Example: bankruptcy

The Spectroquant Analysis System - AMCO …

The Spectroquant Analysis SystemSafety in water analysisMRight on target every is today a decisive factor in water and wastewater Analysis after all, the measurement resultsmust be reliable. Our extensive range of tools forquality assurance ensure that thevalues that you record in your measurements become secure, reproducible, and officially recog-nized analytical kitsPhotometersSample preparationGuaranteed qualityTested qualityQuality assurance from start to finishFor us, quality starts with the production of our checks ensure a consistently high We give you thisguarantee in writing, too.

Right on target every time. Quality is today a decisive factor in water and wastewater analysis – after all, the measurement results must be reliable.

Tags:

  Analysis, System, The spectroquant analysis system, Spectroquant

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of The Spectroquant Analysis System - AMCO …

1 The Spectroquant Analysis SystemSafety in water analysisMRight on target every is today a decisive factor in water and wastewater Analysis after all, the measurement resultsmust be reliable. Our extensive range of tools forquality assurance ensure that thevalues that you record in your measurements become secure, reproducible, and officially recog-nized analytical kitsPhotometersSample preparationGuaranteed qualityTested qualityQuality assurance from start to finishFor us, quality starts with the production of our checks ensure a consistently high We give you thisguarantee in writing, too.

2 Lot certificate, quality certificate, test seal, and validation of theanalytical methods are signs ofour commitment to to make it easier for you to check the quality whenever you wish to, we also offer a comprehensive range of equip-ment. Using the PhotoCheck,CombiCheck, and PipeCheck products and the thermosensorsyou can check the quality of your working materials and modeof operation from start to when the safety of the overall System is given it is possible to guarantee the accuracy of your is the red threadDocumentationServiceIt's readily apparent that the overall System is secure and accurate only when each part ofthe System meshes well with theothers and the quality demandsare met by each component of the System .

3 The overall System is more thanmerely the sum of its parts. Easy to handle, an excellent step-by-step description of the workingprocedure, and thus safety in their use these are the features that characterize the Spectroquant testkits. The calibration is another aspectthat no longer need concern you: all test kits are already stored in of the colour reaction:Simply. Comprehensive. A made-to-measure test kit for every analytical task. +=Sample(Cu ion)blue colorantdye which is measured in the photometerReagent(Cuprizone)Test kitsTasks in the area of environmentalanalysis are comprehensivelycovered: no matter whether you'redealing with drinking water, surface water, process water,municipal or industrial waste-water, disposal drainage water,refuse, or soils there are over120 different Spectroquant testkits and numerous applicationsavailable representing competentsolutions all out of one hand.

4 The range of parameters has beentuned to the special requirementsof everyday practice and isexpanded parameterssuch as COD are con-ventional parameters. The chemistry employedby the Spectroquant test kits conforms with the relevant standards and bears the USEPAA pproved seal issued by the American Environ-mental Protection Agency. Seven different measuringranges for COD enableyou to obtain accurateresults without having to dilute samples. Nutrientssuch as N and P are ofmajor relevance in allwater bodies. The stepsfor the pretreatment ofsamples necessary toensure that the total contents are measuredare already integrated in the Spectroquant Cell substancessuch as cadmium, chromate, cyanide, andlead must be detectableeven in the trace range another aspect fulfilled by the Spectroquant test metalsare other substances thatmust be detected in electroplating and textile-industrial wastewater.

5 An optimal sample pre-treatment is absolutelyessential in this connec-tion. Spectroquant Crack Sets ensure thecomplete digestion ofsamples as nitrate, nitrite,chloride, fluoride, andsulfate are of essentialrelevance not only in thearea of drinking-watersupply. A practically oriented selection ofSpectroquant test kitsleaves no question Spectroquant analyticalmethods are validated, meaningthat the quality is defined and certified. The validation data are determined for everySpectroquant test kit and documented in the validation Cell Tests One of the outstanding features ofour Cell Tests is their user-friendlyhandling.

6 Virtually all of the reagents needed for the analysisare already contained predosed inthe cell. The barcode on each cellidentifies it unmistakably. Whenthe cell is inserted into the photo-meter, the barcode enables thecorrect method to be selectedautomatically, virtually preventingthe occurrence of mix-ups at Legally secure. The validation of an analytical method is an absolute MUST in this day and age. Validation means legal security. Reaction cellsThe cells are made of special high-quality glasswith excellent opticalcharacteristics.

7 Additional reagentsOther reagents that arerequired for the determi-nation or for the sample pretreatment are containedin easy-to-handle labelParameters and cataloguenumber, hazard warnings,the contents, and mostimportantly the barcode a lot of information in asmall leafletAll the information youneed for example thereaction principle, preciseworking instructions, areaand scope of application,influence of foreign ions,data on the accuracy all presented conciselyin the package packaging providesideal protection for the cells during ship-ment as well as againsttemperature variationsand moisture.

8 The outerlabel provides importantinformation on the con-tents and also gives safetyadvice. Hazard warningsin both symbol form aswell as in writing, thebatch number, and theshelf-life of the test kit(up to three years) all at a TestsCat. No. , freeChlorine, free and totalChromateChromium, totalCODCODCODCODCODCODCODCOD (Hg-free)COD (Hg-free)CopperCyanideFluorideFormaldehy deHydrogen peroxideIronIron (II) and (III)LeadMagnesiumManganeseMolybdenumNic kelNitrateNitrateNitrateNitrateNitrate in seawaterNitriteNitrogen, totalNitrogen, totalNitrogen, totalOxygenPhenolePhosphatePhosphorus, totalPhosphatePhosphorus, totalPhosphatePhosphatePotassiumPotassiu mResidual HardnessSodiumSulfateSulfateSulfateSulfi teSurfactants.

9 AnionicTinTOCTOCT otal hardnessZincZincMeasuring g/l mg/l mg/l mg/l mg/l mg/l mg/l 3000 mg/l mg/l Ca10 250 mg/l Ca 5 125 mg/l mg/l mg/l mg/l mg/l mg/l COD10 150 mg/l COD15 300 mg/l COD50 500 mg/l COD25 1500 mg/l COD300 3500 mg/l COD500 10 000 mg/l COD10 150 mg/l COD100 1500 mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l NO3-N23 225 mg/l mg/l mg/l NO2-N mg/l mg/l N10 150 mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l mg/l K30 300 mg/l mg/l Ca10 300 mg/l Na5 250 mg/l SO450 500 mg/l SO4100 1000 mg/l mg/l mg/l mg/l mg/l TOC50 800 mg/l TOC5 215 mg/l mg/l mg/l ZnMethodEnzymatical reactionIndophenol blueIndophenol blueIndophenol blueIndophenol blueOxidation to chlorideAzomethine HModification of

10 Winkler methodCadion-DerivatPhthaleinkomplexoneI ron(III)-thiocyanateDPDDPDD iphenylcarbazideOxidation, DiphenylcarbazideChromosulfuric acid oxidationChromosulfuric acid oxidationChromosulfuric acid oxidationChromosulfuric acid oxidationChromosulfuric acid oxidationChromosulfuric acid oxidationChromosulfuric acid oxidationChromosulfuric acid oxidationChromosulfuric acid oxidationCuprizoneBarbituric acid and pyridinecarboxylic acidAlizarinkomplexoneChromotropic acidTitanyl -DipyridylPARP hthaleinkomplexoneFormaldoximeBromopyrog allol ReactionOxidation, , NitrospectralOxidation.


Related search queries