Example: barber

Technical Data Sheet for RL with Innovator Doors - …

Merchandisers KEFCGBIAJDHMLRL with INNOVATORD oorsTechnical data SheetP/N 0425644_PNSF CertifiedNovember 2009We reserve the right to changeor revise specifications andproduct design in connectionwith any feature of our products. Such changes do not entitle the buyer to corresponding changes,improvements, additions orreplacements for equipmentpreviously sold or :Terminal block NOT for case-to-case wire connection!Item Part #DescriptionWiring Item #FANASSEMBLIES, StandardFan Assembly (1)0047000 Fan Motor, Evaporator ( )0461805 Fan Blade ( )12W Optional Energy EfficientFan Assembly (1)0477655 Fan Motor, Evaporator( )0461805 Fan Blade ( )B. 0474033 Standard Non-adjustable (2)Defrost Thermostat ( ) Adjustable Refrigeration Thermostat(3)D. 0344662 Defrost Limit Thermostat(4)( )E. 0461814 Relay Control Thermostat or(5)Fan and Anti-sweat Heater Thermostat ( )RELAYSF.

Merchandisers ® K E F C G B I A J D H M L RL with INNOVATOR Doors Technical Data Sheet P/N 0425644_P NSF® Certified November 2009 We reserve the right to change or revise specifications and

Tags:

  With, Sheet, Data, Technical, Doors, Technical data sheet, Innovators, Rl with innovator doors, Rl with innovator doors technical data sheet p

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Technical Data Sheet for RL with Innovator Doors - …

1 Merchandisers KEFCGBIAJDHMLRL with INNOVATORD oorsTechnical data SheetP/N 0425644_PNSF CertifiedNovember 2009We reserve the right to changeor revise specifications andproduct design in connectionwith any feature of our products. Such changes do not entitle the buyer to corresponding changes,improvements, additions orreplacements for equipmentpreviously sold or :Terminal block NOT for case-to-case wire connection!Item Part #DescriptionWiring Item #FANASSEMBLIES, StandardFan Assembly (1)0047000 Fan Motor, Evaporator ( )0461805 Fan Blade ( )12W Optional Energy EfficientFan Assembly (1)0477655 Fan Motor, Evaporator( )0461805 Fan Blade ( )B. 0474033 Standard Non-adjustable (2)Defrost Thermostat ( ) Adjustable Refrigeration Thermostat(3)D. 0344662 Defrost Limit Thermostat(4)( )E. 0461814 Relay Control Thermostat or(5)Fan and Anti-sweat Heater Thermostat ( )RELAYSF.

2 0342598 Anti-Sweat Control Relay (6)(120V) ( )G. 0342599 Fan Control Relay (208V)(7)( )HEATERSH. Electric Defrost Heaters Front (208V) (8)0484312 (1) 1 Door Models ( )0441755 (1) 2 Door Models ( )0441756 (1) 3 Door Models ( )0441757 (1) 4 Door Models ( )0441758 (1) 5 Door Models ( )Item Part #(Qty)Description Wiring Item #HEATERS(CONTINUED)H. Electric Defrost Heaters Rear (208V) (8)0484313 (1) 1 Door Models ( )0463891 (1) 2 Door Models ( )0463892 (1) 3 Door Models ( )0463893 (1) 4 Door Models ( )0463894 (1) 5 Door Models ( )I. Drain Pan Heater (9)Electric & KoolGas (120V)0489708 (1) 1 Door Models ( )0387036 (1) 2 Door Models ( )0387037 (1) 3 Door Models ( )0387038 (1) 4 Door Models ( )0387039 (1) 5 Door Models ( )LAMPS, BALLASTS, LED FIXTURES ANDPOWERSUPPLYJ.

3 0489698 2 Lamp Ballast ( )0489699 3 Lamp Ballast ( )0424649 Export Ballast ( ) Fluorescent LampReplace with like fixturesL. 0499399 LED Power Supply ( ) FixtureReplace with like fixturesNOTE: For LED lighting parts contact your Hussmannservice representative at 1-800-922-1919. Please haveyour model and serial number available. 2009 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 : Revision P updated electrical data , page to INNOVATORREACH-INGLASSDOORINSTALLATION ANDSERVICE manual, P/N 0425683, for Innovator and Innovator II door and framereplacement Dr2 Dr3 Dr4 Dr5 DrGeneral(A)Case Length (without ends or partitions)31 1/2 (800)62 (1575)92 1/2 (2350)122 7/8 (3121)153 3/8 (3896)(Each end adds 2 in. (51 mm) to length of lineup; each insulated partition adds 1 1/2in.)

4 (38 mm).Maximum O/S dimension of case back to front43 3/4 (1111)43 3/4 (1111)43 3/4 (1111)43 3/4 (1111)43 3/4 (1111)(Includes bumper. Add 26 1/2in. (673 mm) for door swing.)Back of case to rear of splashguard39 7/8 (1013)39 7/8 (1013) 39 7/8 (1013) 39 7/8 (1013) 39 7/8 (1013)Width of Skidrail3 3/4 (95)3 3/4 (95)3 3/4 (95)3 3/4 (95)3 3/4 (95)Width of Bottom Front Support6 (152)6 (152)6 (152)6 (152)6 (152)Stub-up area between front support and splashguard3 1/8 (79)3 1/8 (79)3 1/8 (79)3 1/8 (79)3 1/8 (79)Electrical Service RH end of case to the center of nearest knockout4 (102)4 (102)4 (102)4 (102)4 (102)RH end of case to the center of LH knockout27 1/2 (698)58 (1473)88 1/2 (2248)118 7/8 (3019)149 3/8 (3794)Back O/S of case to center of knockout41 5/8 (1058)41 5/8 (1058)41 5/8 (1058)41 5/8 (1058)41 5/8 (1058)* NOTE.

5 Electrical Field Wiring Connection Point is at Outlet(B)Right end of case to center of waste outlet15 3/4 (400)23 7/8 (606)54 1/4 (1378)46 1/4 (1175)76 5/8 (1946)Back O/S of case to center of waste outlet34 5/8 (879)34 5/8 (879)34 5/8 (879)34 5/8 (879)34 5/8 (879)Water SealEdge of water seal to center of waste outlet13 (330)13 (330)13 (330)13 (330)13 (330)Schedule 40 PVC drip pipe1 1/4 (32)1 1/4 (32)1 1/4 (32)1 1/4 (32)1 1/4 (32)** NOTE: Field installed water seal outlets, tees, and connectors are shipped with caseRefrigeration OutletRH end of case to center of RH refrigeration outlet5 3/8 (137)5 3/8 (137)5 3/8 (137)5 3/8 (137)5 3/8 (137)Back O/S of case to center of refrigeration outlet32 (813)32 (813)32 (813)32 (813)32 (813)Outside bottom front supports from end of case6 3/4(170)6 3/4(170)6 3/4(170)6 3/4(170)6 3/4(170) Center bottom front support from CenterlineNA24 (610)24 (610)24 (610)24 (610)Distance between Center and Outside supports will varyRL withInnovator Doors Technical data Sheet2 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 (102)43 3/4 (1111)Front 5-Door Shown6 (152)34 5/8 (879)32 (813)5 5/8 (143)41 5/8 (1057)Refrig.

6 OutletABElectrical WirewayBottom Front Support48 (1219)Waste OutletRelay & Terminal Block LocationSkid/ External Base13/4 (44)13/4 (44)7 (178)4 (102)SplashguardClearance for Door Swing26 1/2 (673)70 1/4 (1784)Dimensions shown as in. & (mm).Reach-In1, 2, 3, 4 & 5 DoorEngineeringPlan ViewsPHYSICAL DATAM erchandiser Drip Pipe (in.)1 1/4 Merchandiser Liquid Line (in.)3/8 Merchandiser Suction Line (in.)7/8RL - RM - RMFPlan View06-2009 REFRIGERATION DATANote: This data is based on store temperature andhumidity that does not exceed 75 F and 55% , 3, 4, 5 Door1 DoorFFICFFICD ischarge Air ( F) 5 122 5 Evaporator ( F) 11 19 11 19 Unit Sizing ( F) 14 22 14 22 Btu/hr/Door*Parallel1300 1370 1390 1470 Conventional1325 1400 1420 1590*Optional LED lighting reduces refrigeration loadby 100 Btu/ Energy Efficient Fan motors reducerefrigeration load by 109 Btu/ DATAALLFFICF requency (hr) 2424 Defrost Water (lb/Dr/day) ( 15% based on case configuration and productloading.)

7 ELECTRICFFICTemp Term ( F)48 48 Failsafe (minutes)4545 GASD uration (minutes)2020 OFFTIMENot Recommended CONVENTIONAL CONTROLSLow Pressure Backup ControlFFICCI/CO (Temp F)** 18 / 34 26 / 45 Indoor Unit Only, Pressure DefrostTermination (Temp F)** Not Recommended **Use a Temperature Pressure Chart to determinePSIG Charge (lb)** **This is an average for all refrigerant refrigerant charge may vary by approximate-ly half a Added to Lineup by each Standard End (in.)2 Optional End with Window (in.)1 1/2 Optional Partition (in.)1 1/2 Impact RLWith Innovator DoorsFrozen Food & Ice Cream4 3/4 (121)32 (813) 34 5/8 (879) 2 5/8 (67) 2 1/8 (54)Fan Coil62 1/2 (1588) 22 Shelf (559)41 (1041)27 7/8 (708) Refrigeration Outlet67 (1702) Frame 65 1/2 (1664) Door83 (2108)82 1/4 (2089)6 1/4 (159)13 1/8 (333) Frame41 7/8 (1064) 43 3/4 (1111) 3 1/2 (89)Dimensions shown as in.

8 & (mm).Reach-in 2, 3, 4 and 5 Door Models3 of 7P/N 0425644_PHUSSMANN CORPORATION BRIDGETON, MO 63044-2483 CertificationThis merchandiser model is manufactured to meet ANSI/NSF(National Sanitation Foundation) Standard #7 requirements forconstruction, materials & CORPORATION, Bridgeton, MO 63044-2483 DataNumber of Fans 12W12345 AmperesWattsMerchandiser1Dr2Dr3Dr4Dr5Dr1 Dr2Dr3Dr4Dr5 DrEvaporator Fan120V 60Hz 50Hz 60Hz 50Hz 60Hz Energy 60Hz Energy Anti-sweat Heaters (on fan circuit)120V 50/60Hz 50/60Hz Anti-sweat Heaters (on fan circuit)120V 50/60Hz 50/60Hz Circuit Ampacity120V 60Hz 50Hz 60Hz 50Hz 60Hz Energy 60Hz Energy Over Current Protection 120V2020202020 Maximum Over Current Protection 220V1515151515 DefrostDrain Heaters (120V) (Export: 220V 50 hz) Electric (Export: 220V 50 hz) Vertical Lighting1Dr2Dr3Dr4Dr5Dr1Dr2Dr3Dr4Dr5 DrInnovator* Doors (120V) (Export: 220V 50 hz) LED Lighting Hussmann EcoShine [27 W] (120V) EcoShine [27 W] [220V Export)] EcoShine EP [16 W] (120V) EcoShine EP [16 W] [220V Exp)] EcoShine [20 W] (120V) EcoShine [20 W] [220V Export)] (120V) (120V) [220V (Export)] * Innovator or Innovator IIRL withInnovator Doors Technical data Sheet4 of 7 Impact RLWith Innovator DoorsFrozen Food & Ice CreamHussmann recommends against frame heater cycling withInnovatordoors to prevent door seals from freezing to theframes and tearing.

9 5 of 7P/N 0425644_PHUSSMANN CORPORATION BRIDGETON, MO 63044-2483 RLWith Innovator DoorsFrozen Food & Ice CreamESTIMATED SHIPPING WEIGHT 4 CaseSolid End1 Dr2 Dr3 Dr4 Dr5 Dr(each)lb (kg)617 (280)997 (453)1295 (589)1595 (725)1874 (852)55 (25)4 Actual weights will vary according to optional kits DataRecommended Usable Cube 1 (Cu Ft/Dr) ft3 /Dr ( m3 /Dr)ARI Total Display Area 2 (Sq Ft/Dr) ft2/Dr ( m2 /Dr)Shelf Area 3(Sq Ft/Dr) ft2/Dr ( m2 /Dr)1 ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]2 Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch withInnovator Doors Technical data Sheet6 of 7OR120V POWERORS witchNEUTRAL1720 Defrost Termination ThermostatRefrigeration Thermostat (Optional)Pink23}To Condensing Relay CoilBREvaporator Fans1 Fan Relay F Heater (Drain) Controlc25 Fan Relay F Relay HeatersFrame Heaters21222PP2PP121110120V POWER1613 Evaporator Fan Relay Coil13 Rear Defrost HeaterRRC8 RRFront Defrost Limit208V208 VTerminal Blocks in RacewayLow Temperature with Electric Defrost2021222617123456 781011141316 LIGHTS (120V)DEFROST HEATERS (208V)CIRCLED NUMBERS = PARTS LIST ITEM NUMBERSTHESE ARE MARKER COLORS (WIRE MAY VARY.)

10 CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BL = Black LB = Light Blue BR =Brown Y =Yellow OR = Orange W = White Low Temperature242512 FANS & (120V)LIGHTS (Neutral)FANS & (Neutral)Permanent Internal JumpersRPWBRORRRRBKBKRRBKP2 PBK External Jumpers Termination ThermostatFIELD WIREDDBNEUTRALDark BlueRefer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683, for Innovator door and frame replacement Defrost Sequence - Low from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan Relay Coil (7).


Related search queries