Transcription of STOARMAT RENDER SYSTEM EXT.CORNER - …
1 STOARMAT RENDER . SYSTEM . 20mm DRAINED CAVITY. REBATED FC. SHEET. WALL UNDERLAY CONTINUOUS. AROUND CORNERS, POLYPROPYLENE FLASHING TAPE. APPLIED TO PROTECT WALL. UNDERLAY 75mm TIMBER FRAMING. TO NZS 3604. STO uPVC CLIP. ON FLASHING. MS SEALANT ON. pef rod . SEALANT TO. JUNCTION. PROPRIETARY CLADDING FIXED ACCORDING. TO DETAILS. NOTE: FINISH STO CLADDING SYSTEM BEFORE. INSTALLING STONE CLADDING. SCALE 1:2. STO/ STOARMAT RENDER SYSTEM FCS 840. MONOTEK. - SHEET 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site.
2 TIMBER FRAMING. TO NZS 3604. WALL UNDERLAY. CONTINUOUS AROUND. CORNERS. E2/AS1 COMPLIANT. BACK FLASHING. PROPRIETARY STONE VENEER CLADDING. FIXED ACCORDING TO. DETAILS. STO PREMESHED PVC. ON ALL. 20mm DRAINED CAVITY 2mm GAP BETWEEN. REBATED SHEET SHEETS. STOARMAT RENDER . SYSTEM WITH STO uPVC. CLIP ON TRAY or FINISHING. EDGE. SCALE 1:2. STO/ STOARMAT RENDER SYSTEM FCS 841. MONOTEK. BOXED - STONE VENEER/FC SHEET 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site.
3 WALL UNDERLAY CONTINUOUS. AROUND CORNERS. STOARMAT RENDER SYSTEM . 20mm DRAINED CAVITY. REBATED FC SHEET. STO uPVC CLIP ON TRAY. MS SEALANT ON pef rod . PROPRIETARY CLADDING. FIXED ACCORDING TO. DETAILS. 8. E2/AS1 COMPLIANT 50x50mm CORNER FLASHING. 8mm BETWEEN SHEETS, MS. SEALANT JOINT. TIMBER FRAMING. TO NZS 3604. DOUBLE STUD REQUIRED. NOTE: INSTALL FC SHEET AND FINISH STO. CLADDING SYSTEM BEFORE INSTALLING STONE. SCALE 1:2. STO/ STOARMAT RENDER SYSTEM FCS 842. MONOTEK. INTERNAL CORNER - SHEET 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site.
4 50mm MIN. 50mm MIN. COVER COVER. E2/AS1 COMPLIANT. BACK FLASHING. 20mm DRAINED CAVITY. REBATED SHEET. STOARMAT RENDER . SYSTEM WITH STO uPVC. CLIP ON TRAY. PROPRIETARY CLADDING. OVER FIXED ACCORDING TO. DETAILS. MS SEALANT ON pef rod . SCALE 1:2. STO/ STOARMAT RENDER SYSTEM FCS 843. MONOTEK. VERTICAL JUNCTION - SHEET 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site.
5 20mm DRAINED. CAVITY. REBATED. FC SHEET. STOARMAT RENDER . SYSTEM . WALL UNDERLAY. CONTINUOUS AROUND. TIMBER FRAMING CONERS,POLY. TO NZS 3604 PROPYLENE FLASHING. TAPE APPLIED TO. PROTECT WALL. UNDERLAY 75mm INSTALL FC SHEET AND. FINISH STOARMAT . CLADDING SYSTEM . BEFORE INSTALLING. SCHIST OR STONE. STO uPVC CLIP. ON FLASHING. MS SEALANT/STO. SEAL TAPE. MS SEALANT ON pef rod . or STO JOINT SEAL TAPE. SCHIST OR STONE VENEER CLADDING. FIXED ACCORDING TO. DETAILS. SCALE 1:2. STO/ STOARMAT RENDER SYSTEM FCS 844. MONOTEK. - SCHIST or STONE VENEER/FC SHEET 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems.
6 Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site. STOARMAT RENDER . SYSTEM . REBATED FC SHEET. 20mm DRAINED CAVITY. WALL UNDERLAY CONTINUOUS. AROUND CORNERS. MS SEALANT ON pef rod or STO. JOINT SEAL TAPE. SCHIST OR STONE VENEER CLADDING AN. FIXED ACCORDING TO. DETAILS. 50mm MIN. 8. 8mm BETWEEN. SHEETS, MS SEALANT. E2/AS1 COMPLIANT BACK FLASHING. WITH 50mm MIN. COVER TO. CLADDING. TIMBER FRAMING. TO NZS 3604. DOUBLE STUD REQUIRED. NOTE: INSTALL FC SHEET AND FINISH STO. CLADDING SYSTEM BEFORE INSTALLING STONE. SCALE 1:2. STO/ STOARMAT RENDER SYSTEM FCS 845. MONOTEK. - SCHIST or STONE VENEER/FC SHEET 2017.
7 The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site. 50mm COVER 50mm COVER. MS SEALANT ON pef rod . E2/AS1 COMPLIANT BACK FLASHING. WITH 50mm COVER. CAVITY BATTENS. REBATED SHEET. STOARMAT . RENDER SYSTEM . STO uPVC CLIP ON. FLASHING. SCHIST OR STONE VENEER. CLADDING FIXED ACCORDING TO. DETAILS. SCALE 1:2. STO/ STOARMAT RENDER SYSTEM FCS 846.
8 MONOTEK. VERTICAL JUNCTION - SCHIST or STONE VENEER/FC SHEET 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site. 20mm DRAINED CAVITY. REBATED FC. SHEET. STOARMAT RENDER SYSTEM . TAPE OVER FLASHING. VERMIN TRAY - BY OTHERS. STO uPVC CLIP ON FLASHING. COVER. 35mm NOTE: 10mm GAP. SCHIST OR STONE VENEER. CLADDING FIXED ACCORDING TO. DETAILS.
9 TOP PIECE OF SCHIST OR STONE. MUST EITHER BE PLACED OR CUT SO. A 15 SLOPE IS FORMED ON THE SILL. SCALE 1:2. STO/ STOARMAT RENDER SYSTEM FCS 847. MONOTEK. - SCHIST or STONE VENEER/FC SHEET 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site.