Example: dental hygienist

TM 5-809-3 Masonry Structural Design for Buildings

ARMY TM 5-809-3 NAVY NAVFAC FORCE AFM 88-3, Chap. 3 MASONRYSTRUCTURAL DESIGNFOR BUILDINGSAPPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITEDDEPARTMENTS OF THE ARMY, THE NAVY, AND THE AIR FORCEOCTOBER 1992 REPRODUCTION AUTHORIZATION/RESTRICTIONSThis manual has been prepared by or for the Government and, except to the extent indicatedbelow, is public property and not subject to material included in the manual has been used with the knowledge andpermission of the proprietors and is acknowledged as such at point of use. Anyone wishing to makefurther use of any copyrighted material, by itself and apart from this text, should seek necessarypermission directly from the or republications of this manual should include a credit substantially as follows: Joint Departments of the Army, Navy, and Air Force, TM 5-809-3 /NAVFAC 88-3,Chap.

5-2. Equivalent Wall Thickness for Computing Compression and Shear Stress Parallel to the Wall for Hollow Concrete Masonry Units, Inches. 5-3. Area Effective in Axial Compression and in In-Plane Shear, A e, in2/ft. 5-4. Gross Moment of Inertia and Cracking Moment Strength for Various Widths of CMU Walls. Type S Mortar, f' m = 1350. 5-5.

Tags:

  Design, Building, Walls, Shares, Structural, Concrete, Masonry, Masonry structural design for buildings

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TM 5-809-3 Masonry Structural Design for Buildings

1 ARMY TM 5-809-3 NAVY NAVFAC FORCE AFM 88-3, Chap. 3 MASONRYSTRUCTURAL DESIGNFOR BUILDINGSAPPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITEDDEPARTMENTS OF THE ARMY, THE NAVY, AND THE AIR FORCEOCTOBER 1992 REPRODUCTION AUTHORIZATION/RESTRICTIONSThis manual has been prepared by or for the Government and, except to the extent indicatedbelow, is public property and not subject to material included in the manual has been used with the knowledge andpermission of the proprietors and is acknowledged as such at point of use. Anyone wishing to makefurther use of any copyrighted material, by itself and apart from this text, should seek necessarypermission directly from the or republications of this manual should include a credit substantially as follows: Joint Departments of the Army, Navy, and Air Force, TM 5-809-3 /NAVFAC 88-3,Chap.

2 3, Masonry Structural Design for the reprint or republication includes copyrighted material, the credit should also state: Anyone wishing to make further use of copyrighted material, by itself and apart from this text,should seek necessary permission directly from the proprietor. i*TM 5-809-3 *NAVFAC *AFM 88-3, Chap. 3 TECHNICAL MANUAL HEADQUARTERSNO. 5-809-3 DEPARTMENT OF THE ARMYNAVY MANUAL THE NAVY, AND THE AIR FORCENAVFAC FORCE MANUALNO.

3 88-3, CHAPTER 3 WASHINGTON, DC, 30 October 1992 Masonry Structural Design FOR BUILDINGSP aragraph PageCHAPTER 1. 1-1 1-2 1-3 1-12. QUALITY ASSURANCE IN 2-1 2-1 Design /Construction Process 2-2 2-1 Role of Design 2-3 2-13. MATERIALS, PROPERTIES, STANDARD TESTS AND 3-1 3-1 Clay Masonry 3-2 3-1 concrete Masonry 3-3 3-4 3-5 3-6 3-7 Standard 3-7 3-8 3-84.

4 Design FOR CRACK 4-1 4-1 concrete Masonry 4-2 4-1 Brick 4-3 4-2 Anchored 4-4 4-3 Composite 4-5 4-3 Isolation of Nonstructural 4-6 4-3 Shelf 4-7 4-3 Other Than Running Bond 4-8 435. GENERAL CRITERIA FOR REINFORCED 5-1 5-1 Working Stress 5-2 5-1 Structural 5-3 5-1 Working Stress Design 5-4 5-5 Allowable Working 5-5 5-8 Basic Reinforcement 5-6 5-10 Connections Between 5-7 5-116.

5 REINFORCED Masonry 6-1 6-1 Design 6-2 6-1 Structural 6-3 6-1 Wall Design 6-4 6-1P-Delta 6-5 6-4 walls With 6-6 6-4 Design 6-7 6-4 Design 6-5 6-47. REINFORCED Masonry SHEAR 7-1 7-2 7-1 Allowable Shear 7-3 7-1 Design 7-4 7-5 7-3 Distribution of Forces to Shear 7-6 7-4 Effects of Openings in Shear 7-7 7-4_____*This manual supersedes TM 5-809-3 /NAVFAC 88-3, Chapter 3 dated August 1982TM 5-809-3 /NAVFAC 88-3, Chap.

6 3iiParagraph PageShear Wall Rigidity 7-5 7-6 Design 7-9 7-8 CHAPTER 8. 8-1 8-2 8-1 Allowable 8-3 8-1 Masonry Lintel 8-4 8-1 Bearing Pressure at Lintel 8-5 8-2 Lateral 8-6 8-3 Design 8-7 8-3 Design 8-8 8-39. COLUMNS AND 9-1 9-1 Minimum 9-2 9-3 9-2 General 9-4 9-4 Design 9-5 9-5 Design 9-6 9-810. NONDESTRUCTIVE EVALUATION 10-1 10-2 10-1 NDE 10-3 10-1 Applications of Combined 10-4 10-1 NDE 10-5 10-1 Advantages and Disadvantages of all NDE 10-6 10-11 APPENDIX A: REFERENCES A-lB: Design AIDS FOR REINFORCED Masonry walls B-lC.

7 LINTEL Design AIDS C-lBIBLIOGRAPHY Bibliography 1 LIST OF FIGURESF igure 3-1. Typical Clay Masonry Examples of concrete Masonry Strength of Mortar PSI Versus Constituent Masonry Wall Masonry Stress-Strain Open-End Unit 8 in X 8 in X 16 Assumed Dimensions and Effective Areas of Hollow Working Stress Flexural Design Assumptions for Rectangular Working Stress Flexural Design Assumptions for Effective Embedment, 1 and edge distance, 1b be6-1.

8 Wall Loading, Moment and Deflection Diagrams-Wind and Axial load Moments Wall Loading, Moment and Deflection Diagrams-Wind and Axial load Moments not Example 3 Wall Section A through Wall M/Vd Ratios for Shear Shear Wall Deformation of Shear Wall With Relative Rigidities of Piers and Wall Deflection Wall Deflection Design Example 1 Wall Design Example 2 Wall Triangular and Concentrated Loading on Example 1 Wall Example 1 Lintel Cross Example 2 Wall Example 2 Lintel Cross Example 3 Wall Example 3 Lintel Cross Dead Load Shear and Moment Live Load Shear and Moment Location of Web Reinforcing in Isolated concrete Masonry concrete

9 Masonry Pilaster with Continuous Bond Uncracked 5-809-3 /NAVFAC 88-3, Chap. 3iiiLIST OF FIGURES (Cont**d) Locations of Beams and Carrying Capacities of Columns vs. Compressive Strength vs. Rebound Deformations Around Flatjack Slot During In-Situ Stress Curve Obtained During In-Situ Deformability For Modified In-Plane Shear Ultrasonic Test Dimensional Surface Representing Through-wall Ultrasonic Pulse Arrival Pulse Testing Path Length vs. Arrival OF Control Joint Spacing and Spacing of Vertical Expansion Joints in Brick walls , ) T = Dimensions of Hollow concrete Masonry Units and Associated Dimensions, Wall Thickness for Computing Compression and Shear Stress Parallel to the Wall for Hollow concrete Masonry Units, Effective in Axial Compression and in In-Plane Shear, A, Moment of Inertia and Cracking Moment Strength for Various Widths of CMU walls .

10 Type S Mortar, f' = of CMU walls , w, Pounds Per Square Areas, Net Areas and Average Weights of concrete Masonry Working Stresses in Reinforced Working Stresses for Grade 60 Reinforcing Reinforcing Steel Ratio Along With k and j for Fully Grouted CMU in Running =60,000 Reinforcing Steel, One Bar Per Cell, Fully Grouted CMU walls in Running Bond. f 1350 psi, f =60,000 psi.'m Reinforcing Steel, Two Bars Per Cell, Fully Grouted CMU walls . f' = 1350 psi, f = 60,000 Tension in Bolts, Ba, in Pounds, Based on the Compressive Strength of Tension in Bolts, Ba, in Pounds, Based on a Steel Yield Strength of 36,000 Shear, B, in Pounds, Based On the Listed Values of f* and a Steel Yield Strength of 36,000 and Moment of Inertia of Net Wall factors for Columns and of NDE of Wall Stiffeners With One Reinforcing Bar in Each Reinforced Cell, 6 in CMU, Type S of Wall Stiffeners With One Reinforcing Bar in Each Reinforced Cell, 8 in CMU, Type S of Wall Stiffeners With One Reinforcing Bar in Each Reinforced Cell, 10 in CMU, Type S of Wall Stiffeners With One Reinforcing Bar in Each Reinforced Cell, 12 in CMU.