Technical Data Effective November 5, 2014. OAWC-P Passive Infrared Wall/Corner sensor Catalog# Prepared by Overview Project Date The Passive Infrared Low Voltage Occupancy Sensing Wall/Corner Comments Type sensor is a motion sensing lighting control that is used for energy savings and convenience. Features Self-Adjusting time delay and sensitivity Optional built-in light level sensor Optional BAS/HVAC isolated relay NEMA WD7 Guide robotic method utilized to verify coverage patterns Manual On feature for use with 1 or 2 momentary switches controlling 1 or more Switchpacks (GMD switch). Selectable Walk-Through Mode PIR Self-Adjusting Activated Technical Data OAWC-P Passive Infrared Wall/Corner sensor . November 2014 .. Specifications Description/Operation The sensor is designed to detect motion from a heat-emitting source Technology Passive Infrared (PIR) (such as a person entering a room) within its field-of-view and Power Input automatically switch lights ON.

Tenial aa ffeive oveer 14 OAWC-P – Passive Infrared Wall/Corner Sensor Overview The Passive Infrared Low Voltage Occupancy Sensing Wall/Corner sensor is a motion sensing lighting control that is used for energy

Tags:

  Walls, Infrared, Sensor, Passive, Corners, Passive infrared, Passive infrared wall, P passive infrared wall corner sensor

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Tenial aa Technical Data OAWC-P – Passive Infrared Wall ...

1 Technical Data Effective November 5, 2014. OAWC-P Passive Infrared Wall/Corner sensor Catalog# Prepared by Overview Project Date The Passive Infrared Low Voltage Occupancy Sensing Wall/Corner Comments Type sensor is a motion sensing lighting control that is used for energy savings and convenience. Features Self-Adjusting time delay and sensitivity Optional built-in light level sensor Optional BAS/HVAC isolated relay NEMA WD7 Guide robotic method utilized to verify coverage patterns Manual On feature for use with 1 or 2 momentary switches controlling 1 or more Switchpacks (GMD switch). Selectable Walk-Through Mode PIR Self-Adjusting Activated Technical Data OAWC-P Passive Infrared Wall/Corner sensor . November 2014 .. Specifications Description/Operation The sensor is designed to detect motion from a heat-emitting source Technology Passive Infrared (PIR) (such as a person entering a room) within its field-of-view and Power Input automatically switch lights ON.

2 These sensors have multi-segmented Requirements 0-30 VDC from Greengate Switchpack or Greengate lenses. For units to sense motion, the person must cross between System two segments. The distance between segments increases the Maximum current needed is 25 mA per sensor farther you are from the sensor , so motion has to be larger the farther you are from the unit. PIR sensors are considered line-of Output sight sensors, meaning that the sensor must be able to have a direct Open collector output to switch up to ten line-of-sight to the person making the motion. The sensor includes Greengate Switchpacks self-adaptive technology that continuously self-adjusts sensitivity and Isolated Form C Relay in (-R models) time delay in real-time, maximizing the potential energy savings that Isolated Form C Relay Ratings: 1A 30 VDC/VAC are available in the particular application. In Automatic On Mode, the lights turn ON when a person enters the room.

3 In Manual On Mode, Time Delays Self-Adjusting, 15 seconds/test, 5, 10, 15, 30 minutes the lights are turned ON by activating a momentary switch (model # GMDS-*) that is connected to the sensor . When used with 2. Light Level 0 to 300 foot-candles level lighting (-R model only), Bi-level Automatic On can be achieved Sensing which allows Zone 1 to come on automatically upon occupancy. (-R Models). Zone 2 does not come on unless the occupant presses the optional Operating Temperature: 32 F - 104 F (0 C - 40 C) momentary switch. When enabled, the daylighting feature (-R. Environment Relative humidity: 20% to 90% Non-condensing models only) prevents lights from turning ON when the room is For indoor use only adequately illuminated by natural light. Housing Durable, injection molded housing. Polycarbonate resin complies with UL 94V-0 Applications Size H x W x 2 D (112mm x x ) Offices Mounting Mounts directly to ceiling tile, to a 4 square box Conference Rooms and round mud ring or to 4 octagon box Storage Areas LED Indicators Red LED for PIR detection Common Areas Standards FCC Compliant cULus Listed Other Indoor Office RoHS Compliant Aisles/Hallways 2 OAWC-P Passive Infrared Wall/Corner sensor Technical Data November 2014.

4 Wiring Diagrams OAWC-P -120W-R, OAWC-P -009-H-R Models HOT. LINE. NEUTRAL. **USE BLACK LEAD FOR 120 VAC. WHITE. USE ORANGE LEAD FOR 277 VAC. **HOT. BLUE. CAP UNUSED LEAD. LOAD "A". RED (15 VDC). SWITCH- PACK BLUE. BLUE (CONTROL). BLACK (COMMON). MANUAL MODE OPERATION: RED (10-30 VDC). HOT. 1. SWITCHES ARE REQUIRED TO TURN BLUE (CONTROL-OCC). CORRESPONDING LOADS ON. LINE. BLACK (COMMON) NEUTRAL. 2. LOADS TURN OFF WHEN sensor . TIMES OUT OR WITH SWITCHES. YELLOW (CONTROL-OCC/DAY) **USE BLACK LEAD FOR 120 VAC. AUTOMATIC MODE OPERATION: WHITE. USE ORANGE LEAD FOR 277 VAC. **HOT. BLUE. BROWN (BLUE CONTROL) CAP UNUSED LEAD. 1. WHEN sensor ACTIVATES, BOTH LOAD "B". LOADS TURN ON. BROWN/WHITE (YELLOW CONTROL). RED (15 VDC) SWITCH- 2. SWITCHES CAN BE USED TO TURN. LOADS ON OR OFF. PACK BLUE. BLUE (CONTROL). 3. IF DAYLIGHT sensor IS ENABLED AND. LIGHT LEVEL IS ABOVE SETPOINT, BLACK (COMMON).

5 SWITCHPACK CONNECTED TO YELLOW. LEAD WILL NOT TURN LOAD ON. RECOMMENDED WIRE: 18-3 AWG STRANDED WIRE SHIELDED OR. NON/SHIELDED MODEL GMDS - LOAD "B". PURPLE (NORMALLY CLOSED). (NORMALLY OPEN. MOMENTARY SWITCH) NOTES. GRAY (ISOLATED RELAY COMMON). 1. LOADS MAY BE ON SAME. CIRCUIT OR DIFFERENT. ORANGE (NORMALLY OPEN) CIRCUITS OR VOLTAGES. 2. SP20-MV SWITCHPACK SHOWN. *Wiring diagram for single sensor application. 120/277 VAC 20 AMP RATING. MODEL GMDS - LOAD "A". Visit our website for other wiring diagrams. (NORMALLY OPEN. MOMENTARY SWITCH). Coverage 1200 Sq. ft coverage 90 linear ft coverage . 10 m (33 ft). 16'. 5m ( ). (16 ft). Maximum coverage area may vary somewhat according to room Minor Motion, IR. shape and the presence of obstacles. 0. Major Motion, IR. 0. 16'. ( ). 5m (16 ft). ( mm). 10 m (33 ft). m 3 ft 7 ft 10 ft 43 ft 75 ft 92 ft (10 ft). (1 mm) ( mm) (3 mm) ( mm) (23 mm) (28 mm).

6 M m m m (6 ft) (15 ft) (25 ft) (50 ft). 3. Technical Data OAWC-P Passive Infrared Wall/Corner sensor .. Controls DIP Switch Legend DIP Switch Legend Time Delay Activation Activation PIR Sensitivity Walk-Through Mode LEDs Override Lighting Sweep Daylighting Mode DIP Switch Power Pack One Power Pack Two (-R model only) (-R model only). Activation *Self-Adjusts to 1 3 4 PIR 5. 10 min. user mode Default =. 1 2 3 4 5 6 7 8 9 10. 9715-000004-00. Ordering Catalog # Coverage Field of View Features OAWC-P -120W-R 1,200 sq. ft. Wide Angle, 120 w/ BAS Relay and Daylight sensor OAWC-P -009L-H-R 90 linear ft. 180 w/ BAS Relay and Daylight sensor OAWC-P -120W 1,200 sq. ft. Wide Angle, 120 . OAWC-P -009L-H 90 linear ft. 180 . Eaton 1000 Eaton Boulevard Cleveland, OH 44122. United States Eaton's Cooper Controls Business 203 Cooper Circle Peachtree City, GA 30269. 2014 Eaton All Rights Reserved Eaton is a registered trademark.

7 Printed in USA. Publication No. ACC141016 All other trademarks are property November 5, 2014 of their respective owners.