Example: air traffic controller

Tracer® UC600 Programmable Controller - Trane Index

SSAAFFEETTYY ,startingup,andservicingofheating,ventil ating, , ,observeallprecautionsintheliteratureand onthetags,stickers, ,Operation,andMaintenanceTracer UC600 ProgrammableControllerOrderingNumber:BMU C600 AAA0100011 2020 TraneBAS-SVX45J-ENIntroductionTheTracerU C600controlleris a multi-purpose, Programmable , isdesignedtocontrolthefollowingtypesofeq uipment: Air-handlingunits(AHUs) Rooftopunits Chillers Centralheatingandcoolingplants Coolingtowers Genericinput/output(I/O)controlWarnings, Cautions,and types ofadvisoriesare definedas follows:WARNINGI ndicatesa potentiallyhazardoussituationwhich,if notavoided,could result indeath potentiallyhazardoussituationwhich,if notavoided,could result inminor or moderate injury. It could also beused to situationthat could resultin equipmentor property-damage FFiieelldd WWiirriinngg aanndd GGrroouunnddiinngg RReeqquuiirreedd!!FFaaiilluurree ttoo ffoollllooww ccooddee ccoouulldd rreessuulltt iinn ddeeaatthh oorr sseerriioouuss ffiieelldd wwiirriinngg MMUUSSTT bbee ppeerrffoorrmmeedd bbyy qquuaalliiffiieedd IImmpprrooppeerrllyy iinnssttaalllleedd aannddggrroouunnddeedd ffiieelldd wwiirriinngg ppoosseess FFIIRREE aanndd EELLEECCTTRROOCCUUTTIIOONN TToo aavvooiidd tthheessee hhaazzaarrddss,,yyoouu MMUUSSTT ffoollllooww rreeqquuiirreemmeennttss ffoorr ffiieelldd wwiirriinngg iinnssttaallllaattiioonn aanndd ggrroouunnddiinngg aass ddeessccrriibbeedd iinnNNEECC aanndd yyoouurr llooccaall//ssttaattee//nnaat

©2020 Trane BAS-SVX45J-EN Introduction The Tracer UC600 controller is a multi-purpose, programmable, wireless-compatible device. It is designed to control the …

Tags:

  Controller, Trane, Programmable, Uc600 programmable controller, Uc600

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Tracer® UC600 Programmable Controller - Trane Index

1 SSAAFFEETTYY ,startingup,andservicingofheating,ventil ating, , ,observeallprecautionsintheliteratureand onthetags,stickers, ,Operation,andMaintenanceTracer UC600 ProgrammableControllerOrderingNumber:BMU C600 AAA0100011 2020 TraneBAS-SVX45J-ENIntroductionTheTracerU C600controlleris a multi-purpose, Programmable , isdesignedtocontrolthefollowingtypesofeq uipment: Air-handlingunits(AHUs) Rooftopunits Chillers Centralheatingandcoolingplants Coolingtowers Genericinput/output(I/O)controlWarnings, Cautions,and types ofadvisoriesare definedas follows:WARNINGI ndicatesa potentiallyhazardoussituationwhich,if notavoided,could result indeath potentiallyhazardoussituationwhich,if notavoided,could result inminor or moderate injury. It could also beused to situationthat could resultin equipmentor property-damage FFiieelldd WWiirriinngg aanndd GGrroouunnddiinngg RReeqquuiirreedd!!FFaaiilluurree ttoo ffoollllooww ccooddee ccoouulldd rreessuulltt iinn ddeeaatthh oorr sseerriioouuss ffiieelldd wwiirriinngg MMUUSSTT bbee ppeerrffoorrmmeedd bbyy qquuaalliiffiieedd IImmpprrooppeerrllyy iinnssttaalllleedd aannddggrroouunnddeedd ffiieelldd wwiirriinngg ppoosseess FFIIRREE aanndd EELLEECCTTRROOCCUUTTIIOONN TToo aavvooiidd tthheessee hhaazzaarrddss,,yyoouu MMUUSSTT ffoollllooww rreeqquuiirreemmeennttss ffoorr ffiieelldd wwiirriinngg iinnssttaallllaattiioonn aanndd ggrroouunnddiinngg aass ddeessccrriibbeedd iinnNNEECC aanndd yyoouurr llooccaall//ssttaattee//nnaattiioonnaall eelleeccttrriiccaall PPrrootteeccttiivvee EEqquuiippmmeenntt ((PPPPEE)) RReeqquuiirreedd!

2 !FFaaiilluurree ttoo wweeaarr pprrooppeerr PPPPEE ffoorr tthhee jjoobb bbeeiinngg uunnddeerrttaakkeenn ccoouulldd rreessuulltt iinn ddeeaatthh oorr ,, iinn oorrddeerr ttoo pprrootteecctt tthheemmsseellvveess ffrroommppootteennttiiaall eelleeccttrriiccaall,, mmeecchhaanniiccaall,, aannddcchheemmiiccaall hhaazzaarrddss,, MMUUSSTT ffoollllooww pprreeccaauuttiioonnss iinn tthhiiss mmaannuuaall aanndd oonn tthhee ttaaggss,, ssttiicckkeerrss,, aannddllaabbeellss,, aass wweellll aass tthhee iinnssttrruuccttiioonnss bbeellooww:: BBeeffoorree iinnssttaalllliinngg//sseerrvviicciinngg tthhiiss uunniitt,, tteecchhnniicciiaannss MMUUSSTT ppuutt oonn aallll PPPPEE rreeqquuiirreedd ffoorrtthhee wwoorrkk bbeeiinngg uunnddeerrttaakkeenn ((EExxaammpplleess;; ccuutt rreessiissttaanntt gglloovveess//sslleeeevveess,, bbuuttyyll gglloovveess,,ssaaffeettyy ggllaasssseess,, hhaarrdd hhaatt//bbuummpp ccaapp,, ffaallll pprrootteeccttiioonn,, eelleeccttrriiccaall PPPPEE aanndd aarrcc ffllaasshhccllootthhiinngg)).

3 AALLWWAAYYSS rreeffeerr ttoo aapppprroopprriiaattee SSaaffeettyy DDaattaa SShheeeettss ((SSDDSS)) aanndd OOSSHHAA gguuiiddeelliinneess ffoorr pprrooppeerr WWhheenn wwoorrkkiinngg wwiitthh oorr aarroouunndd hhaazzaarrddoouuss cchheemmiiccaallss,, AALLWWAAYYSS rreeffeerr ttoo tthheeaapppprroopprriiaattee SSDDSS aanndd OOSSHHAA//GGHHSS ((GGlloobbaall HHaarrmmoonniizzeedd SSyysstteemmooff CCllaassssiiffiiccaattiioonn aannddLLaabbeelllliinngg ooff CChheemmiiccaallss)) gguuiiddeelliinneess ffoorr iinnffoorrmmaattiioonn oonn aalllloowwaabbllee ppeerrssoonnaall eexxppoossuurreelleevveellss,, pprrooppeerr rreessppiirraattoorryy pprrootteeccttiioonn aanndd hhaannddlliinngg IIff tthheerree iiss aa rriisskk ooff eenneerrggiizzeedd eelleeccttrriiccaall ccoonnttaacctt,, aarrcc,, oorr ffllaasshh,, tteecchhnniicciiaannss MMUUSSTT ppuuttoonn aallll PPPPEE iinn aaccccoorrddaannccee wwiitthh OOSSHHAA,, NNFFPPAA 7700EE,, oorr ootthheerr ccoouunnttrryy--ssppeecciiffiiccrreeqquu iirreemmeennttss ffoorr aarrcc ffllaasshh pprrootteeccttiioonn,, PPRRIIOORR ttoo sseerrvviicciinngg tthhee NNEEVVEERR PPEERRFFOORRMMAANNYY SSWWIITTCCHHIINNGG,, DDIISSCCOONNNNEECCTTIINNGG,, OORR VVOOLLTTAAGGEE TTEESSTTIINNGG WWIITTHHOOUUTT PPRROOPPEERREELLEECCTTRRIICCAALL PPPPEE AANNDD AARRCC FFLLAASSHH EENNSSUURREE EELLEECCTTRRIICCAALL MMEETTEERRSS AANNDDEEQQUUIIPPMMEENNTT AARREE PPRROOPPEERRLLYY RRAATTEEDD FFOORR IINNTTEENNDDEEDD EEHHSS PPoolliicciieess!

4 !FFaaiilluurree ttoo ffoollllooww iinnssttrruuccttiioonnss bbeellooww ccoouulldd rreessuulltt iinn ddeeaatthh oorr sseerriioouuss AAllll TTrraannee ppeerrssoonnnneell mmuusstt ffoollllooww tthhee ccoommppaannyy ss EEnnvviirroonnmmeennttaall,, HHeeaalltthh aanndd SSaaffeettyy((EEHHSS)) ppoolliicciieess wwhheenn ppeerrffoorrmmiinngg wwoorrkk ssuucchh aass hhoott wwoorrkk,, eelleeccttrriiccaall,, ffaallll pprrootteeccttiioonn,,lloocckkoouutt//tt aaggoouutt,, rreeffrriiggeerraanntt hhaannddlliinngg,, WWhheerree llooccaall rreegguullaattiioonnss aarree mmoorreessttrriinnggeenntt tthhaann tthheessee ppoolliicciieess,, tthhoossee rreegguullaattiioonnss ssuuppeerrsseeddee tthheessee NNoonn--TTrraannee ppeerrssoonnnneell sshhoouulldd aallwwaayyss ffoollllooww llooccaall arethepropertyofTrane, , AddedrevisedscreeshottoConnectingUsingTr acerSC/SC+section. AddedadditionaldetailstoUsingPre-package dSolutions(PPS)section. RevisedCurrentInputMethod1 inCommissioningandTroubleshootingina PoweredStatesection.

5 AddedSettingUpUC600 BACnetCommunicationtoConfiguringTracerUC 600 .. 7 SmokeControlSupport(UUKL).. 7 Air-Fi WirelessCommunicationsInterface(WCI)Supp ort.. 7 ExpansionModuleRequirements.. 7 Specifications.. 7 LocationofLEDs.. 8 HardwareTerminations.. 8 AdditionalOrderingOptions.. 9 RequiredToolsforMountingandWiring.. 10 Dimensions.. 10 InstallingtheTracerUC600 ProgrammableController.. 11 MountingandRemovingTracerDevices.. 11 SettingAddressesUsingRotarySwitches.. 12 SettingtheBACnetDeviceID .. 12 DeviceIDAssignmentforBACnetMS/TPDevices. . 13 DeviceIDAssignmentforBACnet/IPDevices.. 13 DeviceIDAssignmentforWirelessDevices.. 14 RotaryDialAddressSettingsforNon-TraneFro nt-endSystems.. 14 TracerUC600 Pre-powerChecks.. 15 ResistiveInputs.. 15 VoltageInputs.. 15 CurrentInputs.. 16 BinaryInputs.. 16 PowerBudgetCheckinanUn-poweredState.. 18 CalculatingACPowerConsumption.. 18 CalculatingDCPowerConsumption.. 18 WiringandPoweringtheTracerUC600.. 20 WiringRequirements.. 20 TransformerRequirements.

6 20 TugTestforTerminalConnectors.. 21 WiringACPowertoTracerUC600.. 21UC600 StartupandPowerCheck.. 22 BACnetMS/TPLinkWiring.. 23 BACnet/IPWiring.. 23 WiringInputsandOutputs.. 24 ProvidingLow-voltagePowerforInputs/Outpu ts.. 24 InputandOutputWiring.. 25 Tableof ContentsBAS-SVX45J-EN5 WiringUniversalInputs.. 25 WiringBinaryInputs.. 25 Wiring0 10 VdcAnalogInputs.. 26 Wiring0 20mAAnalogInputs.. 27 WiringVariableResistanceAnalogInputs.. 28 WiringTraneZoneSensors.. 29 WiringAnalogOutputsandPulseWidthModulati ngOutputs.. 30 WiringBinaryOutputs.. 31 ConnectingPressureTransducerInputs.. 32 TracerUC600 Operation.. 34 LEDD escriptionsandActivities.. 34 Troubleshooting.. 34 CommunicationProblems.. 34 OutputPoints.. 35 ConnectionProblems.. 35 ConfiguringTracerUC600withTracerTU.. 36 Startinga SessionofTracerTU.. 36 ConnectingUsingTracerSCorTracerSC+.. 38 UpgradingFirmware.. 38 ConfiguringTracerUC600andCreatingorEditi ngPoints.. 39 ConfiguringTracerUC600.. 39 UsingPre-packagedSolutions(PPS).

7 40 CreatingorEditingPointsfortheUC600.. 40 PlacingPointsinOut-of-ServiceMode.. 42 CreatingPointstoMonitorCommunicationandT GP2 Programs.. 42 CreatingPointsforTimedOverride(TOV)and*/ **Functions.. 43 MonitoringandViewingStatus.. 44 Backup.. 44 TransferFiles(Restore).. 45 SettingUpandMaintainingSchedules.. 45 Creatinga WeeklySchedule.. 45 ChangingtheScheduleDefaultValue.. 47 AddingExceptions.. 47 ModifyingExceptions.. 49 DeletingEvents.. 50 DeletingExceptions.. 50 Deletinga Schedule.. 51 CustomGraphics.. 51 GraphicsBestPractices.. 53 CommissioningandTroubleshootingina .. 54 TTaabbllee ooff CCoonntteennttss6 BAS-SVX45J-ENResistiveInputs.. 54 VoltageInputs.. 55 CurrentInputs.. 55 Method1 .. 55 Method2 .. 5624 VacMeasurement.. 57 BinaryInputs:24 VacDetect(Methods1 or2).. 58 BinaryInputs:BasedonAnalogOutputConnecti on.. 58 Open-collectorBasedBinarySensors.. 59 VoltageAnalogOutput.. 59 CurrentAnalogOutput(Methods1 or2).. 60 GroundMeasurements.. 61 Resources.. 62 AppendixA:ConfiguringTracerUC600forBACne t/IP.

8 63 DeviceIDAssignmentforBACnet/IPDevices.. 63 EthernetNetworkWiringSpecifications.. 63 BACnet/IPNetworkConfigurationonTracerSCo rTracerSC+.. 63 EnablingBBMDF unctionalityontheIPNetwork.. 63 SettingUpTracerUC600 BACnetCommunicationwithTracerTU.. 64 Establishinga DirectConnectionwithTracerTU.. 64 Establishinga NetworkConnectionwithTracerTU.. 65 ConfiguringIPInformation.. 66 ConfiguringBACnetInformation.. 67 SettingUpa BDT.. 68 Security.. 69 LocalNetwork(Firewall)Security.. 69 DisableHTTPC ommunications.. 69 DisableTracerUC600 UserInterface(TD7).. 69 TTaabbllee ooff CCoonntteennttssBAS-SVX45J-EN7 ProductOverviewThissectiondescribesthepr oductfeatures,specifications, (UUKL)TheTracerUC600programmablecontroll eris nowUL864certified,makingit fullycapableofservingasa componentofa ,seethe EngineeredSmokeControlSystemApplications Guide (BAS-APG019).Air-Fi WirelessCommunicationsInterface(WCI)Supp ortTheAir-Fi WirelessCommunicationsInterface(WCI)is analternativetoBACnet a wirelesscommunicationscomponent(option)a ddedtoTracercontrollersandis : Air-Fi WirelessCommunicationsInterfaceInstallat ionInstructions(X39641264001) Air-Fi WirelessInstallation,Operation,and Maintenance(BAS-SVX40) Air-Fi WirelessNetworkDesignBest PracticesGuide(BAS-SVX55)ExpansionModule RequirementsIf additionalinputoroutputpointsareneeded,t heXM30,XM32,XM70, TracerExpansionModuleIOM, (BAS-SVX46), SpecificationsStorageTemperature:-67 F to 203 F(-55 Cto 95 C)Relativehumidity:Between5% to 95%(non-condensing)OperatingTemperature: -40 F to 158 F(-40 Cto 70 C)Humidity:Between5% to 95%(non-condensing)Power: (24 Vac, 15%nominal)50 or 60 Hz, 26 VA(26 VA plus a maximumof 12 VA for each binaryoutput)Output:24 Vdc, 10%,devicemax load 600 mATime Clock:On-boardreal time clock with 7 day lb.

9 ( kg)Environmentalrating(enclosure):NEMA 1 Installation:UL 840: Category3 Pollution:UL 840: Degree28 BAS-SVX45J-ENLocationof LEDsLightemittingdiodes(LEDs) ,refertotheBACnetBest Practicesand TroubleshootingGuide(BAS-SVX51).Figure1. TracerUC600 LEDsSERVICE TOOLSERVICELINKACTIMCMBUSLINKRXTXUC600 ADDRESS0123456789x10123456789x1001234567 89x100BO4BO3BO2BO1 Binary output status LEDsEthernet LEDsCommunication status(Link, MBUS, IMC)Power LEDS ervice button and LEDH ardwareTerminationsTracerUC600supportsth efollowinghardwareterminations: Temperaturesensors(resistiveandthermisto r) Linearinputs0 20mA,suchashumiditysensors Linearinputs0 10 Vdc,suchasindoorair-qualitysensors Linearoutputs0-20mA,suchasvariablefreque ncydrives Linearoutputs0 10 Vdc,suchasactuatorsfordampersandvalves Pulseoutputs,suchaselectricheatorhumidif iercontrol Binaryoutputs,suchasfanstart/stop One3-wirepressuretransducerinput PulseaccumulatorTable2. TracerUC600deviceconnectionsInput/Output typeQuantityTypesRangeNotesUniversalinpu t8 Thermistor10k Type II, 10k TypeIII,2252 Type II, 20k Type IV, 100 k Resistive(Setpoint)100 1M RTDB alco (Ni-Fe),1k ; 375 (Pt),385 (Pt), 1k Current0 20mA (linear)Voltage0 20 Vdc (linear)BinaryDrycontactPulse accumulatorMinimum20 ms, openedorclosedUniversalInput/AnalogOutpu tConfigureusing any combinationof analogor binaryinputs/analogoutputsPPrroodduucctt OOvveerrvviieewwBAS-SVX45J-EN9 Table2.

10 TracerUC600deviceconnections(continued)I nput/OutputtypeQuantityTypesRangeNotes6 Thermistor10k Type II, 10k TypeIII,2252 Type II, 20k Type IV, 100 k The UC600provides600 mA of DC powerfor 0 20mA inputsand/oroutputs, (setpoint)100 1M RTDB alco (Ni-Fe),1k ; 375 (Pt),385 (Pt), 1k Current0 20mA (linear)Voltage0 20 Vdc (linear)BinaryDrycontactPulse accumulatorMinimum20 ms, openedorclosedOutputsCurrent0 20mA @16 VVoltage0 10 Vdc @20 1 second( ),1 secondto 60seconds( secondresolution)Binaryoutput4 Relay (formA) wet24 Vac, maximumRangesare given per 5 suppliedwith 5 Kavlico total19 AdditionalOrderingOptionsAdditionalorder ingoptionsareavailablefortheTracerUC600: TracerTD7 OperatorDisplay(ordernumber:X13651571010 ) TD7 SealedEthernetcable(forwetenvironments)( ordernumber:X19070632020) TD7 DisplayPortableCarryCase(ordernumber:X18 210613010) TD7 MountingBracket(flatsurface,fixedpositio n)(ordernumber:X05010511010) TracerXM30expansionmodule(ordernumber:X1 3651537010) TracerXM32expansionmodule(ordernumber:X1 3651563010) TracerXM70expansionmodule(ordernumber:X1 3651568010) TracerXM90expansionmodule(ordernumber:X1 3651673010) TracerBACnetTerm(2pack)(ordernumber.)


Related search queries