Timers GT3A - IDEC

Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers843800-262-IDEC (4332) USA & CanadaGT3 ATimersGT3 ASwitches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers843GT3A Series Analog TimersKey features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions Power and output status indicating LEDsUL, c-UL ListedFile No. E55996 SpecificationsGT3A-1GT3A-2GT3A-3GT3A-4,- 5,-6 OperationMulti-modeMulti-mode with inputs (11 pins)Time to 180 hoursRated Voltage100 to 240V AC, 50/60Hz12V DC24V AC, 50/60Hz / 24V DCContact Ratings 125V AC/250V AC, 3A; 30V DC, 1A (resistive load)125V AC/250V AC, 5A; 30V DC, 5A (resistive load)Minimum Applicable Load5V, 10mA (reference value)Voltage ToleranceAF20 (100V AC): 85 to 264V ACAD24: to to DCD12: to DCError , 10 msec (repeat, voltage, temperature)

Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 800-262-IDEC 4332 • SA Canada 845 Timers GT3A Timing Diagrams/Schematics

Tags:

  Breaker, Timer, Contactors, Timers gt3a, Gt3a

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Timers GT3A - IDEC

1 Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers843800-262-IDEC (4332) USA & CanadaGT3 ATimersGT3 ASwitches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers843GT3A Series Analog TimersKey features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions Power and output status indicating LEDsUL, c-UL ListedFile No. E55996 SpecificationsGT3A-1GT3A-2GT3A-3GT3A-4,- 5,-6 OperationMulti-modeMulti-mode with inputs (11 pins)Time to 180 hoursRated Voltage100 to 240V AC, 50/60Hz12V DC24V AC, 50/60Hz / 24V DCContact Ratings 125V AC/250V AC, 3A; 30V DC, 1A (resistive load)125V AC/250V AC, 5A.

2 30V DC, 5A (resistive load)Minimum Applicable Load5V, 10mA (reference value)Voltage ToleranceAF20 (100V AC): 85 to 264V ACAD24: to to DCD12: to DCError , 10 msec (repeat, voltage, temperature)Setting Error 10% maximumReset Time60msec maximumInsulation Resistance100MW minimumDielectric StrengthBetween power and output terminals: 2,000V AC, 1 minuteBetween contacts of different poles: 2,000V AC, 1 minuteBetween contacts of the same pole: 750V AC, 1 minutePower Consumption (approximate)Delayed SPDTD elayed SPDT + instantaneous SPDTD elayed DPDTD elayed (200V AC, 60Hz) (200V AC, 60Hz) (200V AC, 60Hz) (100V AC, 60Hz), (200V AC, 60Hz) 12 VDC/1W24 Life 10,000,000 operations minimum 5,000,000 operations minimumElectrical LIfe 50,000 operations minimum (rated load)100,000 operations minimum (rated load)Weight (approximate)63g73g79g80gVibration Resistance100m/sec2 (approximate 10G)Shock ResistanceOperating extremes: 100m/sec2 (approximate 10G)Damage limits.

3 500m/sec2 (approximate 50G)Operating Temperature 10 to +50 COperating Humidity45 to 85% RHStorage Temperature 30 to +80 CHousing ColorGraySwitches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit BreakersGT3 ATimers844 NumbersGT3A-1, -2, -3 Mode Of OperationRated Voltage CodeTime RangeOutputContactComplete Part 11-PinA: ON-delay 1B: Interval 1C: Cycle 1D: Cycle 3AF20: 100 to 240V AC (50/60Hz) seconds to 180 hours 250V AC, 3A,30V DC, 1A(resistive load)Delayed SPDTGT3A-1AF20GT3A-1 EAF20AF20: 100 to 240V AC (50/60Hz)D12: 12V DCAD24: 24V AC (50/60Hz)/24V DCDelayed SPDT +Instantaneous SPDTGT3A-2AF20GT3A-2 EAF20GT3A-2D12GT3A-2ED12GT3A-2AD24GT3A-2 EAD24240V AC, 5A,24V DC, 5A(resistive load)Delayed DPDTGT3A-3AF20GT3A-3 EAF20GT3A-3D12GT3A-3ED12GT3A-3AD24GT3A-3 EAD24 1.

4 For wiring schematics and timing diagrams for gt3a -1, -2, -3, see pages page 845 and page 846 For more details about time ranges, see instructions on page page For socket and accessory part numbers, see page , -5, -6 Mode of OperationRated Voltage CodeTime RangeOutputContactInputComplete Part (11-pin)B (11-pin)A: ON-Delay 2B: Cycle 2C: Signal ON/OFF-Delay 1D: Signal OFF-Delay 1AF20: 100 to 240V AC (50/60Hz)D12: 12V DCAD24: 24V AC (50/60Hz)/24V secondsto 180 hours250V AC, 5A,24V DC, 5A(resistive load)Delayed DPDTS tartResetGateGT3A-4AF20GT3A-4 EAF20GT3A-4D12GT3A-4ED12GT3A-4AD24GT3A-4 EAD24A: Interval 2B: One-Shot CycleC: Signal ON/OFF-Delay 2D: Signal OFF-Delay 2AF20: 100 to 240V AC (50/60Hz)AD24: 24V AC (50/60Hz)/24V DCGT3A-5AF20GT3A-5 EAF20GT3A-5AD24GT3A-5 EAD24A: One-ShotB: One-Shot ON-DelayC: One-Shot 2D: Signal ON/OFF-Delay 3GT3A-6AF20GT3A-6 EAF20GT3A-6AD24GT3A-6 EAD24 4.

5 For wiring schematics and timing diagrams gt3a -4,-5,-6, see pages 832, 833, and 833 For more details about time ranges, see instructions on page A (11-pin) and B (11-pin) differ in the way inputs are For socket and accessory part numbers, see page For the timing diagrams overview, see page & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers845800-262-IDEC (4332) USA & CanadaGT3 ATimersTiming Diagrams/SchematicsGT3A-1 Timing DiagramsDelayed SPDTO peration Mode SelectionON-Delay 1 AMODEItemTerminal NumberOperationSet TimeTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact5 - 8 (8p)8 - 11 (11p)(NC)6 - 8 (8p)9 - 11 (11p)(NO)IndicatorPOWEROUTI nterval 1 BMODEItemTerminal NumberOperationSet TimeTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact5 - 8 (8p)8 - 11 (11p)(NC)6 - 8 (8p)9 - 11 (11p)(NO)IndicatorPOWEROUTC ycle 1(OFF first) CMODEItemTerminal NumberOperationSet TimeTTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact5 - 8 (8p)8 - 11 (11p)(NC)6 - 8 (8p)9 - 11 (11p)(NO)IndicatorPOWEROUTC ycle 3(ON first) DMODEItemTerminal NumberOperationSet TimeTTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact5 - 8 (8p)8 - 11 (11p)(NC)6 - 8 (8p)9 - 11 (11p)(NO)

6 IndicatorPOWEROUTS witches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit BreakersGT3 ATimers846 Timing DiagramsDelayed SPDT + Instantaneous SPDTO peration Mode SelectionON-Delay 1 AMODEItemTerminal NumberOperationSet TimeTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact5 - 8 (8p)8 - 11 (11p)(NC)6 - 8 (8p)9 - 11 (11p)(NO)Instantaneous Contact1 - 4(NC)1 - 3(NO)IndicatorPOWEROUTI nterval 1 BMODEItemTerminal NumberOperationSet TimeTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact5 - 8 (8p)8 - 11 (11p)(NC)6 - 8 (8p)9 - 11 (11p)(NO)Instantaneous Contact1 - 4(NC)1 - 3(NO)IndicatorPOWEROUTC ycle 1(OFF first) CMODEItemTerminal NumberOperationSet TimeTTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact5 - 8 (8p)8 - 11 (11p)(NC)6 - 8 (8p)9 - 11 (11p)(NO)Instantaneous Contact1 - 4(NC)1 - 3(NO)IndicatorPOWEROUTC ycle 3(ON first) DMODEItemTerminal NumberOperationSet TimeTTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact5 - 8 (8p)8 - 11 (11p)(NC)6 - 8 (8p)9 - 11 (11p)(NO)Instantaneous Contact1 - 4(NC)1 - 3(NO)IndicatorPOWEROUTGT3A-3 Timing DiagramsDelayed DPDTO peration Mode SelectionON-Delay 1 AMODEItemTerminal NumberOperationSet TimeTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact1 -4, 5 - 8 (8p)1 -4, 8 - 11 (11p)(NC)1 -3, 6 - 8 (8p)1 -3, 9 - 11 (11p)(NO)

7 IndicatorPOWEROUTI nterval 1 BMODEItemTerminal NumberOperationSet TimeTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact1 -4, 5 - 8 (8p)1 -4, 8 - 11 (11p)(NC)1 -3, 6 - 8 (8p)1 -3, 9 - 11 (11p)(NO)IndicatorPOWEROUTC ycle 1(OFF first) CMODEItemTerminal NumberOperationSet TimeTTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact1 -4, 5 - 8 (8p)1 -4, 8 - 11 (11p)(NC)1 -3, 6 - 8 (8p)1 -3, 9 - 11 (11p)(NO)IndicatorPOWEROUTC ycle 3(ON first) DMODEItemTerminal NumberOperationSet TimeTTPower2 - 7 (8p)2 - 10 (11p)Delayed Contact1 -4, 5 - 8 (8p)1 -4, 8 - 11 (11p)(NC)1 -3, 6 - 8 (8p)1 -3, 9 - 11 (11p)(NO)IndicatorPOWEROUTNote: Pins 1, 3, and 4 are the instantaneous & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers847800-262-IDEC (4332) USA & CanadaGT3 ATimersGT3A-4 Timing DiagramsDelayed DPDTO peration Mode SelectionON-Delay 2 AMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)ON or LGate2 - 5 (A) ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)IndicatorPOWEROUTSet TimeTTaT'T"Cycle 2 BMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)ON or LGate2 - 5 (A) ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)

8 IndicatorPOWEROUTSet TimeTTTTTTTTaTTTT"T"TTTTTS ignal ON/OFF-Delay 1 CMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)ON or LGate2 - 5 (A) ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)IndicatorPOWEROUTSet TimeTTTaTTaTTTT"TaSignal OFF-Delay 1 DMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)ON or LGate2 - 5 (A) ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)IndicatorPOWEROUTSet TimeTTaTaTTT T = Set time Ta = Shorter than set timeT = T' + T"Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit BreakersGT3 ATimers848 Timing DiagramsDelayed DPDTO peration Mode SelectionInterval 2 AMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)ON or LGate2 - 5 (A) ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)IndicatorPOWEROUTSet TimeTTaT'T"One-Shot Cycle BMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)ON or LGate2 - 5 (A)

9 ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)IndicatorPOWEROUTSet TimeTTTTaT'T"TSignal ON/OFF-Delay 2 CMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)ON or LGate2 - 5 (A) ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)IndicatorPOWEROUTSet TimeTTTaTTaTaTT'T"TaSignal OFF-Delay 2 DMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)ON or LGate2 - 5 (A) ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)IndicatorPOWEROUTSet TimeTTaTaTT'T" T = Set time Ta = Shorter than set timeT = T' + T"Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers849800-262-IDEC (4332) USA & CanadaGT3 ATimersGT3A-6 Timing DiagramsDelayed DPDTO peration Mode SelectionOne-Shot 1 AMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)ON or LGate2 - 5 (A) ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)IndicatorPOWEROUTSet TimeTaTaTTaT'T"One-Shot ON-Delay BMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)

10 ON or LGate2 - 5 (A) ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)IndicatorPOWEROUTSet TimeTTTaTTT'T"One-Shot 2 CMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2 - 6 (A)5 - 7 (B)ON or LReset2 - 7 (A)6 - 7 (B)ON or LGate2 - 5 (A) ON or LDelayed Contact1 - 48 - 11(NC)1 - 39 - 11(NO)IndicatorPOWEROUTSet TimeTTaTT'T"Signal ON/OFF-Delay 3 DMODEItemTerminal NumberOperationPower2 - 10 POWERI nputStart2