Transcription of STOLITE CONSTRUCTION SYSTEM EXT.CORNER - …
1 STOLITE RENDER SYSTEM . 20mm DRAINED CAVITY. 6mm FIBRE CEMENT SHEET. WALL UNDERLAY CONTINUOUS. AROUND CORNERS, POLYPROPYLENE FLASHING TAPE. APPLIED TO PROTECT WALL. UNDERLAY 75mm TIMBER FRAMING. TO NZS 3604. STOLITE CLIP ON. FLASHING. MS SEALANT ON. pef rod . SEALANT TO. JUNCTION. PROPRIETARY CLADDING. FIXED ACCORDINGLY TO. DETAILS. NOTE: FINISH STOLITE CLADDING SYSTEM . BEFORE INSTALLING STONE CLADDING. SCALE 1:2. STOLITE STOLITE CONSTRUCTION SYSTEM SL 840. SYSTEM . - 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems.
2 Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site. TIMBER FRAMING. TO NZS 3604. WALL UNDERLAY. CONTINUOUS AROUND. CORNERS. E2/AS1 COMPLIANT. BACK FLASHING. PROPRIETARY STONE VENEER CLADDING. FIXED ACCORDING TO. DETAILS. 20mm DRAINED CAVITY. STO PREMESHED PVC. 6mm FIBRE CEMENT SHEET ON ALL. STOLITE PLASTER SYSTEM WITH STO uPVC CLIPON. FLASHING. SCALE 1:2. STOLITE STOLITE CONSTRUCTION SYSTEM SL 841. SYSTEM . BOXED EXTERNAL CORNER - STONE VENEER/ STOLITE 2017. The information contained on this page is based on our experience and research at the date of issue.
3 The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site. WALL UNDERLAY CONTINUOUS. AROUND CORNERS. STOLITERENDER SYSTEM . 20mm DRAINED CAVITY. 6mm FIBRE CEMENT SHEET. STOLITE CLIP ON FLASHING. MS SEALANT ON pef rod . PROPRIETARY CLADDING. FIXED ACCORDING TO. DETAILS. 8. E2/AS1 COMPLIANT 50x50mm CORNER FLASHING. 8mm BETWEEN SHEETS, MS. SEALANT JOINT. TIMBER FRAMING.
4 TO NZS 3604. DOUBLE STUD REQUIRED. NOTE: INSTALL FC SHEET AND FINISH STOLITE . CLADDING SYSTEM BEFORE INSTALLING STONE. SCALE 1:2. STOLITE STOLITE CONSTRUCTION SYSTEM SL 842. SYSTEM . INTERNAL CORNER - 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site.
5 50mm MIN. 50mm MIN. COVER COVER. E2/AS1 COMPLIANT. BACK FLASHING. 20mm DRAINED CAVITY. 6mm FIBRE CEMENT SHEET. STOLITE RENDER. SYSTEM . STO uPVC CLIP ON. FLASHING PROPRIETARY CLADDING. OVER FIXED ACCORDING TO. DETAILS. MS SEALANT ON pef rod . SCALE 1:2. STOLITE STOLITE CONSTRUCTION SYSTEM SL 843. SYSTEM . VERTICAL JUNCTION - 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site.
6 20mm DRAINED. CAVITY. 6mm FIBRE. CEMENT SHEET. STOLITE RENDER. TIMBER FRAMING SYSTEM . TO NZS 3604. WALL UNDERLAY. CONTINUOUS AROUND. CONERS,POLY PROPYLENE. FLASHING TAPE APPLIED. TO PROTECT WALL. UNDERLAY 75mm INSTALL FC SHEET AND. FINISH STOLITE CLADDING. SYSTEM BEFORE. INSTALLING SCHIST OR. STONE. STOLITE CLIP ON. FLASHING. MS SEALANT ON. pef rod . SCHIST OR STONE VENEER CLADDING. FIXED ACCORDING TO. DETAILS. SCALE 1:2. STOLITE STOLITE CONSTRUCTION SYSTEM SL 844. SYSTEM . - SCHIST or STONE VENEER/ STOLITE 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems.
7 Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site. STOLITE RENDER SYSTEM . 6mm FIBRE CEMENT SHEET. 20mm DRAINED CAVITY. WALL UNDERLAY CONTINUOUS. AROUND CORNERS. MS SEALANT ON pef rod . SCHIST OR STONE VENEER CLADDING AN. FIXED ACCORDING TO. DETAILS. 50mm MIN. 8. 8mm BETWEEN. SHEETS, MS SEALANT. E2/AS1 COMPLIANT BACK FLASHING. WITH 50mm MIN. COVER TO. CLADDING. TIMBER FRAMING. TO NZS 3604. DOUBLE STUD REQUIRED. NOTE: INSTALL FC SHEET AND FINISH STOLITE . CLADDING SYSTEM BEFORE INSTALLING STONE.
8 SCALE 1:2. STOLITE STOLITE CONSTRUCTION SYSTEM SL 845. SYSTEM . - SCHIST or STONE VENEER/ STOLITE 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure they have and use the current Sto details and specifications on site. 50mm COVER 50mm COVER. MS SEALANT ON pef rod . E2/AS1 COMPLIANT BACK FLASHING. WITH 50mm COVER.
9 CAVITY BATTENS. 6mm FIBRE CEMENT SHEET. STOLITE RENDER. SYSTEM . STO uPVC CLIP ON. FLASHING. SCHIST OR STONE VENEER. CLADDING FIXED ACCORDING TO. DETAILS. SCALE 1:2. STOLITE STOLITE CONSTRUCTION SYSTEM SL 846. SYSTEM . VERTICAL JUNCTION - SCHIST or STONE VENEER/ STOLITE 2017. The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
10 20mm DRAINED CAVITY. 6mm FIBRE CEMENT SHEET. STOLITE RENDER SYSTEM . FLASHING TAPE ONTO BUILDING. UNDERLAY AND OVER COMPLIANT. METAL FLASHING. VERMIN TRAY BY. OTHERS. STOLITE uPVC CLIP. ON FLASHING. NOTE: COVER. P. 35mm m GA. SCHIST OR STONE VENEER. CLADDING FIXED ACCORDING TO. 10m DETAILS. TOP PIECE OF SCHIST OR STONE. MUST EITHER BE PLACED OR CUT SO. A 15 SLOPE IS FORMED ON THE SILL. SCALE 1:2. STOLITE STOLITE CONSTRUCTION SYSTEM SL 847. SYSTEM . - SCHIST or STONE VENEER/ STOLITE 2017. The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems.