Example: tourism industry

Systec Laboratory Autoclaves

Fotolia LayoutSystec Laboratory AutoclavesSystec H-Series. Horizontal floor-standing H-Series 2D. Pass-through Autoclaves . 2 02 Performance and countsWe only make two things. Laboratory Autoclaves and devices for the improved sterilization and handling of culture media. Always with the goal of making Laboratory work safer, easier, more accurate, reproducible and validatable, and consequently more economical. With over 20 years of experience and continuous intensive cooperation with experts and users, we know how to provide optimal solutions for even the most complex sterilization tasks. We have the knowledge and experience to produce the best results!Our expertise and know-how are available for you worldwide through specialized and specially selected partners. 3 02 Laboratory AutoclavesContentsSystec H-Series.

Fotolia Layout Systec Laboratory Autoclaves Systec H-Series. Horizontal floor-standing autoclaves. Systec H-Series 2D. Pass-through autoclaves.

Tags:

  Laboratory, Autoclaves, Systec laboratory autoclaves, Systec

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Systec Laboratory Autoclaves

1 Fotolia LayoutSystec Laboratory AutoclavesSystec H-Series. Horizontal floor-standing H-Series 2D. Pass-through Autoclaves . 2 02 Performance and countsWe only make two things. Laboratory Autoclaves and devices for the improved sterilization and handling of culture media. Always with the goal of making Laboratory work safer, easier, more accurate, reproducible and validatable, and consequently more economical. With over 20 years of experience and continuous intensive cooperation with experts and users, we know how to provide optimal solutions for even the most complex sterilization tasks. We have the knowledge and experience to produce the best results!Our expertise and know-how are available for you worldwide through specialized and specially selected partners. 3 02 Laboratory AutoclavesContentsSystec H-Series.

2 Horizontal floor-standing Autoclaves ..04 Systec H-Series 2D. Pass-through Autoclaves ..06 Performance characteristics Systec H-Series and H-Series 2D ..08 Design and Engineering ..10 Control and Documentation ..13 Processes and Applications ..16 Loading ..22 Custom Developments ..23 Qualification and Validation ..24 Sales and Service ..25 Overview ..27 The power of innovation. For better Laboratory autoclavesSpecially developed for Laboratory sterilization applications, Systec Autoclaves make processes safer, easier, accurate, reproducible and Autoclaves can be used in all Laboratory applications, even in demanding sterilization processes: the sterilization of liquids (such as nutrient and culture media), solids (such as instruments, pipettes, glassware), waste (destructive steriliza-tion of liquid waste in bottles, or solid waste in destruction bags) and biological hazards in safety laboratories.

3 4 02/2017 Systec H-Series. Horizontal floor-standing of the performance category HX can be used for all Laboratory applications, even for sophisticated sterilization processes. All additional optional accessories can be fitted to obtain validatable processes. In spite of the high loading capacity, these Autoclaves are compact and have a comparatively low models 65 to 1580 l chamber capacity 5 02/2017 Systec dimensions x depth (mm)400 x 500400 x 700500 x 500500 x 750500 x 1000 Chamber volume (l) total / nominal70 / 6595 / 90113 / 100162 / 150211 / 200 External dimensions (mm)Height14651465156515651565 Width690690790790790 Depth805100592511751425 Heating capacity (kW) weight (kg)125145250300350 Dimensions and performanceSystecHX-210HX-320HX-430HX-54 0HX-650 Chamber dimensions x depth (mm)740 x 500740 x 750740 x 1000740 x 1250740 x 1500 Chamber volume (l) total / nominal280 / 210385 / 320495 / 430602 / 540710 / 650 External dimensions (mm)

4 Height17151715171517151715 Width930930930930930 Depth10351285153517852035 Heating capacity (kW) weight (kg)450480530600660 SystecHX-580HX-780HX-980HX-1180HX-1380HX -1580 Chamber dimensions x depth (mm)1000 x 7501000 x 10001000 x 12501000 x 15001000 x 17501000 x 2000 Chamber volume (l) total / nominal746 / 580942 / 7801138 / 9801335 / 11801531 / 13801727 / 1580 External dimensions (mm)Height187518751875187518751875 Width125512551255125512551255 Depth144016901940219024402690 Heating capacity (kW) weight (kg)81085092099010501110 Electrical connections for the Systec HX-65 to HX-200: 380 400 V, 50 / 60 Hz, 16 connections for the Systec HX-210 to HX-650: 380 400 V, 50 / 60 Hz, 32 connections for the Systec HX-580 to HX-1580: 380 400 V, 50 / 60 Hz, 63 voltage available upon request.

5 6 02/2017 Systec LoadingSystec H-Series H-Series 2D. Pass-through safety aspects One door only can be opened at a time. If one door is open, the other is automatically locked. If the autoclave is switched off or if no current is available ( power failure), both doors remain locked. If the door at the non-sterile side is opened, a sterilization program has to be performed before the door at the sterile side can be locking system can be adapted to customers wishes. Doors and control panel are made of heat-insulating plastic, the housing completely of stainless steel and the stainless steel edges specially processed for smooth junctions with walls. Operation, however, can be carried out from both sides, the position (open or closed) of the opposite door being indicated on the use under the most stringent clean room and safety conditions For biological safety laboratories.

6 Fitting as a sterilization and pass-through lock for protecting the external environment. For clean rooms in laboratories and production facilities as a sterilization and pass-through lock separating sterile and non-sterile models 90 to 1580 l chamber capacity 7 02/2017 Systec LoadingSystec H-Series 2 DHX-150 2 DHX-200 2 DChamber dimensions x depth (mm)400 x 750500 x 750500 x 1000 Chamber volume (l) total / nominal101 / 90160 / 150209 / 200 Heating capacity (kW) weight (kg)250250350 Dimensions and performanceSystecHX-320 2 DHX-430 2 DHX-540 2 DHX-650 2 DChamber dimensions x depth in mm 740 x 750 740 x 1000740 x 1250740 x 1500 Chamber volume (l) total / nominal 370 / 320 480 / 430590 / 540700 / 650 Heating capacity (kW) weight (kg)520570640700 SystecHX-580 2 DHX-780 2 DHX-980 2 DHX-1180 2 DHX-1380 2 DHX-1580 2 DChamber dimensions x depth (mm)

7 1000 x 7501000 x 10001000 x 12501000 x 15001000 x 17501000 x 2000 Chamber volume (l) total / nominal 706 / 580902 / 7801098 / 9801295 / 11801491 / 13801687 / 1580 Heating capacity (kW) weight (kg)81085092099010501110 Electrical connections for the Systec HX-90 2D to HX-200 2D: 380 400 V, 50 / 60 Hz, 16 connections for the Systec HX-320 2D to HX-650 2D: 380 400 V, 50 / 60 Hz, 32 connections for the Systec HX-580 2D to HX-1580 2D: 380 400 V, 50 / 60 Hz, 63 voltage available upon see dimensions on separate see dimensions on separate see dimensions on separate drawing. 8 02/2017714685863535495635 Systec H-Series / H-Series with two chamber diameter: 740 mm and 1000 mm. 1000 mm diameter chamber provides the usable chamber dimension of a 6 x 6 square chamber H-Series, Systec H-Series 740 mmDiameter 1000 mm 9 02/2017 Systec H-Series / H-Series standard FeaturesIntegrated, separate steam generatorHousing, support frame and pressure vessel made of corrosion-resistant stainless steelTemperature and pressure range 140 C, 4 barTouch-Screen controlNumber of sterilization programsup to 100 Code-secured access rights for changing parameters and further safety-relevant interventionInternal memory for storing up to 500 sterilization cyclesTimer for starting programsAutofill.

8 Automatic demineralized water feed for steam generationFlexible PT-100 temperature sensorAdditional temperature sensor in condense exhaustTemperature holding function for liquids after program finishSpecial program for Durham tubesCalculation of F0 valueSpecial program for waste sterilization with pulsed heat-up for more efficient air exhaustWater-cooled steam exhaust, thermostatically controlledProgrammable automatic door-opening on completion of programRS-232 and RS-485 interfaces for external data transmission (network-compatible)Available optionsExtension of temperature and pressure ranges to 150 C / 5 bar (from chamber volume 65 liters to 650 liters)Options for process optimizationRapid cooling for efficient and safe cooling of liquidsVacuum system for validatable sterilization of solids and waste materials in disposal bagsSuperdry for drying solids (only in combination with optional vacuum system)Exhaust filtration (including condensate inactivation) for safe sterilization of hazardous biological substancesOptions for documentationIntegrated printer for batch documentationSystec ADS documentation software package for comprehensive documentationDocumentation SD: data storage on SD card for up to 10,000 sterilization cycles and transmission of data to a PCSystec ADS CFR documentation software package with conformity to FDA 21 CFR Part 11 AuditTrail: unalterable and traceable documentation acc.

9 To FDA 21 CFR Part 11 Systec Autoclaves are delivered ready for subsequent installation of all options. Further options and special programs as well as baskets and inserts, transport and loading systems on request. = Standard = OptionalHX Temperature- and pressure-dependent door locking in line with international standards and regulations Redundant process control; temperature and pressure are continuously monitored and controlled during the entire sterilization cycle Rapid heat-up via optimized heat transfer to the liquid media Flexible PT-100 temperature sensor for temperature measurement in a reference vessel: - Guarantees attainment of the desired sterilization temperature in the liquid media - Guarantees cooling of the liquid media to a temperature that is safe for removalStandard functions in all models 10 02/2017 Systec Design and according to norms and regulationsEquipped for the future!

10 Systec H-Series Autoclaves are the first to be designed for higher temperatures and pressures. The pressure vessel is designed for operations at 150 C and 5 bar. Optional temperature and pressure range extension accessories adapt all control and safety components to the higher temperature and pressure. This option can be for Systec H-Series Autoclaves 65 to 650 liter. HXDemineralized water inlet for steam generationCompressed air (standard in models from 210l)Cooling waterCommon outletRS-232 / RS-485 interfacesFlexible cord with CEE plug = Standard = OptionalDesign pure engineeringSystec Autoclaves are state-of-the-art, both in their mechanical and electrical components; ensuring a new quality of Laboratory sterilization processes. The enhanced components enable the lab to meet appropriate requirements for today and the qualityThe pressure vessel is made of corrosion-resistant stainless steel (V4A) AISI 316 Ti and is thus easy to clean.