Example: air traffic controller

tapcon data sheet - construction fixings

technical data sheet www: constructionfi information detailed in our data sheets is based on technical approvals, formulas and site and laboratory testing under optimum conditions and include a stated safety factor. As we have no direct or indirect control over where or how our products are applied or installed, we do not accept any liability either directly or indirectly arising from the use of our products, whether or not in accordance with any advice, specifi cation or reccomendation given by us and we reccomend site testing of all products for Head and Countersunk TapconDrill, Drive, DoneThe original masonry fastening system that cuts it s own thread into concrete,brick and hollow Advantages Fast installation, Drill, Drive, Done Available in M5 and M6 and in lengths from 32 - 125mm, to cover a wide number of applications Every box includes a free close tolerance masonry bit Replaces small diameter expansion anchors.

technical data sheet 1 www: constructionfi xings.com All information detailed in our data sheets is based on technical approvals, formulas and site and laboratory testing under optimum conditions and include a stated safety factor.

Tags:

  Sheet, Data, Technical, Technical data sheet, Tapcon data sheet, Tapcon

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of tapcon data sheet - construction fixings

1 technical data sheet www: constructionfi information detailed in our data sheets is based on technical approvals, formulas and site and laboratory testing under optimum conditions and include a stated safety factor. As we have no direct or indirect control over where or how our products are applied or installed, we do not accept any liability either directly or indirectly arising from the use of our products, whether or not in accordance with any advice, specifi cation or reccomendation given by us and we reccomend site testing of all products for Head and Countersunk TapconDrill, Drive, DoneThe original masonry fastening system that cuts it s own thread into concrete,brick and hollow Advantages Fast installation, Drill, Drive, Done Available in M5 and M6 and in lengths from 32 - 125mm, to cover a wide number of applications Every box includes a free close tolerance masonry bit Replaces small diameter expansion anchors.

2 Plugs and screws in light to medium duty applications No need to pre-spot holes, no inserts are required Removable - Adjustable Can be installed close to edges Slotted Hex and Phillips flat head styles give flexibility in applications Excellent corrosion protection Available in 410 Stainless Steel (Price on application) Fire resistantSpecificationDiameter5mm and 6mmThread formReversed Hi-Lo Point typeNailFinishBlue ClimasealKesternich Results (DIN 5008, ) = 30 Cycles - 10% or less red rustSalt Spray Results (ASTM B117) = 750 Hours - 10% or less red rustMechanical and Electrical ApplicationsFixing Electrical AccessoriesServices Saddles Ductwork Conduit clips Cable trays, channel Back boxes Suspended ceilings P Clips Cable clips Cable cleatsCorrosion - Salt spray results (ASTM B117)Head StylesPhillips Flat Head 5mm Diameter: P2 Phillips Flat Head 6mm Diameter: P3 Phillips Flat Head Slotted Hex Washer Head 5mm Diameter: Slotted Hex Washered Head 6mm Diameter: 8mm Slotted Hex Washered HeadApprovalsSBCCi Approved 9759 Metro-Dade Approved 02 - 0311 - 03 ICBO Approved 3370 Substrates Concrete Masonry Blockwork Pre-cast hollow concrete beams Wood1.

3 With Condrive Sleeve off and drill bit exposed,drill pilot hole deeper than recommended anchor embedment. Snap correct anchor socket / drive bitonto end of Condrive Sleeve. Slide Condrive Sleeve over drill Insert head of tapcon anchor into Hex or Phillips Put point of anchor into pre-drilled hole and drive until anchor is fully Ensure that the drilling tool is not set to hammer action during to Concrete Metalwork Formwork Railings, hand rails Battens Gates, brackets and signs Base plates Fire protection and exterior Plywood backer boardsinsulation systems to masonrySteel and Concrete Applicationstechnical data sheet www: constructionfi information detailed in our data sheets is based on technical approvals, formulas and site and laboratory testing under optimum conditions and include a stated safety factor.

4 As we have no direct or indirect control over where or how our products are applied or installed, we do not accept any liability either directly or indirectly arising from the use of our products, whether or not in accordance with any advice, specifi cation or reccomendation given by us and we reccomend site testing of all products for Hole EmbedMed Density Med Density20kN Concrete20kN Concrete25kN Concrete25kN Concrete 35kN Concrete 35kN Concrete DepthBlock Tensile Block ShearTensileShearTensileShearTensileShea r5mm 4mm 25mm 4mm 32mm 4mm 38mm 4mm 44mm 5mm 25mm 5mm 32mm 5mm 38mm 5mm 44mm data - tapcon Recommended* Shear and Tensile Values in ConcreteAnchor DiameterHole DiameterEmbedment DepthTensile LoadsShear data - tapcon Recommended* Shear and Tensile Values in Hollow BlockAnchor DiameterHole DiameterEmbedment DepthTensile data - tapcon Recommended*

5 Values in Richard Lees Spiroll Concrete Floor and Roof UnitsAnchor DiameterHole DiameterEmbedment DepthTensile data - tapcon Recommended* Values in Trent Jetfloor Concrete Flooring SystemsAnchor DiameterHole DiameterEmbedment DepthTensile is a registered trademark of Bison Floors is a registered trademark of Trent Jet Floor and Tembo is a registered trademark of Richard Lees Ltd.*A safety factor of 3 has been taken into consideration for a single installation (anchor) to calculate the safe working data - tapcon Recommended* Values in Bison Pre-cast Floor Unitstechnical data sheet www: constructionfi information detailed in our data sheets is based on technical approvals, formulas and site and laboratory testing under optimum conditions and include a stated safety factor.

6 As we have no direct or indirect control over where or how our products are applied or installed, we do not accept any liability either directly or indirectly arising from the use of our products, whether or not in accordance with any advice, specifi cation or reccomendation given by us and we reccomend site testing of all products for data - tapcon Strength and ReliabilityTapcon masonry anchors are manufactured from special high quality cold forming steel, heat treated to give hard cuttingsurfaces for efficient thread cutting action in a wide variety of masonry materials. The standard finish on tapcon anchors iselectroplated and passivated zinc with colour identifying blue coating. Rigid quality control in all phases of production ensures consistent and reliable performance.

7 tapcon anchors have beenlaboratory tested on an Avery Denison testing machine in concrete product manufacturers standard materials. Appropriatecuring times were allowed for the masonry test blocks to ensure reliable Newton ConcreteTypical Dense Concrete BlockCommon BrickTypical Hollow Concrete Beam25303540452468101214 PULLOUT (kN)DEPTH OF EMBEDMENT (mm) 6mm Anchor 5mm RecommendedEmbedment25303540451234567 PULLOUT (kN)DEPTH OF EMBEDMENT (mm) 6mm Anchor 5mm (kN)DEPTH OF EMBEDMENT (mm) 6mm Anchor 5mm (kN)DEPTH OF EMBEDMENT (mm) 6mm Anchor 5mm Pot MinimumThickness 27mmSolid web All loads detailed above are ultimate failure loads and should have a safety factor of 3 applied.


Related search queries