lutron Electronics Co., Suter RoadCoopersburg, PA 18036-1299, and printed in the 4/07 P/N 033-103 Rev. AEnglishCanopy ModuleCM-L300FQ1: 120 V~ 60 Hz 300 W light / 1 A fan ( A total)Wall ControlMIR-LFQ35:120 V~ 60 Hz A (one CM-L300FQ1) Infrared Wireless TransmitterMIR-ITFS-LF: 3 WImportant NotesPlease read before :To avoid overheating and possible damage to other equipment, do not use tocontrol receptacles, fluorescent or neon lighting fixtures, transformer-supplied appliances,solid state fan motors,or exhaust fans. For exhaust fans use lutron fully variable fan in accordance with all national and local electrical no grounding means exist within the wallbox then the NEC 2005, Article a wall control without a grounding connection to be installed as a replacement, aslong as a plastic, noncombustible wallplate is used.

Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299, U.S.A. Made and printed in the U.S.A. 4/07 P/N 033-103 Rev. A English Canopy Module

Tags:

  Technical, Electronic, Lutron electronics, Lutron

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Technical Assistance Infrared Wireless Transmitter …

1 lutron Electronics Co., Suter RoadCoopersburg, PA 18036-1299, and printed in the 4/07 P/N 033-103 Rev. AEnglishCanopy ModuleCM-L300FQ1: 120 V~ 60 Hz 300 W light / 1 A fan ( A total)Wall ControlMIR-LFQ35:120 V~ 60 Hz A (one CM-L300FQ1) Infrared Wireless TransmitterMIR-ITFS-LF: 3 WImportant NotesPlease read before :To avoid overheating and possible damage to other equipment, do not use tocontrol receptacles, fluorescent or neon lighting fixtures, transformer-supplied appliances,solid state fan motors,or exhaust fans. For exhaust fans use lutron fully variable fan in accordance with all national and local electrical no grounding means exist within the wallbox then the NEC 2005, Article a wall control without a grounding connection to be installed as a replacement, aslong as a plastic, noncombustible wallplate is used.

2 For this type of installation, cap orremove the green ground wire on the wall control and use an appropriate wallplate such asLutron s Claro series Maestro IR dual fan/light control system consists of a Wall Control and a CanopyModule. Both must be installed correctly before attempting to control the fan/light fixture. Donot attempt to mix lutron controls with those from other manufacturers, or mix Lutroncontrols not labeled for use system is not compatible with fans having a control system built into the not paint Wall Control or Canopy not use where total lamp wattage is less than 40 W or greater than 300 between 32 F (0 C) and 104 F (40 C) room temperature.

3 For indoor use Control may feel warm to the touch during normal wallbox depth is in (64 mm) Clean Wall Control with a soft damp cloth not use any chemical system cannot be used to change the direction of the fan. To change the fan direction,stop the fan, and then change the position of the switch located on the body of the maximize light bulb life, use bulbs recommended for fan or rough service not use pull chains to operate fan/light after installing this Module must be installed within a fan canopy device complies with Part 15 of the FCC Rules. Operation is subject to the following twoconditions: (1) this device may not cause harmful interference, and (2) this device mustaccept any interference received, including interference that may cause undesired Quiet Fan Speed and Incandescent/Halogen Dimmer Single-Location SystemFan/LightWarning: For use with one ceiling paddle fan and light only.

4 Do not use with anexhaust fan or more than one ceiling fan onlyNo exhaust fansNOTE: This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonableprotection against harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance withthe instructions, may cause harmful interference to radio communications. However, there is noguarantee that interference will not occur in a particular installation. If this equipment doescause harmful interference to radio or television reception, which can be determined by turningthe equipment off and on, the user is encouraged to try to correct the interference by one ormore of the following measures:- Reorient or relocate the receiving Increase the separation between the equipment and Connect the equipment into an outlet on a circuit different from that to which the receiver Consult the dealer or an experienced radio/TV technician for 033-103 Limited Warranty(Valid only in , Canada, Puerto Rico, and the Caribbean.)

5 lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after warranty service, return unit to place of purchase or mail to lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITYIS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL ORREINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING ORINSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. lutron S LIABILITY ONANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION,DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE warranty gives you specific legal rights, and you may have other rights which vary from state to state.

6 Some states do notallow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last,so the above limitations may not apply to product may be covered under the following patents: 4,835,343, 4,992,709, 5,017,837, 5,248,919, 5,399,940,5,637,930, 5,909,087, 6,169,377, 6,380,696, 7,142,932, 7,190,125; D525,948; and corresponding foreign patents. andforeign patents pending. lutron , Claro, Maestro, and Maestro IR are registered trademarks and FASS is a trademark of LutronElectronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.

7 2007 lutron Electronics Co., Level Tap Button Tap once when lights are off -Lights brighten smoothly to presetintensity. Tap once when lights are on -Lights dim smoothly to off. Tap twice quickly -Lights brightenrapidly to full intensity. Press and hold when lights are on-Activates delayed fade to off the tap button is held, the LEDswill begin to flash. The first flashingLED represents a 10 second fade toOFF. Each additional flashing LEDrepresents an additional 10 secondsof delay before lights fade to OFF (upto 60 seconds of delay).Fan Speed Tap Button Tap once when fan is off -Fanspeed increases to preset level. Tap once when fan is on -Fanspeed slows to off.

8 Tap twice quickly -Fan speedincreases to full Level LEDs Indicate approximate light levelLEDs may not change with eachpressPress to increase light levelPress to decrease light levelFan speed LEDs Indicate exact fan speedLEDs will change with each pressPress to increase fan speedPress to decrease fan speed(LEDs not available on Accessory Controls)FASSTM- FrontAccessibleService SwitchIMPORTANT NOTICE:To replace bulb, remove power by pulling the FASS switch out on the any procedure other than routine bulbreplacement, power must be disconnected at themain electrical InstallationsWhen installing more than one control in the same wallbox, it may be necessary to remove allinner side sections prior to wiring (see below).

9 Using pliers, bend side sections up and down untilthey break off. Repeat for each side section to be : Product does not requirederating when side sections are SideSectionsTechnical AssistanceIf you have questions concerning the installation or operation of this product, call theLutron Technical Support Center. Please provide exact model number when and Canada (24 hrs/7days):1-800-523-9466 Other countries 8am 8pm ET:+1-610-282-3800 Fax +1-610-282-6311 sections areremoved from eachcontrolSide sections areremoved from bothsides of middle controlDo not Wiring DiagramTroubleshootingSymptomLight or fan does not turn ON or no LEDsturn LEDs on Wall Control cycle rapidlyand bottom LED is LEDs on Wall Control cycle rapidlyand second lowest LED is vibrates or dims in large steps and fan is noisy ordoes not spin at correct button controls fan and speeds too Control LEDs respond as expected butfan and/or light does not respond or fan does not respond to infraredwireless Cause Front Accessible Service Switch (FASS)

10 Oncontrol is pulled out to the OFF position. Manual switch on fan is off (ex: pull chain). Light bulb(s) burned out. Breaker is OFF or tripped (or fuse blown). Fan direction switch is between forward andreverse. Wiring error, call lutron Technical SupportCenterat 1-800-523-9466. Unit is not activated properly. Activate systemas described in Step 14. Wiring error, call lutron Technical SupportCenterat 1-800-523-9466. Communication error. Check wiring; if errorcontinues, call lutron Technical SupportCenterat 1-800-523-9466. Fan blades not properly balanced. See fanmanufacturer's instructions. Fan and light control wires on Canopy Moduleare reversed.