Example: stock market

Temperature Controller E5CS-X

e5cs -XE5CS-X1 Temperature Controller e5cs -X1/16 DIN Sized Multi-rangeController Offers SelectableControl Modes, Built-in AlarmnAccurate to of full scalenMultiple scale ranges allows flexibilityto match applicationnField-selectable Temperature ranges in F and CnSelectable ON/OFF and PID controlwith auto-tuning of proportional bandn8-function alarm, standardnTamper-proof setting, faulty sensorcompensation and controllerdiagnosticsnEasy-to-read 11 mm high LED displaynNonvolatile memory backupn 3-year warrantyOrdering Informationn Temperature CONTROLLERSC ontrol modesPID or ON/OFF actionSensor intputPlatinum RTD(Pt: 100 ,InterchangeabletypeThermocouple(DIN and JIS standard types)thermistor (THE types)OutputContactE5CS-R1 KJX-FE5CS-R1PX-FE5CS-R1GX-FVoltageE5CS-Q 1 KJX-FE5CS-Q1PX-FE5CS-Q1GX-Fn Temperature RANGEST hermocouple Input TypeInput typeType KType JSwitch setting01234566789 Temperature range 0 to 200 0 to 300 0 to 400 0 to 500 0 to)

E5CS-X E5CS-X 1 Temperature Controller E5CS-X 1/16 DIN Sized Multi-range Controller Offers Selectable Control Modes, Built-in Alarm Accurate to ±0.5% of full scale

Tags:

  Controller, Control, Temperatures, Temperature controller e5cs x, E5cs

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Temperature Controller E5CS-X

1 e5cs -XE5CS-X1 Temperature Controller e5cs -X1/16 DIN Sized Multi-rangeController Offers SelectableControl Modes, Built-in AlarmnAccurate to of full scalenMultiple scale ranges allows flexibilityto match applicationnField-selectable Temperature ranges in F and CnSelectable ON/OFF and PID controlwith auto-tuning of proportional bandn8-function alarm, standardnTamper-proof setting, faulty sensorcompensation and controllerdiagnosticsnEasy-to-read 11 mm high LED displaynNonvolatile memory backupn 3-year warrantyOrdering Informationn Temperature CONTROLLERSC ontrol modesPID or ON/OFF actionSensor intputPlatinum RTD(Pt: 100 ,InterchangeabletypeThermocouple(DIN and JIS standard types)thermistor (THE types))

2 OutputContactE5CS-R1 KJX-FE5CS-R1PX-FE5CS-R1GX-FVoltageE5CS-Q 1 KJX-FE5CS-Q1PX-FE5CS-Q1GX-Fn Temperature RANGEST hermocouple Input TypeInput typeType KType JSwitch setting01234566789 Temperature range 0 to 200 0 to 300 0 to 400 0 to 500 0 to 600 0 to 999 0 to 999 0 to 200 0 to 300 0 to 400 0 to 500 Scale indication C C C/ F C/ F C/ F C/ F F C C C/ F C/ FUnit of measure1 C or FPlatinum RTD Input TypeSwitch setting012345678 Temperature range-50 to to -20 to to 0 to 2000 to 3000 to 4000 to 6000 to 800 Scale indication C C C C/ F C/ F C C/ F F FUnit of measure1 C or FSwitch setting0123456789 Temperature range -50 to 500 to 100 50 to 150 100 to 200 150 to 300 -50 to 100 0 to 200 100 to 300 200 to 400 300 to 600 Scale indication C FUnit of measure1 C or FThermistor Input TypeE5CS-XE5CS-X2 DescriptionPart numberProtective coverHard plastic.

3 Protects front panel against dust, dirt and water dropsY92A-48n ACCESSORIESn REPLACEMENT PARTSD escriptionPart numberAdapter for panel mounting (supplied with each unit)Y92F-30 SpecificationsPart numberE5CS-q1 KJXE5CS-q1 PXE5CS-q1 GXSensor input typeThermocouplePlatinum RTD (Pt: 100 )ThermistorType J (IC) and Type K (CA)DIN or JIS standard(interchangeable type)Supply voltage100 to 240 VAC, 50/60 Hz; operates on 85 to 110% of rated volatePower consumptionApprox. 7 VAControlContactTypeSPDT relayoutputMax. load3 A, 250 VAC (resistive load)VoltageLogic load12 VDC, 20 mA with short-circuit of full scale during ON/OFF control actionResponseOutput2 seconds for output to changetimeDisplay2 seconds for displayed indication to changeServiceMechanical10 million operations minimum with contact outputlifeElectrical100,000 operations minimum with contact outputAlarm outputTypeSPST-NO relayMax.

4 Load1 A, 250 VAC (resistive load)SettingAbsolute value alarm: Same as control output setting rangerangeOthers: 0 to full scaleSetting accuracySet value coincides with indicated value, so no relative error existsIndication accuracy of full scale, 1 digit Range-999 to 999 (Limited to input type)ControlTypeON/OFF and PID with automatic tuning of proportional band, switch selectablemodesProportional band3 to 20% (in PID mode) automatically adjusted according to the rise time of thecontrolled systemReset time4 minutes (in PID mode)Rate minutes (in PID mode)Proportional period2 or 20 seconds, switch selectableSampling period500 msMaterialsPlastic caseMountingFits 1/16 DIN panel cutout.

5 Includes panle mounting adapterConnectionsScrew terminalsWeight170 g (6 oz.) without mounting adapterEnclosureFront panelIP50, NEMA 4 with optional cover Y92A-48 NratingsRear panelIP30 TerminalsIP00 ApprovalsULRecognized, File Number E68481 CSAC ertified, File Number LR59623 AmbientOperating-10 to 55 C (14 to 131 F)temperatureStorage-25 to 65 C (-13 to 149 F)Humidity35 to 85% RHInsulation resistance20 M minimum at 500 VDCD ielectric strength2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminals of different polarityVibrationMechanical durability10 to 55 Hz, mm ( in) double amplitude in X, Y, and Z directions for 2 hours eachMalfunction durability2 to 55 Hz, 2 G in X, Y, and Z directions for 10 minutes eachShockMechanical durability30 m/s2, in 6 directions, 3 times eachMalfunction durability100 m/s2, in 6 directions, 3 times eachE5CS-XE5CS-X3 DimensionsUnit: mm (inch)Panel CutoutMax.

6 60( )45( )+ ( )+ +1-0+1-0+1-0+1-0+1-0L=(48 x block )for tight side-by-side mounting+1-0 Note:1. Recommended panel thickness is 1 to 8 mm ( in).2. Because mounting brackets are attached to the topand bottom of a Temperature Controller , tight side-by-side mounting is Mounting of Several Temperature ControllersL45( )+ ( )90 ( )10( )6( )nn48( )Nomenclature1. Main display2. control output indicator3. Alarm indicator4. Up key5. Down key7. Write protection key8. Display data identifier9. Deviation indicators6. Return keyKeyDescription7 The hidden write protection key provides protectionagainst unauthorized to set temperatures and isused in conjunction with the internal "protection"switch.

7 If the internal protection switch is set to ON,then to obtain Up and Down operation, the hiddenkey must be pressed simultaneously with the Up andDown keys. If the internal protection switch is set toOFF, changes can be made simply by pressing theUp and Down data identifier lights SP when the settemperature is displayed on the main display and ALwhen an alarm value is deviation indicators light an up arrow when thepresent Temperature is higher than the set tempera-ture and light a down arrow when the present valueis lower than the set Temperature . The green blockindicates the Temperature deviation is within 1% ofthe full display sequentially displays the presenttemperature, set Temperature , and an alarm valueeach time the return key is output indicator lights when the output is indicator lights when the alarm output is key increases the set Temperature or alarm valuewhen pressed.

8 Increases the value quickly whenheld key decreases the set Temperature or alarmvalue when pressed. Decreases the value quicklywhen held key changes the value displayed on the maindisplay each time output type20 mA, 12 VDCC ontact output type 100 to 240 VAC, 50/60 HzAlarm outputThermocouple input typePlatinum RTD input typeThermistor input typeOmron Europe EMA-ISD, tel:+31 23 5681390, fax:+31 23 5681397, No. GC TC11 7/97 Specifications subject to change without notice. Printed in the