SPECIFICATIONS - Temperzone

ModelOPA 550 RKTBG-P ECOC onfigurationHorizontal Supply AirItem No. (Standard / Opposite Hand)866-055-701 / 866-055-710 Unit c/w Fresh Air Cowl (OPA 550 RKTBG-PC)868-055-701 / 868-055-710 Cooling capacity (net) to AS/NZS 3823 kWHeating capacity kWElectrical input - kWElectrical input - kWEER / AEER (cooling) / COP / ACOP (heating) / ControllerUC8 (x2)RefrigerantR410 ARefrigerant oil type POE 32-3 MAF (or equivalent)Compressor typedigital + fixed scrollPower supply3 ph. 400V ac 50 HzCompressor (3ph.) run amps at rating A/ph. (x2)Compressor overload setting17 / 17 ACompressor circuit breaker32 A (x2)Indoor fan motor sizeEC plug 560 dia. air flow at rating conditions2800 l/sIndoor fan motor (3ph.) - full load6 fan motor (1ph.) - full A (x2)Outdoor fan capacitor sizen/aControl circuit breaker (internal)2 AAuxilary power outlet (1ph.)

PROJECTION Not to Scale OPA 550RKTBG01-P(C) Standard Hand DIMENSIONS (mm) NOTE Specifications are subject to change without notice …

Tags:

  Specification

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SPECIFICATIONS - Temperzone

1 ModelOPA 550 RKTBG-P ECOC onfigurationHorizontal Supply AirItem No. (Standard / Opposite Hand)866-055-701 / 866-055-710 Unit c/w Fresh Air Cowl (OPA 550 RKTBG-PC)868-055-701 / 868-055-710 Cooling capacity (net) to AS/NZS 3823 kWHeating capacity kWElectrical input - kWElectrical input - kWEER / AEER (cooling) / COP / ACOP (heating) / ControllerUC8 (x2)RefrigerantR410 ARefrigerant oil type POE 32-3 MAF (or equivalent)Compressor typedigital + fixed scrollPower supply3 ph. 400V ac 50 HzCompressor (3ph.) run amps at rating A/ph. (x2)Compressor overload setting17 / 17 ACompressor circuit breaker32 A (x2)Indoor fan motor sizeEC plug 560 dia. air flow at rating conditions2800 l/sIndoor fan motor (3ph.) - full load6 fan motor (1ph.) - full A (x2)Outdoor fan capacitor sizen/aControl circuit breaker (internal)2 AAuxilary power outlet (1ph.)

2 Overload setting10 ARunning amps (total system)29 / 38 / 29 AMax. running amps (total system)36 / 46 / 37 ANet weight878 kgWeight c/w Fresh Air Cowl option913 kgAccessories:Filters - rated EU4/G4 disposable019-400-010 450x600x50 (x2)019-400-007 600x600x50 (x2)Optional Controls:TZT-100 Room temperature controller201-000-350 Refer to Temperzone for other in accordance with AS/NZS 382316120 SPECIFICATIONSPROJECTIONNot to ScaleOPA 550 RKTBG01-P(C) Standard HandDIMENSIONS (mm)NOTE SPECIFICATIONS are subject to change without notice due to the manufacturer's ongoing research and development 550 RKTBG10-P(C) Opposite HandElectricalAccessUVSUPPLYAIRRETURNAIR WF ilter AccessDrain 25 ID BSP female500 MIN. CLEARANCE1000 MIN. CLEARANCE1000 MIN. CLEARANCEXZFan AccessY2000 MIN. CLEARANCE1793 O/D800 MIN. CLEARANCE TO UNITO ptionalFresh AirCowlOptionalFresh AirCowlElectricalAccessUVSUPPLYAIRRETURN AIRWF ilter AccessDrain 25 ID BSP female500 MIN.

3 CLEARANCE1000 MIN. CLEARANCE2000 MIN. CLEARANCE1000 MIN. CLEARANCEXZYFan Access1793 O/DOptionalFresh AirCowl800 MIN. CLEARANCE TO UNITO ptionalFresh AirCowl430335 POINT LOADS (kg)UV WXYZno F/A158143127139150161cw F/A164155137142153162 POINT LOADS (kg)UV WXYZno F/A161150139127143158cw F/A162153142137155164 WIRINGD rawn:Apprvd:Title:Drawing No:Rev:Date: Temperzone Ltd 2016DO NOTSCALE - ASKC lient WiringSHEET OF21C291-002-163 Wiring SchematicOPA 550 RKTBG-P 224 VCOMP 124 VTB9 HEAT24 VTRCMCB1 OFCBCMC124 VCBM3~CMM1 ETH1 Sensors and Transducer*Refer TableCMC1N/CCOMN/OFRB1 CCBSPSCMOL1 APPROVEDDATEECNDESCRIPTIONREVAI nitial ReleaseBBusbar symbols updated to L1 L2 terminal links moved to Contacts Moved & Earth Moved & PLRC Added To TableRemote On/Off optionIf Remote On/Off optionfitted remove this linkFor Client Wiring to Terminal Blocks & Descriptions, Refer Sheet 2 CMCB2 CMC 2M3~CMM2 CMOL2 CMC2N/CCOMN/OFRB2 Modbus port for BMS(monitoring or control)Ref Sheet 20-10 VID FAN0 VID FANTB7 SYS 2 FAULTSYS 1 FAULTCOMFAULTID FANFAULT0-10 VCOMP 1TB60 VCOMP 1C9-BD9-CP1-CM1-CK5-E5-EJModbus masterport for optionalT/stat(SAT-3/TZT100)TJ2W1 CCH1TJ2W2RV1TJ3W1TJ2W5 CCH2TJ2W6RV2TJ3W2W1-DX1-E(No.)

4 1)A9-AB9-A(No. 2)IFCAA6-FAA3-GIBB1 IFCBIFCMISAL3-DAB1-BETH1K8-EJ8-EM2-E,6-E M1-CP6-ER5-F,8-ER1-CS1-ES1-ET1-ET1-EU1-E U1-EV3-D,7-DW3-DX7-DV1-DV1-DG6-FD1D2Y5-F Z9-FY1-D1-DZN2-EN1-CTB15ID FANFAULT COMAG4-EAJ8-EAJ6-EL2L3L1AB6-BAL1-BPressu resensorsTemp Sensors(Refer to table)UC8 HPTLPTAMB0VA1B10VA2B212 FLTD2D1SC0V0VV20VV1D3 ONEOCICDEIDLSLAUXMEEXV1 EXV2IN#2IN#2IN#1IN#1C2 HTCPC1 HILOCMCSSR2 SSR2 SSR1 SSR1R/VR/VCMCC3 LOWMEDHIGHNLJ1J2C40 VVF50 VVC12DP1SW3SW1SW2 Refer to DIP S/W settingsDisplayAF4-E1-BAFP ressuresensorsTemp Sensors(Refer to table)UC8 HPTLPTAMB0VA1B10VA2B212 FLTD2D1SC0V0VV20VV1D3 ONEOCICDEIDLSLAUXMEEXV1 EXV2IN#2IN#2IN#1IN#1C2 HTCPC1 HILOCMCSSR2 SSR2 SSR1 SSR1R/VR/VCMCC3 LOWMEDHIGHNLJ1J2C40 VVF50 VVC12DP1SW3SW1SW2 Refer to DIP S/W settingsDisplayG2-FAG1-BRemoteOn/Off optionIf Remote On/Off optionfitted remove this linkMVM3~IFM1 CBL1 CBL1AK0-DR1-CL1-B8-ELAI1-C8-EAI 230 VMAINSTFC FANoutputFor SW2 (DIP switch) settings- Refer tableTFC2 ETH2 CAP2 230 VMAINSTFC FANoutputFor SW2 (DIP switch) settings- Refer tableTFC1 ETH2A4-F4-FBCAP1 FAN 4 FAN 3TB12 FAN 2 FAN 1N5TB11N49-FCD9-FOFM1 OFM2 HIGH IN24 VMED IN24 VTB10 LOW IN24 VTB824 VCOM24 VCOM24 VETH1S3-E,7-ET3-E,7-EU3-E,7-ETB16 CCHNNNAC2-A0-EACCMOL1 CMOL2 EEV1 EEV2 EEV3 EEV4 PLRSPSCBPFC1 PFC2 CarelCarelL1L1L1L1L2L2L2L2L3L3L3L3AK8-DP LRCCCCC Temperzone limited 2018003-000-081 05 :Apprvd:Title:Drawing No:Rev:Date.

5 Temperzone Ltd 2016DO NOTSCALE - ASKC lient WiringSHEET OF22C291-002-163 Wiring SchematicOPA 550 RKTBG-P ReleaseBBusbar symbols updated to L1 L2 L3. Client CB and MIS Breaker & Isolator Switch Added & PLRC Added To ) Crankcase Heater Note24 Hour power required for controlcircuit and crankcase heatersImportant Notes:Sensors (S) / Transducers (T)NameTypeColourDLDischarge TempSREDSLS uction TempSWHITEAMBA mbient TempSBLACKDEIDe-ice TempSBLUELPTS uction PressureTHPTHigh PressureTSAT-3 & TZT100 connection to UC8 terminalsUC8 terminals( )SAT-3 TZT100 Terminals1212V24B2 BBA2AA0 VGND24 CTB3 NTB4TB2 NTB1 NTB5 Client Wiring{MODBUS port for BMSBMS ControlTFC DIP switch settingsDIP switchOn/Off-On1, 2, 3, 4 OffRemote On/Off option0 VONIf Remote On/Off optionfitted remove this linkScreen to 0 VRemote option2) SAT-3 & TZT 100 NoteTo connect TZT100 to unit use 2pair twisted cable - screengrounded.}

6 (F/UTP 24G ( )or thicker recommended)UC8 DIP switch settings ( )DIP switchOn/Off1,2,4,6,7,10 OnAll Others OffOffUC8 DIP switch settings ( )DIP switchOn/Off1,4,6,7,10 OnAll Others OffOff24 VCB 24 VOLT CIRCUIT BREAKERCAP CAPACITORCBL CABLECCB CONTROL CIRCUIT BREAKERCCH CRANKCASE HEATERCMC COMPRESSOR CONTACTORCMCB COMPRESSOR CIRCUIT BREAKERCMM COMPRESSOR MOTORCMOL COMPRESSOR OVERLOADEEV ELECTRONIC EXPANSION VALVEETH EARTHFRB FAULT RELAY BOARDIFC INDOOR FAN CONTACTORIFCB INDOOR FAN CIRCUIT BREAKERIFM INDOOR FAN MOTORIBB INSULATED BUS BARMIS MAIN ISOLATOR SWITCHMV MODULATING VALVEOFCB OUTDOOR FAN CIRCUIT BREAKEROFM OUTDOOR FAN MOTORPFC POWER FACTOR CORRECTIONPLR PHASE LOSS RELAYPLRC PHASE LOSS RELAY CONTACTRV REVERSING VALVESPS SINGLE PHASE SOCKETSPSCB SINGLE PHASE SOCKET CIRCUIT BREAKERTB TERMINAL BLOCKTFC TRIAC FAN CONTROLLERTJ TERMINAL JOINERTR TRANSFORMERUC8 UNIT CONTROLLER 8L1 IBB1 L1 LINE SUPPLYL2 IBB1 L2 LINE SUPPLYL3 IBB1 L3 LINE SUPPLY3)

7 Master-slave noteWhen the unit is controlled with aTZT-100 or SAT-3 wall thermostatthen the two UC8 controllers must belinked and configured as master DIP switch settings: 11 OFF 12 OFFS lave DIP switch settings: 11 ON 12 OFFL3L2L1 Client Protection andIsolator SwitchCCCLIENT WIRINGR efer 'Installation & Maintenance' pamphlet for more information.