Transcription of Three Phase Padmounted - ABB
1 Three Phase Padmounted Transformers45-3000 kVAABB3 Introduction to ABBABB is a global leader in power and automa-tion technologies that enable utility and indus-try customers to improve their performancewhile lowering their environmental TransformersABB Distribution Transformers provide themost complete line of Padmounted transform-ers to meet the applications of any distributionsystem. We are a dominant force in the indus-try. We lead the way with the introduction of new products and services for the ever-changing distribution transformer can offer cost-effective solutions for powerdistribution. We support our industry with acommitment to product development. We uti-lize the latest manufacturing technology tomaintain state-of-the-art quality and productiv-ity. Large vertical integration allows us to shiphigh quality products in the shortest possibleproduction cycle.
2 We are in alliances withmajor utilities and businesses around the worldproviding products and services to meet alltheir will continue to build on a heritage ofquality, customer satisfaction and technology,and capitalize on its resources, to maintain itsposition as the number one supplier of trans-formers in the Quality PolicyTotal customer satisfaction through continualprocess ValuesOur values guide us in how we go about meet-ing our vision and Success We seek to provide solu-tions for mutual competitive advantage. We setthe highest standards for quality, meet deliverycommitments and provide high Excellence We want to be recognizedas a company that exceeds our customers Quality StrategyStart with a focus on the what is a benchmark for highest standard for quality. Have a means to dramatically improve perfor-mance against the ABB MTR is an oil-filled, Three - Phase , commercialpadmounted distribution transformer specificallydesigned for servicing such underground distributionloads as shopping centers, schools, institutions andindustrial plants.
3 It is available in both live front and deadfront construction, for radial or loop feed applications,with or without MTR meets the following industry standards:IEEE TR1 ANSI Rev. 4 IEEE : 45 through 3000 kVA 65 C average winding rise 60 hertz standard, 50 hertz optional45-1500 kVA High voltages: 4160 Grd Y/2400 through 34,500 GrdY/19,920 for Grounded Wye systems; 2400 through34,500 for Delta systems; various dual high voltages2000-3000 kVA High voltages: 7200 Grd Y/4160 through 34,500 GrdY/19,920 for Grounded Wye systems; 4160 through34,500 for Delta systems; various dual high voltages Taps: All voltages are available with or without taps Insulation classes: 35 kV, 150 kV BIL and below45-1500 kVA Low voltages: 208Y/120, 216Y/125, 460Y/265, 480Y/277,480 , 240 and 240 with 120 volt mid-tap in onephase.
4 (4160Y/2400, 4160 , 2400 , 2400/4160Y/2400for 500 kVA and larger)2000-3000 kVA Low voltages: 460Y/265, 480Y/277, 480 , 4160Y/2400,2400 , 2400/4160Y/2400 Standard Features:1. Four lifting Bolted-on terminal compartment (18" or 24" deepdepending on KVA) with removable front sill. 3. Hinged, lift-off cabinet penta-head bolt/padlock handle operates acam assembly which is part of the 3-point door latchingmechanism. (A hex-head bolt is available.)5. For live front construction, externally clamped highvoltage porcelain bushings with a single eyebolt,clamp-type connector (accommodates #6 AWG solidto 250 MCM stranded conductors).6. For dead front construction, externally clamped highvoltage bushing wells for loadbreak or Lightning arrester mounting pads (live front only).8. Tank ground pads (1 in HV, 1 in LV).
5 9. Steel high/low voltage compartment One 1/2" penta-head bolt must be removed from theflange formed on the steel high/low barrier beforethe HV door can be opened (1/2" hex-head boltavailable as an option).11. Externally clamped low voltage bushings withthreaded copper stud for full load current below2100 amps. Externally clamped integral low voltagebushings for current above 2100 amps. NEMA spadesprovided per ANSI hole Fill plug and self-actuating pressure relief Drain neutral ground Five-legged core/coil cover bolted onto tank top (protected by weathercover).18. Panel-type NEMA safety paint finish process applies a durable, corrosionresistant finish to the product. The multi-step processincludes an epoxy primer uniformly applied bycationic electrodeposition and a urethane top Features:Primary Termination Externally-clamped bushing wells with loadbreak ornon-loadbreak inserts.
6 Integral loadbreak Termination Externally-clamped bushings with NEMA 6-hole, 8-hole, 10-hole, or 12-hole spades. Spade supports are available. They are provided for 8-hole spades and larger when the current is 1400amps or Switching LBOR oil switch: one for radial, two for loop feed. Externally-operated tap changer. Externally-operated dual voltage switch. Externally-operated delta-wye Protection Internal primary protective links. Bayonet-type expulsion fuses. Drawout, loadbreak current limiting fuses, with orwithout interlocking transformer switch. Secondary oil circuit breaker. Internal, partial-range current limiting Protection Distribution class, metal oxide arresters, 3-36 kV. Distribution class, valve-type lightning arresters, 3-27 Phase Padmounted TransformersABB5 Construction Options 18", 24" and 30" deep terminal cabinet.
7 Drain valve and sampling device. Mounting plate for CT s or PT s. Interphase barriers. Molded case external secondary breaker. Substation Accessories Oil gauge, thermometer, drainvalve and sampler, pressure-vacuum gauge provision. Weathercover. Transformers may feature an optional weathercoverover the cabinet which is hinged to allow clearancefor replacement of the bayonet-type fuses. The weathercover can be lifted easily into place andsecured with a single supporting arm. The weathercover requires no additional optional features are not available on larger kVA Front, Radial FeedANSI Fig. 1, 2, and 3 ( ) FactoryDead Front, Radial FeedIEEE Fig. 1, 3, and 4 ( ) FactoryDead Front, Loop FeedIEEE Fig. 2, 3, and 4 ( ) FactoryDesign Dimensions:Approximate weights and dimensions: Dimensions are ininches, weights are in pounds.
8 Dimensions may changeto meet the customer "ACDBMINIMUM CABLE OPENINGMAXIMUM PADDIMENSIONS76"70"42" "3" "Top ViewFront ViewSide View6 ABBWe offer a fliptop air enclosure for Three Phase padmountedtransformers. It is designed to improve operation and tobetter withstand its outdoor environment. New manufac-turing equipment has allowed ABB to fabricate a flip-top cabinet design to better serve the needs of ourcustomers. Material choices consist of both carbon steeland stainless improvementfeatures of the new cabinet designinclude: One piece sloped cabinet weather cabinet weathercover has a fourdegree sloped surfaceto shed all moisture tothe rear of the trans-former. Both the handholeweather cover and thefull tank weather coverhave a four degreesloped surface to shed water. The fulltank weather coveroption extends beyondthe rear of the transformer to insure all moisture isdirected away from the top of the tank.
9 The cabinet weather cover support arm is free floating and locks into place automatically. This allowsthe linemen to use both hands when raising the reaching into the compartment is necessary tosecure the cover in place. The cabinet weather cover can be rotated beyond centeror easily removed for better access into the the cabinetcompartment. The capability of pulling cables fromabove was a feature requested by utilities. The interface between the sidewalls and the cabinetweather cover has been redesigned to better receivethe weather cover when closed. This new interfaceminimizes surface contact to prevent the rubbing of paint. This cabinet design hassuccessfully passed allindustry tamper resis-tance Guidelines forTesting EnclosureIntegrity, the designpassed pry tests, pulltests, wire probe tests,deflection tests, and theoperation test.
10 The testsperformed confirm thatthe cabinet meets thetamper resistancerequirements of at both 0 and15 psig, as well as and demonstratingsufficient strength towithstand an internalstatic pressure of 7 psigwithout permanent distortion and 15 psig without rup-turing or displacing components of the transformer oraffecting cabinet Cabinet DesignSupport Arm Locking MechanismABB7 The Mini- Three Phase Padmounted Transformer (MTP) isdesigned for the needs of utility customers to reducecosts and improve aesthetics. The design is easier tohandle, install and maintain. The discreet profile of theMTP is ideal for commercial applications such as banks,stores and MTP features a hood and removable sill instead ofdoors. The design allows easy access for installation andmaintenance of the ABB MTP meets the following industry standards:IEEE TR-1 IEEE , Rev.