Example: barber

Technical Data BMS PRO 2 - cooperindustries.com

Technical Data Effective March 2018. BMS PRO 2. Project Name: Prepared By: BMS Pro 2. Project Number: Date: Catalog Number: Type: Overview Eaton BMS Pro 2 is a feature-rich, high performance protocol translator and wireless gateway which allows data exchange between Eaton's Greengate, iLumin and Fifth Light lighting control systems and the Building Automation Systems. The gateway converts Eaton's Greengate, iLumin and Fifth Light lighting control systems' protocols to BACnet/IP, BACnet MS/TP, Modbus TCP/IP, Modbus RTU and LON. This BTL Certified devices also hosts a BACnet Explorer client and a BACnet Broadcast Management Device (BBMD). The integrated BACnet Explorer eliminates the need for third party BACnet software packages and connectors to automatically discover BACnet devices and browse the BACnet networks for configuration and diagnostics. The BACnet BBMD allows data exchanges between BACnet subnets hence eliminating the need for an external BBMD.

ATO www.eaton.com/lightingsystems 3 Technical Data Effective March 2017 BMS PRO 2 Compliances, specifications and availability are subject to change without notice ...

Tags:

  Cooperindustries

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Technical Data BMS PRO 2 - cooperindustries.com

1 Technical Data Effective March 2018. BMS PRO 2. Project Name: Prepared By: BMS Pro 2. Project Number: Date: Catalog Number: Type: Overview Eaton BMS Pro 2 is a feature-rich, high performance protocol translator and wireless gateway which allows data exchange between Eaton's Greengate, iLumin and Fifth Light lighting control systems and the Building Automation Systems. The gateway converts Eaton's Greengate, iLumin and Fifth Light lighting control systems' protocols to BACnet/IP, BACnet MS/TP, Modbus TCP/IP, Modbus RTU and LON. This BTL Certified devices also hosts a BACnet Explorer client and a BACnet Broadcast Management Device (BBMD). The integrated BACnet Explorer eliminates the need for third party BACnet software packages and connectors to automatically discover BACnet devices and browse the BACnet networks for configuration and diagnostics. The BACnet BBMD allows data exchanges between BACnet subnets hence eliminating the need for an external BBMD.

2 Device. The BMS Pro 2 uses a 12-24V DC power input. As such it can be powered by the 24V DC power supplies available inside many Eaton's Lighting Control Panels or via a separate power supply (to be provided by others). A DIN rail mounting bracket is included with the gateway for easy mounting. 1. Only a subnet of Eaton's Lighting Control Panels include a 24 VDC power supply. Features Multi-protocol and lighting control systems support A single device that enables the integration of Eaton's Greengate, iLumin and Fifth Light system with third party system via BACnet/. IP, BACnet MS/TP, Modbus TCP/IP and Modbus RTU. Web-based Programming Interface The gateway's web-based user interface allows system integrators to easily program the gateway based on their needs. The installer selects the desired Eaton lighting control system and configure the gateway accordingly. Integrated BACnet Explorer The integrated BACnet explorer allows users to automatically discover the BACnet objects and associated properties exposed by the Eaton's lighting control system.

3 The user can browse, monitor and control the discovered devices and objects. Integrated BACnet Broadcast Management Device (BBMD). The integrated BBMD eliminates the need for an external BACnet Router to allow data exchange between two BACnet devices operating on different subnets. The BBMD will send any received broadcast messages as directed message through the IP router to its partner BBMD device. Diagnostics LEDs The gateway's LEDs allows user to easily detect failure or communication issues at the gateway. Technical Data BMS PRO 2. Effective March 2018. System Performance Property Values Supported Greengate System Room Controller (115 points per panel). ControlKeeper 2 (161 points per panel). ControlKeeper 4 (161 points per panel). ControlKeeper 4A (181 points per panel). ControlKeeper T (213 points per panel). ContolKeeper M/MB (225 points per panel). Control of Greengate System Manually turn relays & dimmers On/Off Check status of relays and dimmers Total Number of objects supported for Greengate 10,000.

4 Supported iLumin System SCUN. SCUN-FT. SCRP. SCRPB. Note : Based on imported Virtual Area File Control of iLumin System Manually trigger Area On/Off Manually trigger Scenes per area Total Number of objects supported for iLumin 10,000. Supported Fifth Light System All LCP Panels Control of Fifth Light System Refer to the PICS. Total Number of objects support for Fifth Light 10,000. Specifications Supported Protocols BACnet/IP, BACnet MS/TP, Modbus TCP/IP, Modbus RTU. Communication Serial (Galvanic Isolation): RS-485/RS-232. Baud: 9600, 19200, 34800, 57600, 76800. Ethernet: 10/100 Base/T. Power 12-24 VDC. 240 mA @ 12V. Environment Operating temperature: -20 C to 70 C (-20 F to 158 F). Relative humidity: 10-95% RH non-condensing Dimensions Dimensions: x x in. ( x x cm). Weight: lbs ( kg). Manufacturer FieldServer Technologies Approvals BTL Listing (under FieldServer Technologies, ProtoAir, FPA-W34 model). CE and FCC Class B & C Part 15. TUV Approved to UL 60950 pending IC Canada RoHS Compliant PTCRB and CTIA.

5 Other Web-based configuration Toolbox diagnostic utility Table, Wall mount DIN rail mount included Warranty 5 years 2 EATON Compliances, specifications and availability are subject to change without notice. BMS PRO 2 Technical Data Effective March 2017. System Architecture Greengate sample system topology Building LAN. (provided by others). BAS/BMS. Communicating BACnet/IP. or LON. EIM. Adjustable Skylight s White Switchpack 6. Purple - Load 3 Ou t Red - Load 2 Ou t Adjustable Skylights Receptacl e Red BMS/Out QuickConnect Cable s 5. Black Sensors Green Sensors CAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation . Slider 120V Power Station 4. Integration Controls Wallstations Yellow - Load 1 Out - BMS Pro 2. Blue - Load In A/V. Mode +. - Integration Controls 3. ControlKeeper Demand Respons e +. Receptacle Required Alert - Mode +. Time Cloc k - +. 2. White/Orange - 277V N. TouchScreen White/Black - 120V N.

6 1. Black - Line In Energy Options DI P Switch Demand Response Occupanc y Not Used High End Options Energy 1 2 3 4. Default 10% Occ 20% Vac (default). Reset 30%. 40%. Low End Status The Ethernet Interface Module (EIM). Adjustment 0-10V Gain 0-10V Dimming Outputs Blue - EM Loads Ou t + - + - + - Blue - EM Line In Dimmer 3 Dimmer 2 Dimmer 1. may be connected to any lighting Dimmer 3 Dimmer 2 Dimmer 1. + - + - + - 0-10V Dimming control panel in the system with an RS-232 port with the cable provided 24 VDC Power (PART #: 52-018703-00). (by others). Adjustable Skylights Adjustable Skylights White Switchpack 6 White Switchpack 6. Purple - Load 3 Ou t Purple - Load 3 Ou t Adjustable Skylight s Adjustable Skylight s Red - Load 2 Out Red - Load 2 Out Receptacl e Receptacl e Red Red BMS/Out BMS/Out QuickConnect Cables QuickConnect Cables 5 5. Black Sensors Black Sensors Green Sensors Green Sensors CAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation.

7 CAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation. Slider Slider Station Station 4 4. Integration Controls Integration Controls Wallstations Wallstations Yellow - Load 1 Out Yellow - Load 1 Out - - Blue - Load In Blue - Load In A/V A/V. Mode + Mode +. - - Integration Controls Integration Controls 3 3. Demand Demand Response + Response +. Alert - Alert - Mode + Mode +. Time Clock - +. Time Cloc k - +. 2 2. White/Orange - 277V N. White/Orange - 277V N. White/Black - 120V N. White/Black - 120V N. 1 1. Black - Line In Black - Line In Energy Options DI P Switch Energy Options DI P Switch Demand Response Occupanc y Not Used Demand Response Occupanc y Not Used Options High End Options High End Energy Energy 1 2 3 4 1 2 3 4. Default 10% Occ Default 10% Occ 20% Vac (default) 20% Vac (default). Rese t Rese t 30% 30%. 40% 40%. Low End Low End Status Status Adjustment Adjustment 0-10V Gain 0-10V Gain 0-10V Dimming Outputs 0-10V Dimming Outputs Blue - EM Loads Ou t Blue - EM Loads Ou t + - + - + - + - + - + - Blue - EM Line In Blue - EM Line In Dimmer 3 Dimmer 2 Dimmer 1 Dimmer 3 Dimmer 2 Dimmer 1.

8 Dimmer 3 Dimmer 2 Dimmer 1 Dimmer 3 Dimmer 2 Dimmer 1. + - + - + - + - + - + - 0-10V Dimming 0-10V Dimming iLumin sample system topology Compliances, specifications and availability are subject to change without notice. EATON 3. Technical Data BMS PRO 2. Effective March 2018. Fifth Light sample system topology DALI COMMUNICATION BUS. Maximum of up to 64 devices on each DALI Bus. All devices must be within Scene 1. Scene 2. 900 feet of the Lighting Control Scene 3. Scene 4 Panel (LCP). 16/2 AWG recommended wire. BUILDING. AUTOMATION DALI FIELD DALI DIMMABLE DALI MULTI DALI DAC DALI DIMMING DALI. SYSTEM RELAY BALLAST SENSOR 0-10 VDC MODULE WALLSTATION. 11:46 06/26/09 1000. FIFTH LIGHT TECHNOLOGY. DALI RELAY PANEL. 1 10%. 2 10%. 20%. 3 30%. 4 40%. Units Are: LIGHTS GROUPS SCENES SUPPORT. BMS PRO 2. LIGHTING. CONTROL PANEL VOIP PHONE TOUCH MOBILE. SCREEN APP. ETHERNET. NETWORK SWITCH. CENTRAL MANAGER. Ordering Important Notes: 1. For a Greengate system, an EIM (Ethernet Interface Module) is required.

9 The EIM is a serial to Ethernet converter. Please refer to the wiring diagram section above and required accessories section below. 2. For an iLumin system, an EG2 (Ethernet Gateway) is required. The EG2 is an iCAN to Ethernet converter. Please refer to the wiring diagram section above and required accessories section below. 3. For a Fifth Light system, no physical layer converter is required. 4. The BMSPro 2 can only connect to a single system. Catalog # Description FPA-W34-1130 BMSPro 2. Required Accessories Catalog # Description EIM Ethernet Interface Module (Required for all Greengate Installations). EG2-NA Ethernet Gateway (Required for all iLumin installations). Eaton 1121 Highway 74 South Peachtree City, GA 30269. For service or Technical assistance: 1-800-553-3879. 2018 Eaton All Rights Reserved Printed in USA. Publication No. TD620094EN Specifications and dimensions subject to March 2018 change without notice.