SN Series - Safety Shower & Combination Unit Heaters

SN Series - Safety Shower & Combination unit HeatersTankless water heating Solutions 2013 Keltech Incorporated729 South Grove Street, Delton, Michigan 49046 Phone: 800-999-4320 Fax: 1 of 4 This information is subject to change without notice. 2/8/2013 Emergency Fixtures Document No. 4986 Industry s Lowest Pressure Drop Through the System Copper and Brass Heat Exchanger Dual PID Temperature Controller with Full Modulating Temperature Control Capabilities Solid-State Relay Switching Three-Tier Anti-Scald Protection Patented Latent Heat Removal Independent Temperature Limit Cut-Offs Door Cut-Off Switch Controller-Locked Temperature Setting NEMA 4 Enclosure Standard 480 and 600V, 3-Phase Standard 144kw Accommodates Two Combination Units Activated SimultaneouslyStandard EquipmentTankless water heating SpecificationsKeltech, Inc. tankless Shower Heaters provide warm water intended to supply Safety fixtures, with no neutral required (no transformer needed).

Tankless Water Heating Specifications Keltech, Inc. Tankless Shower Heaters provide warm water intended to supply safety fixtures, with no neutral required (no transformer needed).

Tags:

  Series, Safety, Unit, Water, Combination, Heaters, Shower, Heating, Tankless, Tankless water heating, Series safety shower amp combination unit heaters

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SN Series - Safety Shower & Combination Unit Heaters

1 SN Series - Safety Shower & Combination unit HeatersTankless water heating Solutions 2013 Keltech Incorporated729 South Grove Street, Delton, Michigan 49046 Phone: 800-999-4320 Fax: 1 of 4 This information is subject to change without notice. 2/8/2013 Emergency Fixtures Document No. 4986 Industry s Lowest Pressure Drop Through the System Copper and Brass Heat Exchanger Dual PID Temperature Controller with Full Modulating Temperature Control Capabilities Solid-State Relay Switching Three-Tier Anti-Scald Protection Patented Latent Heat Removal Independent Temperature Limit Cut-Offs Door Cut-Off Switch Controller-Locked Temperature Setting NEMA 4 Enclosure Standard 480 and 600V, 3-Phase Standard 144kw Accommodates Two Combination Units Activated SimultaneouslyStandard EquipmentTankless water heating SpecificationsKeltech, Inc. tankless Shower Heaters provide warm water intended to supply Safety fixtures, with no neutral required (no transformer needed).

2 The Heaters uniquely accommodate applications with low line pressure, while still accommodating ANSI standard flow rates. The durable components withstand higher pressures which result in a longer service life, while ensuring the delivery of precise output temperature. Keltech s durable components withstand power abnormalities found in industrial environments and ensure tepid water standards are never exceeded (100F), with its three-tier anti-scald protection and hot water tankless systems do not require the installation of an emergency thermostatic mixing valve. The door cut-off switch disables the unit and minimizes live components should unit internals be accessed without terminating electrical service. The NEMA 4 Enclosure (General Area) is durable and waterproof. NEMA 4X Enclosure offers the same features as a NEMA 4 enclosure, with corrosion Delivery TemperatureFactory set at 80 F, not field (kW)VoltageAmperage364804336600355448065 5460052634807663600617248087726006910848 0132108600104126480152126600121144480174 144600139 Electrical Specifications for the Heater 2013 Keltech Incorporated729 South Grove Street, Delton, Michigan 49046 Phone: 800-999-4320 Fax: 2 of 4 This information is subject to change without notice.

3 2/8/2013 Emergency Fixtures Document No. 4986SN Series - Safety Shower & Combination unit HeatersTankless water heating SolutionskWGPM23456789101215202530354036 T F1228262504036302724201612----54 T F-12393756054454137312518----63 T F-1431088672625448433629221714--72 T F--12410080726054494132242016--108 T F---15012010890827467493629242118126 T F----143122107958678574334282421144 T F-----1441201099882654939332824 water Flow and Maximum Temperature Rise by kW20151050 PSI DropGPM5010152025354030SN Pressure Drop Advantage Sizing for the proper flow rate is important. If the temperature rise capabilities of the heater is not sufficient, please contact Keltech for additional product information. 2013 Keltech Incorporated729 South Grove Street, Delton, Michigan 49046 Phone: 800-999-4320 Fax: 3 of 4 This information is subject to change without notice. 2/8/2013 Emergency Fixtures Document No. 4986SN Series - Safety Shower & Combination unit HeatersTankless water heating Solutions Keltech tankless water Heaters are non-cancelable, non-refundable and Product - SN Series36kW Safety Shower Heaters SN363/480D Three Phase 36kW, 480V Safety Shower Heater SN363/600D Three Phase 36kW, 600V Safety Shower Heater54kW Safety Shower Heaters SN563/480D Three Phase 54kW, 480V Safety Shower Heater SN563/600D Three Phase 54kW, 600V Safety Shower Heater63kW Safety Shower Heaters SN633/480D Three Phase 63kW, 480V Safety Shower Heater SN633/600D Three Phase 63kW, 600V Safety Shower Heater72kW Safety Shower Heaters SN723/480D Three Phase 72kW, 480V Safety Shower Heater SN723/600D Three Phase 72kW, 600V Safety Shower Heater108kW Safety Shower Heaters SN1083/480D Three Phase 108kW, 480V Safety Shower Heater SN1083/600D Three Phase 108kW.

4 600V Safety Shower Heater144kW Safety Shower Heaters SN1443/480D Three Phase 144kW, 480V Safety Shower Heater SN1443/600D Three Phase 144kW, 600V Safety Shower HeaterProduct Options AL3 Distributed Control System Link and 500VA Transformer AL3-SL Stack Light with Distributed Control System Link and 500VA Transformer ENHT Freeze Protection to -20 F ENHT30 Freeze Protection to -30 F EXP2 Explosion Proof Class1/Division2 FDS Fuse Disconnect GF Ground Fault Package HLW ASME Heat Exchanger (63kW and Higher Only) N4X NEMA-4X Enclosure - Stainless SteelSN / D- - - - - - - - Model Number ConfigurationApplication Attributes (MANDATORY)Coldest area ground water temperature: Minimum Flow: Maximum Flow: Set point temperature: List applicable option codes Signoff Delta T CalculationSet Point Temperature - Coldest Incoming water Temperature = Minimum Delta T for Application Verify ASME Code applicability for all installations 58kw (200,000 btu) and higher.

5 2013 Keltech Incorporated729 South Grove Street, Delton, Michigan 49046 Phone: 800-999-4320 Fax: 4 of 4 This information is subject to change without notice. 2/8/2013 Emergency Fixtures Document No. 4986SN Series - Safety Shower & Combination unit HeatersTankless water heating SolutionsSN Series - DimensionsDim. "A"Dim. "B"Dim. "C"Dim. "D"Dim. "E"Dim. "F"Dim. "G"36kW24" (610) " (86)10 " (275)16" (406)31 " (794)60" (1524)48" (1219)54kW24" (610) " (86)10 " (275)16" (406)31 " (794)60" (1524)48" (1219)63kW24" (610) " (86)10 " (275)16" (406)31 " (794)72" (1829)60" (1524)72kW30" (762) " (97)10 " (275) 22" (559)39 " (1010)60" (1524)48" (1219)108kW30" (762) " (97)10 " (275) 22" (559)39 " (1010)60" (1524)48" (1219)126kW30" (762) " (97)10 " (275) 22" (559)39 " (1010)72" (1829)60" (1524)144kW30" (762) " (97)10 " (275) 22" (559)39 " (1010)72" (1829)60" (1524) +6" (152) for fuse disconnect and freeze protection options +2" (51) for fuse disconnect and freeze protection optionsBACDEFG4"(102)27" (686)1" NPTF1" NPTFO utletDump OutletSuggested Location For Power Entrance.

6 Entrance Holes To Be Provided By Relief ValveOutlet1" NPFT ConnectionThreaded UnionsInlet"Y" StrainerTo DrainThreaded UnionHeat Dump(mm)