way dimmer DVF- 103p -277 40 6A. DVSCF- 103p -277 40 6A. Mounting screws (2) * As measured from incoming hot wire Wire connectors: (blue) on dimmer. To determine total single-pole cap off (1,small) load on the dimmer circuit, refer to Single-Pole/3-Way (6) ballast label. Each ballast has an associated input current. The total load is found by adding up all the ballast currents for all ballasts on the dimmer. Important Notes 6.

2 Use only the lamp types listed on the label of the ballast. Compact fluorescent 1. CAUTION: To reduce the risk of lamps must have 4 pins for dimming. overheating and possible damage to 7. AYF- 103p , DVF- 103p , and DVSCF- other equipment, do not use to control 103p operate at 120v only. AYF- 103p - receptacles, motor-operated appliances, 277, DVF- 103p -277, and DVSCF- 103p - or transformer-supplied appliances. 277 operate at 277v only. 2. These dimmers require a neutral 8. In multi-phase applications, use a connection in the wallbox. If your separate neutral for each dimmer circuit. wallbox does not have a neutral, one If further information is necessary, must be run. The dimmers will not contact the Lutron Hotline 1-800-523- operate without one. 9466. 3. When no grounding means exist within 9.

3 Do not use two dimmers in the same 3- the wallbox then the NEC 2002, Article way circuit. 404-9 allows a dimmer without a 10. Wire dimmer in accordance with all grounding connection to be installed as national and local electrical codes. a replacement, as long as a plastic, 11. This dimmer is designed to operate in noncombustible wallplate is used. For temperatures between 0 C and 40 C. this type of installation, cap or remove (32 F to 104 F). the green ground wire on the dimmer 12. The Diva dimmer is compatible with and use an appropriate wallplate such designer-style and Lutron screwless as Lutron's Claro or FassadaTM series Claro wallplates. The Ariadni dimmer wallplates. is compatible with standard wallplates 4. Use with Lutron Hi-lume FDB or Eco- and Lutron FassadaTM wallplate.

4 10TM Electronic Fluorescent Dimming Wallplates are not included. Ballasts only. Do not use with any other 13. The wire connectors provided are ballasts. suitable for copper wire only. They can be used to join one No. 18, 16, 14, 12, or 10 gauge wire with one or two No. 14. or 12 gauge wires. 14. Clean dimmer with a soft damp cloth only. Do not use any chemical cleaners. Multigang Installations 4A. Single-pole wiring (See Single-Pole Wiring Diagram). Dimmers can be grouped together or with Connect the bare or green ground wire standard switches under a common of the dimmer to the bare or green wallplate. When ganging these dimmers, ground wire in the wallbox. remove the inner side sections. No capacity Using a wire connector provided, cap off derating is required for these dimmers.

5 The violet wire. This wire is only used in Remove all inner side sections a 3-way installation. (shaded) in any ganged installation. Connect the white dimmer wire to the neutral wire in the wallbox. Connect the blue dimmer wire to the 120v or 277v supply (hot) wire. Connect the red dimmer wire to the wire going to the black wire of the ballasts. Connect the yellow dimmer wire to the Do not remove outer side sections. wire going to the orange wire of the ballasts. Before Installation 4B. 3-way wiring (See 3-Way Wiring Diagram). CAUTION: Check new installations for short Connect the bare or green ground wire circuits BEFORE installing the fluorescent of the dimmer to the bare or green dimmer. Turn power OFF at circuit breaker ground wire in the wallbox. or fusebox. Connect a standard switch as Connect the white dimmer wire to the shown in the Test Switch Wiring Diagram.

6 Neutral wire in the wallbox. Turn power ON. If lights do not come on, a Connect the blue dimmer wire to one of break in the wiring exists. If the breaker the two wires coming from the other trips, there is a short in the wiring. If switch location. necessary, turn power OFF and correct any Connect the violet dimmer wire to the wiring problems, recheck the circuit, then second wire coming from the other proceed to Installation. Warranty is void if switch location. dimmer is turned ON in a shorted circuit. Connect the red dimmer wire to the wire going to the black wire of the ballasts. Installation Connect the yellow dimmer wire to the 1. WARNING: Turn power OFF at circuit wire going to the orange wire of the breaker or remove fuse. ballasts. 5. Mount and align dimmer. Do not pinch OFF OFF OFF.

7 ON. wires. ON. ON. 2. Remove test switch from wallbox. 6. Screw on faceplate. 7. Turn power ON. OFF OFF OFF. ON. 3. Strip insulation or trim wires to expose ON. 1/2" or 5/8" of wire: ON. 1/2" for 10, 12, and 14 gauge. 5/8" for 16 and 18 gauge. 1/2"or 5/8". Test Switch Wiring Diagram To additional Lutron Dimming Ballasts Standard Switch ORANGE. BLACK. WHITE Lutron Dimming Ballast HOT. 120v , 60Hz or 277v , 60Hz ORANGE. BLACK. NEUTRAL WHITE Lutron Dimming Ballast Single Pole Wiring Diagram To additional Lutron Dimming Ballasts Diva or Ariadni Orange Dimmer Black Yellow White Lutron Dimming Ballast Hot Blue Red Cap off Violet Green or 120v , 60Hz Bare or White 277v , 60Hz Ground Orange Black Neutral White Lutron Dimming Ballast Yellow White Red Blue Note: Wire location will vary by product.

8 Reference wires by color, Violet Green or Bare Ground not location. 3-Way Wiring Diagram To additional Lutron Dimming Ballasts 3-way Diva or Ariadni Switch Dimmer Yellow Orange Blue Black Hot Violet Red White Lutron Dimming Ballast Green or Bare 120v , 60Hz or White 277v , 60Hz Ground Ground Orange Black Neutral White Lutron Dimming Ballast Yellow White Red Note: Wire location will vary by Blue product. Reference wires by color, Violet not location. Green or Bare Ground Ariadni Operation Lamp Aging Best dimming performance is Toggle switch achieved after new lamps have been Slider aged (burned-in) by running at full turns lights moves up to on to Preset brighten intensity for at least 100 hours. level. and down to dim lights to desired level. Minimum Light Level Adjustment This unit is factory calibrated and does not normally require low-end True 3-way.

9 Light level adjustment. If lamps flicker A 3-way dimmer and a standard 3- or drop out at the minimum dimming way switch provide Preset switching level, there may be an installation from both locations and light level error or the low-end light level may control from the dimmer. need to be reset. Continued use of the system in this mode will cause Diva Operation premature lamp failure. If this is occurring, call the Lutron Technical Support Center at: 1-800-523-9466. Paddle Slider switch moves up turns to brighten lights on and down to Preset to dim level. lights to desired level. Limited Warranty Lutron will, at its option, repair or replace any unit True 3-way. that is defective in materials or manufacture within one year after purchase. For warranty service, A 3-way dimmer and a standard 3- return unit to place of purchase or mail to Lutron at way switch provide Preset switching 7200 Suter Rd.

10 , Coopersburg, PA 18036-1299, from both locations and light level postage pre-paid. THIS WARRANTY IS IN LIEU OF ALL OTHER. control from the dimmer. EXPRESS WARRANTIES, AND THE IMPLIED. WARRANTY OF MERCHANTABILITY IS LIMITED. TO ONE YEAR FROM PURCHASE. THIS. Technical Assistance WARRANTY DOES NOT COVER THE COST OF. INSTALLATION, REMOVAL OR. If you have questions concerning the REINSTALLATION, OR DAMAGE RESULTING. FROM MISUSE, ABUSE, OR DAMAGE FROM. installation or operation of this IMPROPER WIRING OR INSTALLATION. THIS. product, call the Lutron Technical WARRANTY DOES NOT COVER INCIDENTAL. OR CONSEQUENTIAL DAMAGES. Support Center. Please provide This warranty gives you specific legal rights, and exact model number when calling. you may have other rights which vary from state to (800) 523-9466 ( , Canada, state.)