GE Jenbacher GmbH & Co OHGA-6200 Jenbach, AustriaJMS 420 gas +43 5244 600-0 Fax +43 5244 63255 Jenbacher gas enginesTechnical SpecificationJMS 420 gas Module data:Additional information:Electrical outputkW pressure level (engine, average value 1m)dB(A)97 Recoverable thermal output (120 C) pressure level exhaust gas (1m, 30 off engindB(A)115 Energy gas mass flow rate, Consumption based on a LHV ofExhaust gas volume, wetNm ,5 kWh/Nm Nm exhaust back pressure after enginembar60 Electrical efficiency%41,9%Exhaust gas temperature at full load C [8]365 Thermal efficiency%44,2%Combustion air mass flow efficiency%86,2%Combustion air volumeNm to be dissipated (LT-Circuit)kW110 Max.)

JMS 420 GS-N.L Natural gas 1.415kW el. CO-GEN Module data: Additional information: Electrical output kW el. 1.415 Sound pressure level (engine, average value 1m) dB(A) 97

Tags:

  Specification, Technical, Technical specifications

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Technical Specification - cogeneration.com.ua

1 GE Jenbacher GmbH & Co OHGA-6200 Jenbach, AustriaJMS 420 gas +43 5244 600-0 Fax +43 5244 63255 Jenbacher gas enginesTechnical SpecificationJMS 420 gas Module data:Additional information:Electrical outputkW pressure level (engine, average value 1m)dB(A)97 Recoverable thermal output (120 C) pressure level exhaust gas (1m, 30 off engindB(A)115 Energy gas mass flow rate, Consumption based on a LHV ofExhaust gas volume, wetNm ,5 kWh/Nm Nm exhaust back pressure after enginembar60 Electrical efficiency%41,9%Exhaust gas temperature at full load C [8]365 Thermal efficiency%44,2%Combustion air mass flow efficiency%86,2%Combustion air volumeNm to be dissipated (LT-Circuit)kW110 Max.)

2 Inlet cooling water temp. (intercooler) C40 Emission values:Max. pressure drop in front of intake-air filtermbar10 NOx < 250 mg/Nm (5% O2) Return temperature C70 Forward temperature C90 Hot water flow ratem /h64,1 Engine data:Alternator:Engine typeJ 420 GS-A06 ManufacturerSTAMFORDC onfigurationV 70 TypePE 734 F2No. of cylinders20 Type displacementlit61,10 Efficiency at = 1,0%97,5%Nominal at = 0,8%96,6%Mean piston speedm/s9,25 Ratings at = 1, effe. press. at stand. power and nom. spebar19,00 Ratings at = 0, ratioEpsilon13,5 FrequencyHz50 ISO standard fuel stop power ICFN kW1451 VoltageV400 Spec.

3 Fuel consumption of enginekWh/kWh2,32 Protection ClassIP 23 Specific lube oil consumptiong/kWh0,30 Insulation classHWeight capacity lube on methane numberMZ85 Technical parameters:Applicable standards:Based on DIN-ISO 3046 Based on VDE 0530 REM with specified toleranceStandard conditions:Air pressure:1000 mbar or 100 m above sea levelAir temperature:25 C or 298 KRelative Humidity:30%Engine output derating:Gas quality:according to TA 1000-0300 Gas flow pressure:80 - 200 mbar(Lower gas pressures upon inquiry) Max. variation in gas pressure: 10%All data are based on engine full load at specified media temperatures and are subject to Technical Instruction TA 1100-0110 "PARAMETER FOR GE Jenbacher GAS ENGINES" must be strictly plants installed at > 500m above see level and/or intake temperature > 30 C, the reduction of engine power is determined for each gas enginesTechnical SpecificationBasic engine equipment:Module equipment.

4 *Exhaust gas turbocharger, Intercooler*Base frame for gas engine,*Motorized carburator for LEANOX control alternator and heat exchangers*Electronic contactless high performance ignition system*Internal pole alternator with excitation alternator and*Lubricating oil pump (gear driven) with automatic voltage regulator; 0,8 lagging to 1,0*Lubricating oil filters in main circuit*Flexible coupling, bell housing*Lubricating oil sump; Lubricating oil heat exchanger*Anti-vibration mounts*Jacket water pump*Air filter*Fuel-, lubricating oil and jacket water pipe work on engine*Automatic lube oil replenishing with level control*Flywheel for alternator operation.

5 Exhaust gas manifold*Wiring of components to module interface panel*Viscous damper*Crankcase breather*Knock sensors*Jacket water electric preheatingEngine accessories:*Electric starter motor*Electronic speed governor*Electronic speed monitoring device including starting and Module control panel: overspeed control*Totally enclosed , single door cubicle, wired to terminals and *Transducers and switches for oil pressure, jacket water temp., ready to operate, protection IP 41 outside, jacket water pressure, charge pressure and mixture temperature IP 10 inside, according to VDE-standards*One thermocouple per cylinderControl equipment:*Engine-Management-System (Dialog Network)Supplied loose: **Visualisation (industry PC-10'' color graphics display): Operation data,Gas train according to DIN-DVGW consisting of: controller display,Exh.

6 Gas temp.,Generator electr. connection,etc.*Manual stop valve, fuel gas filter, two solenoid valves, **Central engine- and module control: Speed-, Power output-, Leakage control device, gas pressure regulator LEANOX-Control and knock control, etc.*Multi-transducerDocumentation:*Lock able operation mode selector switch*Operating and maintenance manual Positions: "OFF", "MANUAL", "AUTOMATIC"*Spare parts manual*Demand switch*DrawingsAssembly, painting, testing in Jenbach/AustriaIdentical to Genset except that heat recovery is included.*jacket water heat exchanger mounted on module frame*exhaust gas heat exchanger mounted as separate heat recovery module*all heat exchangers with complete pipework*Heat exchangers and all inherent auxiliaries*Identical to module/genset but installed in 40' ISO container (65 dB(A) @ 10m); complete with all pipework and fittings*Twin circuit radation cooler for dissipation of intercooler jacket water and lube oil thermal output; ventilation equipment*Gas & smoke detectors; exhaust silencer; lube oil equipment; starting system.

7 Flexible connections*Seperate control room complete with generator switchgear and all internal power and monitoring cablesScope of Supply & Design Subject to Local Regulations and product development>>> Scope of supply container - JG(M)C 420 >>> Scope of supply genset - JGS 420 >>> Scope of supply module - JMS 420 gas enginesTechnical SpecificationGensetMain dimensions and weights (approximate value)Connections (at genset)Length water inlet and outletDN/PN100/10 Width gas outletDN/PN300/10 Height gas (at gas train)DN/PN80/16 Weight water connection:Weight Temperature CircuitDN/PN65/10 ModuleMain dimensions and weights (approximate value)Connections (at module)Length water inlet and outletDN/PN100/10 Width gas outletDN/PN300/10 Height gas (at gas train)DN/PN80/16 Weight water connection:Weight water-Inlet/Outlet 2nd stageDN/PN65/10 Heat recovery moduleMain dimensions and weights (approximate value)Connections (on heat recovery module)Width water inlet and outletDN/PN100/10 Height gas outletDN/PN300/10 Length drainDN/PN50/10 Drain line '' ''GE Jenbacher GmbH & Co OHGTel.

8 +43 5244 600-0A-6200 Jenbach, AustriaFax +43 5244 6325504. Jul gas enginesTechnical Specificatio