Example: stock market

Technical Data Sheet

^(ValidationDate)3453451,2alkydTechnical Data SheetAluminium Paint descriptionThis is a one component styrene modified oxidatively drying alkyd coating . It is heat resistant up to 250 C. Can be used as an exterior aluminium finish usually within an alkyd system. Can be used as primer, mid coat or finish coat in atmospheric environments. Suitable for properly prepared carbon steel and aluminium useExhaust pipes, process piping and engine dataPropertyTest/StandardDescriptionSoli ds by volumeGloss level (GU 60 )ISO 2813 VOC-US/Hong KongUS EPA method 24 (tested)(CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)VOC-EUIED (2010/75/EU) (theoretical)The provided data is typical for factory produced products, subject to slight variation depending on pointISO 3679 Method 136 Caluminium sheen435 g/l416 description: According to Jotun Performance Coatings' 3233 VOC-ChinaGB/T 23985-2009 (tested)419 g/lVOC-KoreaKorea Clean Air Conservation Act (tested)(Max.)

Depending on the actual exposure of the coating system, various primers and topcoats can be used in ... thereafter the paint quality is subject to re-inspection. This product cannot be stored at temperatures above 40°C. Recommended storage temperature is 5 – 30°C. ... and specific application practices. If there is any inconsistency between ...

Tags:

  Practices, Inspection, Coating

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Technical Data Sheet

1 ^(ValidationDate)3453451,2alkydTechnical Data SheetAluminium Paint descriptionThis is a one component styrene modified oxidatively drying alkyd coating . It is heat resistant up to 250 C. Can be used as an exterior aluminium finish usually within an alkyd system. Can be used as primer, mid coat or finish coat in atmospheric environments. Suitable for properly prepared carbon steel and aluminium useExhaust pipes, process piping and engine dataPropertyTest/StandardDescriptionSoli ds by volumeGloss level (GU 60 )ISO 2813 VOC-US/Hong KongUS EPA method 24 (tested)(CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)VOC-EUIED (2010/75/EU) (theoretical)The provided data is typical for factory produced products, subject to slight variation depending on pointISO 3679 Method 136 Caluminium sheen435 g/l416 description: According to Jotun Performance Coatings' 3233 VOC-ChinaGB/T 23985-2009 (tested)419 g/lVOC-KoreaKorea Clean Air Conservation Act (tested)(Max.)

2 Thinning ratio included)410 g/l 2 %Film thickness per coatDry film thicknessWet film thicknessTheoretical spreading rateTypical recommended specification m mm /l---Date of issue:4 December 2020 Page: 1/4 This Technical Data Sheet supersedes those previously Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at Data SheetAluminium Paint preparation summary tableSubstrateMinimumRecommendedSa 2 (ISO 8501-1)Carbon steelSa 2 (ISO 8501-1)AluminiumThe surface shall be hand or machine abraded with non-metallic abrasives or bonded fibre machine or hand abrasive pads to impart a scratch pattern to the corresponding to description of Sa 1 (ISO 8501-1)Shop primed steelClean, dry and undamaged shop primer (ISO 12944-4 )Sa 2 (ISO 8501-1)

3 Coated surfacesClean, dry and undamaged compatible coatingClean, dry and undamaged compatible coatingSurface preparationApplication methodsThe product can be applied bySpray:Use air spray or airless :Recommended for stripe coating and small areas. Care must be taken to achieve the specified dry film :May be used for small areas. Not recommended for first primer coat. Care must be taken to achieve the specified dry film preparationTo secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any packProduct mixingThinner/Cleaning solventThinner:Jotun Thinner No. 2 Nozzle tip (inch/1000):Pressure at nozzle (minimum):Guiding data for airless spray15-19150 bar/2100 psiDate of issue:4 December 2020 Page: 2/4 This Technical Data Sheet supersedes those previously Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the Application Guide (AG) for this product.

4 For your nearest local Jotun office, please visit our website at Data SheetAluminium Paint and Curing timeSurface (touch) dryWalk-on-dry30 min30 min30 min15 min18 h14 h10 h8 hSubstrate temperature5 C10 C23 C40 CDry to over coat, minimum24 h12 h8 h6 hWalk-on-dry: Minimum time before the coating can tolerate normal foot traffic without permanent marks,imprints or other physical and curing times are determined under controlled temperatures and relative humidity below 85 %, and at average of the DFT range for the to over coat, minimum: The recommended shortest time before the next coat can be (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal maximum overcoating intervals, refer to the Application Guide (AG) for this , atmosphericHeat resistance C250 ContinuousPeak-Product compatibilityPrevious coat:inorganic zinc silicate shop primerPackaging (typical)The volume stated is for factory made colours.

5 Note that local variants in pack size and filled volumes can vary due to local of containers(litres)Aluminium Paint Volume(litres)Depending on the actual exposure of the coating system, various primers and topcoats can be used in combination with this product. Some examples are shown below. Contact Jotun for specific system of issue:4 December 2020 Page: 3/4 This Technical Data Sheet supersedes those previously Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at Data SheetAluminium Paint product must be stored in accordance with national regulations.

6 Keep the containers in a dry, cool, well ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle with life at 23 C24 Aluminium Paint (s)In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf life, thereafter the paint quality is subject to product cannot be stored at temperatures above 40 C. Recommended storage temperature is 5 30 product is for professional use only. The applicators and operators shall be trained, experienced and have the capability and equipment to mix/stir and apply the coatings correctly and according to Jotun's Technical documentation.

7 Applicators and operators shall use appropriate personal protection equipment when using this product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit the site conditions shall be forwarded to the responsible Jotun representative for approval before commencing the and safetyPlease observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought variation When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations from batch to batch.

8 Such products may fade and chalk when exposed to sunlight and and gloss retention on topcoats/finish coats may vary depending on type of colour, exposure environment such as temperature, UV intensity etc., and application quality. Contact your local Jotun office for further information in this document is given to the best of Jotun's knowledge, based on laboratory testing and practical experience. Jotun's products are considered as semi-finished goods and as such, products are often used under conditions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product itself. Minor product variations may be implemented in order to comply with local requirements.

9 Jotun reserves the right to change the given data without further should always consult Jotun for specific guidance on the general suitability of this product for their needs and specific application there is any inconsistency between different language issues of this document, the English (United Kingdom)version will of issue:4 December 2020 Page: 4/4 This Technical Data Sheet supersedes those previously Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at


Related search queries