TAB-ON TERMINAL . 250 TAB-ON type Mating tab T. 8. L. W E. Chamfering Listed E70188 Certified LR20812. Applicable wire Dimensions(mm). Model No. Standard Insulation Material Finish Mating Q ty/. T Material mm2 AWG # W L E approx. thickness tab reel (mm) thickness STO-21-250N . to 22 to 18 to STO-21T-250N Tin-plated 5,000. STO-61-250N . to 18 to 14 to STO-61T-250N Tin-plated Brass STO-81-250N . to 14 to 12 to 4,000. STO-81T-250N Tin-plated UL1015 #20 + UL1015 #20. *STO-62T-250N UL1015 #18 + UL1015 #20 Tin-plated 5,000. UL1015 #18 + UL1015 #18. RoHS compliance Note: TERMINAL denoted by * is used only for two wires. If using wires in other combinations than the ones shown above, contact JST. 250 TAB-ON piggyback type T. L. E. W. Listed E70188 Certified LR20812. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish W L E. T Material Mating reel mm2 AWG # approx. thickness tab (mm) thickness SFT-61T-250N to 18 to 14 to Brass Tin-plated 3,000. RoHS compliance 250 TAB-ON flag type Mating tab T.

2 TAB-ON TERMINAL 205 Tab-on type Q´ty/ reel Dimensions(mm) Mating tab thickness T W L E approx. MaterialFinish Applicable wire Model No. Standard mm2 AWG # Insulation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TAB-ON TERMINAL - jst-mfg.com

1 TAB-ON TERMINAL . 250 TAB-ON type Mating tab T. 8. L. W E. Chamfering Listed E70188 Certified LR20812. Applicable wire Dimensions(mm). Model No. Standard Insulation Material Finish Mating Q ty/. T Material mm2 AWG # W L E approx. thickness tab reel (mm) thickness STO-21-250N . to 22 to 18 to STO-21T-250N Tin-plated 5,000. STO-61-250N . to 18 to 14 to STO-61T-250N Tin-plated Brass STO-81-250N . to 14 to 12 to 4,000. STO-81T-250N Tin-plated UL1015 #20 + UL1015 #20. *STO-62T-250N UL1015 #18 + UL1015 #20 Tin-plated 5,000. UL1015 #18 + UL1015 #18. RoHS compliance Note: TERMINAL denoted by * is used only for two wires. If using wires in other combinations than the ones shown above, contact JST. 250 TAB-ON piggyback type T. L. E. W. Listed E70188 Certified LR20812. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish W L E. T Material Mating reel mm2 AWG # approx. thickness tab (mm) thickness SFT-61T-250N to 18 to 14 to Brass Tin-plated 3,000. RoHS compliance 250 TAB-ON flag type Mating tab T.

2 8. E L. W. Chamfering Listed E70188 Certified LR20812. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish W L E. T Material Mating reel mm2 AWG # approx. thickness tab (mm) thickness SFO-61-250A . to 18 to 14 to Brass 3,000. SFO-61T-250A Tin-plated RoHS compliance 1. TAB-ON TERMINAL . 205 TAB-ON type Mating tab T. Mating tab L. W E thickness Chamfering Listed E70188 Certified LR20812. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish W L E. T Material Mating reel mm2 AWG # approx. thickness tab (mm) thickness STO-21-205N . STO-21T-205N Tin-plated to 22 to 18 to Brass 7,500. STO-21-205N-5 . STO-21T-205N-5 Tin-plated RoHS compliance 187 TAB-ON flag type Mating tab T. L Mating tab E. W thickness Chamfering Listed E70188 Certified LR20812. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish W L E. T Material Mating reel mm2 AWG # approx. thickness tab (mm) thickness SFO-41-187N . SFO-41T-187N Tin-plated to 20 to 16 to Brass 5,000.

3 SFO-41-187N-8 . SFO-41T-187N-8 Tin-plated RoHS compliance 2. TAB-ON TERMINAL . 187 TAB-ON type Mating tab T. Mating tab L thickness W E. Chamfering Listed E70188 Recognized E70188 (AWG #24) Certified LR20812. Applicable wire Dimensions(mm). Insulation Mating Q'ty/. Model No. Standard Material Finish T Material mm2 AWG # W L E approx. thickness tab reel (mm) thickness STO-01-187N . STO-01T-187N Tin-plated to 24 to 20 to Brass 10,000. STO-01-187N-8 . STO-01T-187N-8 Tin-plated STO-41-187N . STO-41T-187N Tin-plated to 20 to 16 to Brass 10,000. STO-41-187N-8 . STO-41T-187N-8 Tin-plated UL1015 #20 + UL1015 #20. *STO-62T-187N UL1015 #18 + UL1015 #20 Brass Tin-plated 4,000. UL1015 #18 + UL1015 #18. UL1015 #18 + UL1015 #18. *STO-82T-187N UL1015 #18 + UL1015 #16 Brass Tin-plated 4,000. UL1015 #16 + UL1015 #16. RoHS compliance Note: TERMINAL denoted by * is used only for two wires. lf using wires in other combinations than the ones shown above, contact JST. 110 TAB-ON type Mating tab T L Chamfering E Mating tab W thickness Listed E70188 Recognized E70188 (AWG #24) Certified LR20812.

4 Applicable wire Dimensions(mm). Insulation Q ty /. Model No. Standard mm2 AWG # Material Finish W L E. T Material Mating reel approx. thickness tab (mm) thickness STO-01-110N . STO-01T-110N Tin-plated to 24 to 20 to STO-01-110N-8 . STO-01T-110N-8 Tin-plated Brass 10,000. STO-41-110N . STO-41T-110N Tin-plated to 20 to 16 to STO-41-110N-8 . STO-41T-110N-8 Tin-plated RoHS compliance 3. TAB-ON TERMINAL . Crimping machine, Applicator Crimping Applicator Crimping Applicator Contact Contact machine Crimp applicator Dies Crimp applicator with dies machine Crimp applicator Dies Crimp applicator with dies MK-L MK/STO-21-250 APLMK STO21-250N MK-L MK/STO-01-187N APLMK STO01-187N. STO-21(T)-250N STO-01(T)-187N(-8).. MK-L MK/STO-61-250N APLMK STO61-250N MK-L MK/STO-41-187N APLMK STO41-187N. STO-61(T)-250N STO-41(T)-187N(-8).. MK-L MK/STO-81-250N APLMK STO81-250N MK-L-187 MK/STO-62-187N APLMK STO62-187N. STO-81(T)-250N STO-62T-187N.. AP-K2N. MK-L MK/STO-62-250N APLMK STO61-250N MK-L-187 MK/STO-82-187N APLMK STO82-187N.

5 STO-62T-250N STO-82(T)-187N.. AP-K2N. MKS-L MK/SFT-61-250N A P L S F T 6 1 - 2 5 0 N MK-L MK/STO-01-110N APLMK STO01-110N. SFT-61T-250N STO-01(T)-110N(-8).. MKF-L-250 MK/SFO-61-250A A P L S F O 6 1 - 2 5 0 A MK-L MK/STO-41-110N APLMK STO41-110N. SFO-61(T)-250A STO-41(T)-110N(-8).. MK-L MK/STO-21-205N A P L S T O 2 1 - 2 0 5 N. STO-21(T)-205N(-5).. MKF-L-187 MK/SFO-41-187N A P L S F O 4 1 - 1 8 7 N. SFO-41(T)-187N(-8).. * Refer to "General Instruction and Notice when using Terminals and Connectors" at the end of this catalog. * Contact JST for details. * Compliant with RoHS. 4. TAB-ON -TAB TERMINAL . 250 TAB-ON tab type E L. W. Listed E70188. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish Material Tab mm2 AWG # W L E reel (mm) thickness thickness SOM-51-250 . to 20 to 14 to Brass 5,000. SOM-51T-250 Tin-plated RoHS compliance 187 TAB-ON tab type L. W E. Listed E70188. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish Material Tab mm2 AWG # W L E reel (mm) thickness thickness SOM-21-187.

6 To 22 to 18 to Brass 10,000. SOM-21T-187 Tin-plated RoHS compliance Crimping machine, Applicator Crimping Applicator Crimping Applicator Contact Contact machine Crimp applicator Dies Crimp applicator with dies machine Crimp applicator Dies Crimp applicator with dies MK-L MK/SOM-51-250 APLMK SOM51-250 MK-L MK/SOM-21-187 APLMK SOM21-187. SOM-51(T)-250 AP-K2N SOM-21(T)-187 AP-K2N.. * Refer to "General Instruction and Notice when using Terminals and Connectors" at the end of this catalog. * Contact JST for details. * Compliant with RoHS. 5. TAB-IN/TAB-IN-TAB TERMINAL . 250 Tab-in type T. L. E. W. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish T Material Mating mm2 AWG # W L E approx. thickness tab reel (mm). STI-51-250N SIM-51. to 20 to 14 to Brass 5,000. STI-51T-250N Tin-plated (T)-250N. RoHS compliance Note: 1. Combine a plated tab-in TERMINAL with a plated tab and a non-plated tab-in TERMINAL with a non-plated tab. 2. This TERMINAL must be built into the model 250 tab-in housing which has numerous circuits, and it cannot be used independently.

7 Model 250 TAB-ON terminals, however, can be used independently. 3. The above case does not apply when we confirm the condition of application and judge that there is no problem. 110 Tab-in type T. L. W E. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish T Material Mating mm2 AWG # W L E approx. thickness tab reel (mm). STI-01-110N SIM-01. to 22 to 20 to STI-01T-110N Tin-plated (T)-110A. Brass 10,000. STI-41-110N SIM-41. to 20 to 16 to (T)-110B. STI-41T-110N Tin-plated RoHS compliance Note: 1. Combine a plated tab-in TERMINAL with a plated tab and a non-plated tab-in TERMINAL with a non-plated tab. 2. This TERMINAL must be built into the model 110 tab-in housing which has numerous circuits, and it cannot be used independently. Model 110 TAB-ON terminals, however, can be used independently. Crimping machine, Applicator Applicator Applicator Crimping Crimping Contact Crimp applicator Contact Crimp applicator machine Crimp applicator Dies machine Crimp applicator Dies with dies with dies MK-L MK/STI-51-250N APLMK STI51-250N MK-L MK/STI-41-110N APLMK STI41-110N.

8 STI-51(T)-250N STI-41(T)-110N AP-K2N.. AP-K2N. MK-L MK/STI-01-110N APLMK STI01-110N. STI-01(T)-110N.. 6. TAB-IN/TAB-IN-TAB TERMINAL . 250 Tab-in tab type L. E. W. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish Material Tab mm2 AWG # W L E reel (mm) thickness thickness SIM-21-250 . to 22 to 18 to 5,000. SIM-21T-250 Tin-plated SIM-51-250N Brass to 20 to 14 to 4,000. SIM-51T-250N Tin-plated SIM-81PT-250N to 16 to 12 to 3,000. RoHS compliance Note: SIM-21 differs from SIM-51 in TERMINAL size. 110 Tab-in tab type E L. W. Listed E70188. Applicable wire Dimensions(mm). Insulation Q ty/. Model No. Standard Material Finish Material Tab mm2 AWG # W L E reel (mm) thickness thickness SIM-01-110A . to 22 to 20 to SIM-01T-110A Tin-plated Brass 7,500. SIM-41-110B . to 20 to 16 to SIM-41T-110B Tin-plated RoHS compliance Crimping machine, Applicator Crimping Applicator Crimping Applicator Contact Contact machine Crimp applicator Dies Crimp applicator with dies machine Crimp applicator Dies Crimp applicator with dies MK-L MK/SIM-21-250 APLMK SIM21-250 MK-L MK/SIM-01-110A APLMK SIM01-110A.

9 SIM-21(T)-250 SIM-01(T)-110A.. AP-K2N. MK-L MK/SIM-51-250N APLMK SIM51-250N MK-L MK/SIM-41-110B APLMK SIM41-110B. SIM-51(T)-250N AP-K2N SIM-41(T)-2110B.. MK-L MK/SIM-81-250N APLMK SIM81-250N. SIM-81PT-250N.. * Refer to "General Instruction and Notice when using Terminals and Connectors" at the end of this catalog. * Contact JST for details. * Compliant with RoHS. 7.