PyrogenThe AerosolFire Supression SystemPyroshieldSpecialistFire ProtectionNow availableexclusively from off-shoreA revolution is taking place in fire Suppression. Developed from solidrocket fuel technology, Pyrogen is the world's first commercially availableAerosol fire Extinguishing System . Designed as a safe & practicalalternative to Halon, Halocarbons, Chemical Powders and Inert GasesPyrogen is available from stock in a wide range of canister sizes. Pyrogenis an inert non-toxic solid that remains stable until electrically or thermallyactivated, where upon it produces a gas-like extinguishing Aerosol . Theaerosol attacks the fire chemically and physically, giving virtual instantextinguishment & preventing re-ignition, and in certain instances,explosions. For many applications Pyrogen is the only practicalalternative to installed close to the potential hazardSome of the sizes availableWhen electrically or thermally ignited, Pyrogengenerates the fire extinguishing aerosolEasily reinstalled within minutesSpecialist fire ProtectionPyroshieldSuppliers of The PyrogenAerosol Supression System 3 times more effective than a maximum* design concentration of 100g per m3 Pyrogen exhibits equal or better extinguishingproperties than Halon 1301 at 330g per m volume),as certified by Scientific Services has the lowest extinguishing concentrationamongst commercially

o f f - s h o r e A revolution is taking place in Fire Suppression. Developed from solid rocket fuel technology, Pyrogen is the world's first commercially available

Tags:

  System, Fire, Aerosol, The aerosol fire supression system, Supression

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of The Aerosol Fire Supression System - Pyrogen

1 PyrogenThe AerosolFire Supression SystemPyroshieldSpecialistFire ProtectionNow availableexclusively from off-shoreA revolution is taking place in fire Suppression. Developed from solidrocket fuel technology, Pyrogen is the world's first commercially availableAerosol fire Extinguishing System . Designed as a safe & practicalalternative to Halon, Halocarbons, Chemical Powders and Inert GasesPyrogen is available from stock in a wide range of canister sizes. Pyrogenis an inert non-toxic solid that remains stable until electrically or thermallyactivated, where upon it produces a gas-like extinguishing Aerosol . Theaerosol attacks the fire chemically and physically, giving virtual instantextinguishment & preventing re-ignition, and in certain instances,explosions. For many applications Pyrogen is the only practicalalternative to installed close to the potential hazardSome of the sizes availableWhen electrically or thermally ignited, Pyrogengenerates the fire extinguishing aerosolEasily reinstalled within minutesSpecialist fire ProtectionPyroshieldSuppliers of The PyrogenAerosol Supression System 3 times more effective than a maximum* design concentration of 100g per m3 Pyrogen exhibits equal or better extinguishingproperties than Halon 1301 at 330g per m volume),as certified by Scientific Services has the lowest extinguishing concentrationamongst commercially available agents.

2 *Recommendedmaximum for Class A, B, C, E & F type fires. Refer to table on FriendlyNo Pressurised Cylinders or Pipe & certificationCompact & Weight to Install & EffectiveBenefits of Pyrogenmachineryandautomationequipmentpl antmachineryHALONPYROGENHALONHALONTESTED TESTEDTESTEDI nertgasPYROGENH alon 1301FM-200FE-13CO2 Pyrogen has been certified as having Zero OzoneDepleting Potential (ODP) & Zero Global WarmingPotential (GWP). It is officially listed by the USEnvironmental Protection Authority under itsHalon replacement Significant New AlternativesProgram (SNAP). Pyrogen Canisters are self contained, zero pressureunits. As well as being light & safe to transport, theyrequire no additional pipes, nozzles or distributionequipment. They cannot leak, burst or deteriorate,and can be stored for up to 10 years has been tested by LPC, Scientific ServiceLaboratories (Australia) and is undergoing furthercertification worldwide.

3 For the latest approvallistings and test data please contact your nearestPyrogen canisters can provide the smallest &lightest fire extinguishing System currently space requirements of up to 1/40th of Inertgases, and weight penalties of often only 10% ofcompeting systems, Pyrogen in many cases is theonly practical Halon canisters are electrically (or automaticallythermally) activated. Simple wiring & plug inconnectors can reduce installation times to a 1/3rdor less. If discharged, new canisters may bereinstalled in minutes* affording minimal downtimeand eliminate potentially hazardous periods ofnon-active fire suppression .*Providing all and any necessary safety checks & inspections have been some Halon alternatives, Pyrogen producesno aggressive acids such as Hydrogen Fluorideupon contact with hot surfaces. Pyrogen producesno chlorine or bromide and does not depleteoxygen to suppress the minimal space & weight requirements, simpleinstallation, zero maintenance and up to 10 yearsservice life, Pyrogen is arguably the most costeffective Halon alternative available.

4 How it workselectricalcabinetsmilitaryvehicless hippingandmarineCombustible label coverDirectional plateCoolant gridChemical coolantSeparator gridThermal ignition deviceSpacer ringSolid Aerosol generatingcompositionElectrical ignition deviceHeavy duty aluminiumalloy castingIgniter circuit connectorCanister construction3 potential methods of actuationCanister heated 500oCNaked flameorheat 175oCviafire conducting cordElectrical signalfromcontrol panelAerosol generatedChemical coolant decomposes absorbing heatFire fightingaerosol rapidly generatedDecomposed chemical coolantAerosol distributedNaked flameviapyrotechnic fuseTotal floodingaerosol demonstrates 3dgas like upto 60 reaction within the canisterPrinciple of the chemical reation suppressing the fireO2O2O2 OHOH(CnHm)FUELHEATO2O2O2 OOOKKKKKKKHHOHH(CnHm)PyrogenFUELHEATO2O2 O2(CnHm)Flame chain brokenFUELThe principle of extinguishing action employed by Pyrogen isunique - a special solid chemical, when electrically or thermallyignited, produces combustion products - micron size drychemical particles and gases.

5 Dry chemical particles, (mainlypotassium carbonates), and gaseous mixture, (mainly carbondioxide, nitrogen and water vapour), mix together into a uniformfire extinguishing Aerosol . Before being released into a protectedarea, the hot Aerosol propels itself through a unique solidchemical coolant, which decomposes absorbing huge amountsof heat, thus ensuring flameless discharge and uniform distributionof the cool Aerosol within the high rate of Aerosol discharge ensures a tremendous knockdowneffect. Micron size Aerosol particles exhibit gas-like threedimensionalqualities that allow the agent to rapidly distributethroughout enclosure and reach even the most concealed andshielded locations. Homogeneous distribution is achieved in amatter of seconds, while long holding times all help to preventfire 3K radicals attach themselves to O, H & OHand remove them from the flame chainwithoutdepleting OxygenStage 2 Pyrogen Aerosol introduces potassiumradicals (K) into the flame chain reactionStage 1 fire is propagated by the'flame chain carriers' O, H & OHSupervision/Monitoring Circuit:1mAActivation (Electrical):400mA @6/12/24v for 10mSActivation (Thermal):175 CConnector.

6 4 pin Military Type 2 PMDTA nalog MIL-C-5015 Technical dataCanister CharacteristicsAerosol Characteristics(at maximum design concentration)Electrical (Thermal) CharacteristicsClassifications* Pyrogen has been certified as low toxicity by the Academy of Science & Biophysics Institute, tableAgentFormula%ODPGWP(100yrs vsCO2 =1)Atmosphericlifetimes (yrs)Extinguishing concentration(Class B fires)Halon 1301FM-200 NAF S IIIFE-13FE-25 ArgoniteArgotecInergenCarbon dioxideWaterChemical offire suppressionChemicalphysicalphysicalphysi calphysicalphysicalphysicalphysicalphysi calphysicalchemical or physicalPYROGENKNO3 Plasticised *00---100chemicalbusandhgvenginebaysoffr oadvehiclesCanister Material:Marine Grade Aluminium AlloySurface Treatment:Powder Coated (red)Max/Min Ambient-50 C ~ +60 CShock:Tested at 10g for >13,000 impactsVibration:5g @ 50~250 HzCorrosion Resistance:Greater than UL 1058 Impact Resistance:IP558 Humidity:96%_>_>Potassium Carbonates, solid:~ 7g/m3 Nitrogen Gas:~ 70% by Dioxide Gas:~ by volCarbon Monoxide Gas:~ by volNitrogen Oxides, Gas:40 100 ppmAmmonia, Gas:~ by volTemp at Nozzle + 500mm:75 COxygen (level)17% to 20% (typical)Holding time60 mins_<_<Suitable for fire :Class A - Combustible SolidsClass B - Flammable LiquidsClass C - Flammable GasesClass E - Electrically Energised FiresClass F - Fats & Cooking OilsHandling & Transport:Accordance with UN 1325 &Dangerous Goods Code: :2[Y]EPackaging Group.

7 III_<_< Installation dataPyroshield (UK) fire panelsAccessoriesHealth & Safety StatementAvailable sizesParameterMass of generator, gMass of Aerosol formingcomposition, gMax protected volume, m3@ 100g/m3 Nozzle outletLength, mmDiameter, mmDischarge time, < < < < ,5001,00010bi-35095< ,8305005mono-19095< ,0001,50012mono-180247< ,5002,20017mono-247247< ,0003,50027mono-235306< ,0006,00046mono-260402< ,0006,50050mono-175492< ,0008,40065mono-227492< ,00011,00085mono-285492< due to the high obscuration, Pyrogen is designed for use in normally unoccupied areas such as data rooms, machinery and engine spaces, controlcabinets and storage areas. Inadvertent exposure to the Aerosol should be avoided using normal precautions such as warning signals, pre-discharge alarmand post-discharge warning and venting. Accidental exposure to Aerosol should be limited to 5 obscuration may impede the egress of personnel, hold off devices may be required for large areas or those with internal obstructions.

8 Further details on thesafe application, installation, operation and recommissioning of Pyrogen systems is given in the design manual and a manufacturers safety data sheetisavailable upon Westbrook Trading Est.,Westbrook Road, Trafford park,Manchester (UK) M17 1 AYTelephone: +44 (0)161 877 0077 Fax: +44 (0)161 877 0078E-mail: New Premises at TraffordPark of Pyroshield's PyroSense Detection,Alarm & Activation Control Panel range,covering both Industrial & Marine ApplicationsPyroshieldA complete range of accessories areavailable to ficiltate complete installtions