THE WALL-MOUNT™ ONE TON AIR CONDITIONER

THE WALL- mount ONE TON AIR CONDITIONER . W12 AAA 60Hz Green Refrigerant 12,000 Btuh EER. Right Side Control Panel R-410A. The Bard Wall- mount One Ton Air CONDITIONER is a self contained energy efficient heating and cooling system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. The One Ton is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities.

Form No. S3485-316 Supersedes S3485-614 Page 1 of 6 THE WALL-MOUNT™ ONE TON AIR CONDITIONER The Bard Wall-Mount One Ton Air Conditioner is a self contained energy

Tags:

  Mount, Conditioners, Mount one ton air conditioner, One ton air conditioner

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of THE WALL-MOUNT™ ONE TON AIR CONDITIONER

1 THE WALL- mount ONE TON AIR CONDITIONER . W12 AAA 60Hz Green Refrigerant 12,000 Btuh EER. Right Side Control Panel R-410A. The Bard Wall- mount One Ton Air CONDITIONER is a self contained energy efficient heating and cooling system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. The One Ton is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities.

2 Factory or field installed accessories are available to meet specific job requirements. Engineered Features Aluminum Finned Copper Coils One Inch, Disposable Air Filter: Rifled tubing and enhanced louvered fin Easily removed for replacement from for maximum heat transfer and energy the outside. Optional two-inch pleated efficiency. filter, factory or field installed. Quiet Twin Blowers: Top Rain Flashing: Designed to accept full ducted system or Standard feature on all models. for non-ducted free blow installations.

3 Slope Top: High Efficiency Rotary Compressor Standard feature for water run-off. R-410A Refrigerant: Compressor Control Module: Designed with R-410A (HFC) non-ozone Standard on all units. Built-in off- depleting refrigerant in compliance with delay timer adjustable from 30 seconds the Montreal protocol and 2010 EPA to 5-minutes. 2-minute on-delay if requirements. power interrupt. 120-second bypass for low pressure control, and both soft Liquid Line Filter Drier: and manual lockouts for high and low Standard on all units.

4 Protects system pressure controls. Alarm output for against moisture. alarm relay. Galvanized 20 Gauge Zinc Coated High & Low Pressure Switches are Steel Cabinet: Auto-Reset: Cleaned, rinsed, sealed and dried before Standard on all units. Built-in lockout the polyurethane primer is applied. The circuit resets from the room thermostat. cabinet is handsomely finished with a Provides commercial quality protection baked on textured enamel, which allows to the compressor. it to withstand 1000 hours of salt spray tests per ASTM B117-03.

5 Barometric Fresh Air Damper: Allows up to 100 CFM of fresh air. Electrical Components: Are easily accessible for routine Full Length Mounting Flanges: inspection and maintenance through a Built into cabinet for improved right side, service panel opening. appearance and easy installation. Circuit Breaker: Standard on 230/208 Models. Optional Product Features Alarm Relay: Fully Modulating Economizer: Dry contacts for remote alarm on Can be factory or field installed. high or low pressure lockouts. Commercial Room Ventilator: Low Ambient Control: Can be factory or field installed.

6 Permits operation down to 0 F. outdoor ambient. Can be factory or field installed. Complies with efficiency requirements of ANSI/ASHRAE/IESNA Certified to ANSI/ARI Standard 390-2003 for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL. 1995/CSA No. 236-05, Fourth Edition. Commercial Product - Not intended for Residential application. Form No. S3485-316. Supersedes S3485-614. Page 1 of 6. Capacity and Efficiency Ratings Models Volts Phase Heat Strip Cooling Cap BTUH j EER k W12 AAAA0Z 230/208 1 NONE 12,000 W12 AAAA03 230/208 1 KW 12,000 W12 AAAA05 230/208 1 KW 12,000 W12 AAAK00 115 1 NONE 12,000 W12 AAAK02 115 1 KW 12,000 Capacity is certified in accordance with ANSI/ARI Standard 390-2003.

7 EER = Energy Efficiency Ratio and is certified in accordance with ANSI/ARI Standard 390-2003. All ratings based on fresh air intake being 100% closed (no outside air introduction). Electrical Specifications Rated Volts Operating No. Field Power Minimum Circuit l Maximum External Fuse j Field Power k Ground k Models and Phase Voltage Range Circuits Ampacity or Circuit Breaker Wire Size Wire Size W12 AAAA0Z m 1 9 15 14 14. A03 m 230/208-1 197-253 1 20 20 12 12. A05 m 1 27 30 10 10. W12 AAAK00 1 17 30 10 10. 115-1 104-126.

8 K02 1 26 30 10 10. Maximum size of the time delay fuse circuit breaker for protection of field wiring conductors. CAUTION! When more than one field power conductor Based on 75 C copper wire. All wiring must conform to NEC and all local codes. circuit is run through one conduit, the conductors must These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. be derated. Pay special attention to note 8 of table 310. Refer to the National Electrical Code (latest revision), article 310 for power conductor sizing.

9 Regarding Ampacity Adjustment Factors when more than 3. Internal circuit breakers are standard on W12 AAAA models. conductors are in a raceway. Specifications Electrical Compressor Outdoor Fan Motor Indoor Blower Motor CFM / ESP Shipping Models Rating - 60 Hz RLA LRA HP-RPM-SP FLA HP-RPM-SP FLA (Rated-WET Coil) Weight W12 AAAA 230/208-1 / 26 1/12-1075-1 .70 1/8-1650-1 .70 400/.20 185 lbs. W12 AAAK 115-1 57 1/12-1075-1 1/8-1650-1 400/.20 185 lbs. Electric Heat Table Indoor Blower Performance - CFM at 230 Volts Models W12 AAAA W12 AAAK High Speed in H2O Dry/Wet Coil 240V-1 208V-1 120V-1.

10 0 525/500. KW AMPS BTUH AMPS BTUH AMPS BTUH..1 475/450. 12,285 9,230 - - .2 425/400. 17,065 12,800 - - .3 375/360. - - - - 7,510 .4 315/300. Cooling Application Data - Outdoor Temperature F . Return Air Model (DB/WB) Cooling Capacity 75 F 80 F 85 F 90 F 95 F 100 F 105 F 110 F 115 F 120 F.. Total Cooling 14,100 13,100 12,200 11,300 10,500 9,800 9,100 8,500 7,900 7,400. 75/62. Sensible Cooling 10,900 10,400 9,900 9,500 9,200 8,800 8,500 8,100 7,700 7,300. Total Cooling 15,000 14,200 13,500 12,700 12,000 11,400 10,700 10,100 9,500 8,900.