1 MAESTRO CONTROLS Smart DimmersAccessory DimmersHave Questions? Call the Lutron Hotline 800-523-9466 To order Call Lutron Customer Service 610-282-3800 JOB NAMEAREA CONTROLLEDLOCATIONJOB NUMBERTITLEPAGE SUBMITTALPRODUCT FAMILY FEATURES High-tech Smart Dimmer with microprocessor technology for a standard designer wallplate opening Features a clean, flush, stylish appearance Two taps on the switch brings lights on to fullbrightness; press and hold the switch to slowly fadelights to off over 10 seconds LED s indicate light level and glow softly as a locatorlight in the dark Multi-location dimming from up to 10 locations Uses standard single-pole and 3-way wiring for easyinstallation in any home Raise from offSPECIFICATION FEATURES Power- failure memory Frequency compensation Includes Radio Frequency Interference suppression Front accessible service switch (FASSTM) to disconnect load power Electrostatic discharge tested Precise color matching across all controlsThe High-Tech Multi-Location DimmerSmart DimmerSwitchRocker SwitchJacks Ports Custom Multigang Wallplates15A Receptacle15A GFCIR eceptacleSingle Telephone JackCable TV Jack2-gang to 6-gang wallplates6-Port Frame20A Receptacle20A GFCIR eceptacle Satin tap on to selected lightlevel/off; two taps full bright.

1 MAESTRO CONTROLS Smart Dimmers Accessory Dimmers Have Questions? Call the Lutron Hotline 800-523-9466 To order—Call Lutron Customer Service 610-282-3800

Tags:

  Specification, Saint, Color, Submittal, Specification submittal satin colors

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SPECIFICATION SUBMITTAL Satin Colors …

1 1 MAESTRO CONTROLS Smart DimmersAccessory DimmersHave Questions? Call the Lutron Hotline 800-523-9466 To order Call Lutron Customer Service 610-282-3800 JOB NAMEAREA CONTROLLEDLOCATIONJOB NUMBERTITLEPAGE SUBMITTALPRODUCT FAMILY FEATURES High-tech Smart Dimmer with microprocessor technology for a standard designer wallplate opening Features a clean, flush, stylish appearance Two taps on the switch brings lights on to fullbrightness; press and hold the switch to slowly fadelights to off over 10 seconds LED s indicate light level and glow softly as a locatorlight in the dark Multi-location dimming from up to 10 locations Uses standard single-pole and 3-way wiring for easyinstallation in any home Raise from offSPECIFICATION FEATURES Power- failure memory Frequency compensation Includes Radio Frequency Interference suppression Front accessible service switch (FASSTM) to disconnect load power Electrostatic discharge tested Precise color matching across all controlsThe High-Tech Multi-Location DimmerSmart DimmerSwitchRocker SwitchJacks Ports Custom Multigang Wallplates15A Receptacle15A GFCIR eceptacleSingle Telephone JackCable TV Jack2-gang to 6-gang wallplates6-Port Frame20A Receptacle20A GFCIR eceptacle Satin tap on to selected lightlevel/off; two taps full bright.

2 Press & hold for 10-second fade offPress rocker to adjust light levelFront accessible service switch(FASSTM)LED S indicate light level,glow softly Satin color ACCESSORIESNote: For multi-location dimming only-use one SmartDimmer (left) with up to nine Accessory DimmersReceptacles2 Have Questions? Call the Lutron Hotline 800-523-9466 To order Call Lutron Customer Service 610-282-3800 DescriptionModel #SMART DIMMERS IncandescentPreset Smart Dimmers Single Pole/Multi-Location600 WMSC-600M-Single Pole/Multi-Location1000 WMSC-1000M-Products above:For multi-location dimming, use one Maestro Smart Dimmer with up to nineAccessory Dimmers, MSC-AD-. Not for use with mechanical 3-way or 4-way switches. Minimumload on dimmer is 40W. Derating required if ganged, see page Low Voltage Preset Smart Dimmers Single Pole/Multi-location 600 WMSCELV-600M-Products above:For multi-location dimming, use one Maestro Smart Dimmer with to nineAccessory Dimmers, MSC-AD.

3 Requires neutral wire connection. Not for use with mechanical 3-way or 4-way switches. Minimum load on dimmer is 5W. Derating required if ganged, see page Low VoltagePreset Smart Dimmers Single Pole/Multi-Location 600VA (450W 1)MSCLV-600M-Single Pole/Multi-Location1000VA (800W 1)MSCLV-1000M-Products Above:For Multi-location dimming, use one Maestro Smart Dimmer with up to nineAccessory Dimmers, MSC-AD-. Not for use with mechanical 3-way or 4-way switches. Minimumload on dimmer is 40W. Derating required if ganged, see page control of fluorescent loads, use Lutron Hi-lume , Eco 10 TMline voltage, or Tu-Wire electronic dimming ballasts with MSC-600M- and Hi-Power 2 4 6 dimming 2 4 6 TMDIMMING MODULES To increase load capacity up to 30,000W/VA in most popular sources, use one MSC-600M- andadd up to five dimming DIMMERS Provide Multi-Location Dimming from up to Nine Additional DimmersAccessory Dimmers MSC-AD-For multi-location dimming, use up to nine Accessory Dimmers with only one of the followingMaestro multi-location dimmers: MSC-600M-, MSC-1000M-, MSCELV-600M-, MSCLV-600M-, orMSCLV-1000M.

4 No derating required if ganged. Maximum traveler wiring run for multi-locationapplications is 250 ( ). Satin Actual lamp Questions? Call the Lutron Hotline 800-523-9466 To order Call Lutron Customer Service 610-282-3800 Satin #SWITCHES General Purpose Switching of all Lighting Sources and Motor Loads Single Pole, 120/277V15 ASC-1PS-3-way, 120/277V15 ASC-3PS-4-way,120/277V15 ASC-4PS-Products above: No derating required if Receptacle 15A,125V SCR-15-20A,125V SCR-20-GFCI Receptacle 15A,125 VSCR-15-GFCI-20A,125 VSCR-20-GFCI-*Products above: No derating required if ganged.*20 Amp GFCI receptacles offered in SW, MN, TP, BI, ES, LS and DS JacksA physical barrier (partition) must exist when gangling with line-voltage productsSingle Telephone Jack 6-conductor, RJ11 SC-PJ-Note: Also accepts most 4-conductor plugsSingle Cable Jack 1F-style 75-Ohm, coaxial cable SC-CJ-No derating required if Customizable Multi-Port Frame6-Port FrameShipped with 6 blanks SC-6PF-Shown with blanksProduct above: For use with Lutron connectors shown below.

5 Also compatible with HubbleXceleratorTMand snap-fit For use with 6-port frame (SC-6PF-). Each connector fills one Jack6-conductor, RJ11, Category 3 CON-1P-C3-WHPhone Jack8-conductor, RJ45, Category 5eCON-1P-C5E-WHPhone Jack8-conductor, RJ45, Category 6 CON-1P-C6-WHFiber Jack MT-RJ Feed-Through CON-1F-MTRJ-WHFiber Jack SC SimplexCON-1F-SC-WHFiber Jack LC Non-Flush MountCON-1F-LC-WHFiber Jack ST StyleCON-1F-ST-WHCable JackF-Style, 75-Ohm Coaxial cableCON-1C-WHBNC JackBNC connectorCON-1B-WHConnectors available in white (WH) only. For information about additional Colors contact LutronCustomer Questions? Call the Lutron Hotline 800-523-9466 To order Call Lutron Customer Service 610-282-3800 Satin #STANDARD WALLPLATES 1-Gang W: (75mm) x H: (119mm) x D: ( )SC-1-2-GangW: (121mm) x H: (119mm) x D: ( )SC-2-3-GangW: (167mm) x H: (119mm) x D: ( )SC-3-4-GangW: (213mm) x H: (119mm) x D: ( )SC-4-5-GangW: (259mm) x H: (119mm) x D: ( )SC-5-6-GangW: (305mm) x H: (119mm) x D: ( )SC-6-STANDARD Colors /FINISHESM atte Finishes (Ships in 48 hours)Add color /finish suffix to model number to.

6 MSC-600M-SWClassicoTMSWSnowBIBiscuitESEg gshellTPTaupeMNMidnightLustraTMBTBlue MistPiedraTMLSL imestoneSTStoneDSDesert StoneTCTerracottaVibratoTMHTHotOCOchre5 DERATING/MAXIMUM CAPACITYI ncandescent Dimmers 1600W500W400W1000W800W650 WElectronic Low Voltage 2600W500W400 WMagnetic Low Voltage 1600VA500VA400VA(450W 2)(400W 3)(300W 2)1000VA800VA650VA(800W 2)(650W 3)(500W 2) Satin side sections removed(Full Capacity)One side section removed(End Units) Two side sections removed (End Units) Have Questions? Call the Lutron Hotline 800-523-9466 To order Call Lutron Customer Service 610-282-38001 Requires 40W minimum Requires 5W minimum Actual lamp "(119mm) "(75mm) " ( ) "(70mm) " (37mm)DIMENSIONSI ncluding Satin Colors wallplates Wallplates sold Questions? Call the Lutron Hotline 800-523-9466 To order Call Lutron Customer Service 610-282-3800 Wiring Diagram 2 Multi-Location WiringModel # MSC-AD-MSC-600M-MSC-1000M-MSC-600M-MSC-1 000M-ORControl Line SideNeutralRedBlueMulti-LocationDimmerSm art RemoteSmart RemoteSmart RemoteBlackBlackHotUp to Nine Total Auxiliary Switches/Remotes120 VAC60 HzGreenGreenGreenGreenBlueRedBlackBlueRe dBlackBlueLighting LoadRedGrouWireSmart RemoteSmart RemoteSmart RemoteUp to Nine Total Auxiliary Switches /RemotesGreenGreenGreenGreenNeutralBlack BlueMulti-LocationDimmerRedRedHot120 VAC60 HzBlueBlackRedBlueBlackRedBlueLighting LoadBlackControl Load SideGroundWire ConnectorsGroundWire ConnectorsWIRING DIAGRAMSW iring Diagram 1 Single-Location WiringModel # MSC-600M-MSC-1000M-MSC-600M-MSC-1000M- Satin BlackRedBlueCap OffLightingLoad NeutralHot120 VAC60 HzGroundWire Connectors7 Have Questions?

7 Call the Lutron Hotline 800-523-9466 To order Call Lutron Customer Service 610-282-3800 Satin Diagram 6 Telephone Jack WiringModel # SC-PJ-Wiring Diagram 7 Receptacle WiringModel # SCR-15-SCR-20-Wiring Diagram 8 GFCI Receptacle WiringModel # SCR-15-GFCI-SCR-20-GFCI-WIRING DIAGRAMSW iring Diagram 4 Multi-Location Control with Neutral Used for Single-Location Wiring Model # MSCELV-600M-Wiring Diagram 5 Multi-Location Wiring Model # MSCELV-600M-MSC-AD-GroundNeutralHotBlack WhiteGreen or Screw TerminalGreen or Screw TerminalGreen or Screw TerminalBlackWhite120 VAC60 HzGFCIR eceptacle(15A Shown)NPNPPPPPLineLoadWire ConnectorsP-ProtectedNP-Not ProtectedBuilding Ground(To Metal Box)SmartRemoteMulti-Location DimmerGreenGreenLighting LoadNeutralBlackBlueWhiteBlackRedYellowH ot120 VAC60 HzBlueUp to Nine Total MSC-AD- UnitsControl Load SideGroundWire ConnectorsNeutralGreenBlackDimmer/TapSwi tchYellowBlueHot120 VAC60 HzLighting LoadWhiteCap OffGroundWire Connectors6-ConductorTelephone Jack*WireColorJack Position1 White2 Black3 Red4 Green5 Yellow6 Blue* accepts most 4-conductor jacksNeutralBlackReceptacle (15A Shown)WhiteHot120 VAC60 HzNickel Plated ScrewsBrassScrewsGreenScrew Ground orIsolated GroundGroundWire EQUIPMENT A.

8 Controls Lutron Maestro Style 1. Performance a. Dimmers shall provide full-range, smooth andcontinuously variable control of light All dimmers shall be designed to minimizeeffects of changing line An actuator, accessible from the front of theunit, with the wallplate attached, shall activatea mechanical air-gap switch disconnectingpower from the load during "safety off"condition; no leakage current shall be presentat the fixture(s). This front accessible safetyswitch (FASS ) shall be separate from thetapswitch and raise/lower Dimmer shall be capable of on/off, raise/lowerand mechanical air-gap "safety off" from up to 9 additional locations using aestheticallycoordinated Controls shall meet ANSI/IEEE Std. , tested to withstand voltage surges of upto 4000V and current surges of up to 200 Awithout Controls shall not be susceptible to damage or loss of memory due to static Controls shall be capable of operating at therated capacity; this includes modifiedcapacities for ganging configurations whichrequire the removal of fins.

9 Operation at ratedcapacity shall be possible across the fullambient temperature range, without shorteningdesign Controls shall operate in an ambienttemperature range of 0 C (32 F) to 40 C(104 F).i. Controls shall incorporate power-failurememory. Should power be interrupted andsubsequently returned, the lights will comeback on to the same levels set prior to thepower interruption. Restoration to some otherdefault level is not Dimmers shall be designed to reduceinterference with radio, audio, and To ensure a precise color match between allplastic parts, color variation of any gloss partshall not exceed a just noticeable level, delta Eof 1, as defined in ASTM E Visible parts of dimmers, switches, standardreceptacles, cable jacks or any wallplate shallexhibit ultraviolet stability when tested asdefined in ASTM All actuators shall be captured internally to the CONTROLS AND ACCESSORIESPART 1 GENERAL SUMMARY A. Scope: Provide, install and test all switches, dimmersand related devices as specified herein for the areasindicated on the drawings, specifications, and Related Sections: Section 16580 (Ballasts), Section16570 (Dimming Systems).

10 REFERENCES A. UL 1472, CSA, NOM, ISO 9001 SYSTEM DESCRIPTION AND OPERATION A. Permanently installed, wallbox mounted switches and dimmers B. Permanently installed, wallbox mounted receptacles C. Permanently installed, wallbox mounted data, voiceand cable jacks D. Screwless, seamless wallplates SUBMITTALS A. Submit manufacturer's standard catalog data givingall application, wiring, and installation information on basic components and wallplate Provide test data and/or samples as required todemonstrate conformance with PART 2 of QUALITY ASSURANCE A. Manufacturer shall have a minimum of 10 yearscontinuous experience in manufacturing wallboxdimming Dimmers shall be UL listed, CSA and NOM approvedspecifically for each required load ( , tungsten,electronic low voltage transformer, and magnetic lowvoltage transformer). Manufacturer shall provide filecard or certificate upon request. Universal load-typedimmers shall not be Manufacturer shall maintain ISO 9001 certificationand provide a copy of the certificate upon WARRANTY A.