Transcription of Traffic CONIPUR II DECK COATING SYSTEM …
1 DescriptionConipur II deck COATING SYSTEM is afluid-applied polyurethanewaterproofing SYSTEM . CONIPUR II usesa fast-setting two- component reactivecuring mechanism. It has a very lowodor and is VOC II deck COATING SYSTEM iscomposed of: CONIPUR 78 primer , a two- component polyurethane-basedadhesive 265-Z BASE COAT, a two- component fast-curing polyurethanebase coat with outstandingmechanical properties includingexcellent 275 TOP COAT,a two- component fast-curing aromaticpolyurethane topcoat with outstandingmechanical properties, including hightensile strength, and excellent tear andabrasion 295 (Exterior applications)
2 Isa high performance, two-componentaliphatic, 100% solids urethanewaterproofing membrane designed asa topcoat for the CONIPUR II DeckCoating chart on page 78 primer : gallon ( L) kitsConipur 265-Z Base Coat: gallon ( L) kitsConipur 275 Top Coat: gallon ( L) kitsConipur 295 Top Coat: 5 gallon ( L) unitColors*Colors are approximate; conduct final color matching with actualmaterialShelf Life1 year when properly storedStorageStore in unopened containers in cool,clean, dry to UseAPPLICATION Parking garages Mechanical rooms Stadiums Balconies Plaza decksLOCATION Interior or exterior Above gradeSUBSTRATE Elevated concrete slabs Exterior grade plywoodFeaturesBenefits VOC compliantEnvironmentally responsible Two-componentProvides fast setting time, even in cooler climates.
3 Reduces facility downtime Low odor/99% solidsMay be used over or near inhabited structures; Non-flammable, solvent free Seamless waterproof membraneProtects concrete from freeze/thaw damage; protectsoccupied areas below from water damage; has noseams that may result in leaks Excellent chloride resistanceProtects from chloride intrusion; extends the life ofreinforcing steel Excellent chemical resistanceProtects against common parking deck chemicalsincluding gasoline,diesel fuel, oil, alcohol, ethyleneglycol, de-icing salt, bleach and cleaning agents Skid resistantIncreases safety, offers excellent durability andsuperior abrasion resistanceCONIPUR II deck COATING SYSTEMHigh-solids polyurethane waterproofing, Traffic bearing membrane systemsfor vehicular and pedestrian areasPRODUCT DATAT raffic Coatings07 18 007 GrayCharcoalBlack Distributed by.
4 BEST MATERIALS LLC, Phoenix AZPh: 800-474-7570, 602-272-8128 Fx: 602-272-8014 Email: PRODUCT DATACONIPUR II deck COATING SYSTEMT echnical DataCompositionConipur II deck COATING SYSTEM is a two-componentpolyurethane PropertiesSolids content,% CONIPUR 78 primer 99 CONIPUR 265-Z Base Coat99 CONIPUR 275 Top Coat99 CONIPUR 29599 Viscosity,cps CONIPUR 78 primer 630 CONIPUR 265-Z Base Coat3,400 CONIPUR 275 Top Coat1,600 CONIPUR 2953,000 Working Time,min* CONIPUR 78 primer 30 10 CONIPUR 265-Z Base Coat20 5 CONIPUR 275 Top Coat20 5 CONIPUR 29525 5 Initial cure.
5 Hrs CONIPUR 78 primer 2 3 CONIPUR 265-Z Base Coat3 4 CONIPUR 275 Top Coat3 4 CONIPUR 2954 8*Tested at 73 F (23 C) and 50% relative humidity. Warmtemperatures will shorten pot life; plan work VALUETest DataCrack bridging,Passes No cracking ASTM C 957 CONIPUR 265-Z Base CoatAdhesion peel,pli, primer and Base CoatASTM C 957 Plywood 253 Concrete 145 Tensile strength,psi (MPa), Base Coat 2,500 ( )
6 Control ASTM D 412 Elongation,%, Base Coat900 Control ASTM D 412 Tensile strength,psi (MPa), 275 Top Coat3,000 ( )Control ASTM D 412 Tensile strength,psi (MPa), 295 Top Coat2,980 ( )Control ASTM D 412 Elongation,%, 275 Top Coat30 Control ASTM D 412 Elongation,%, 295 Top Coat375 Control ASTM D 412 Hardness,Shore D 275 Topcoat70 ASTM D 2240 Hardness,Shore D 295 Topcoat45 ASTM D 2240 Taber abrasion resistance,mgms;100 ASTM D 4060CS-17 Wheel, 1,000 g load, 1,000 cycles, primer /Base Coat/275 Top CoatTaber abrasion resistance,mgms;58 ASTM D 4060CS-17 Wheel,1,000 g load,1,000 cycles, primer /Base Coat/Intermediate 275/295 Top CoatTest results are averages obtained under laboratory conditions.
7 Reasonable variations can be RESULTSSPECIFICATIONSTEST METHODSHow to ApplySurface PreparationCONCRETE1. Concrete must be fully cured (28 days),structurally sound, clean and dry (ASTM D 4263). Allconcrete surfaces (new and old) must be shotblastedto remove previous coatings,laitance and allmiscellaneous surface contamination and to provideprofile for proper adhesion. Abrasive shotblastingmust occur after concrete repair has taken is not permitted.
8 Proper profile shouldbe a minimum of ICRI CSP-3 (approximately 80 100 grit sandpaper.)2. Repair voids and delaminated areas with BASFC onstruction Chemicals branded cementitious andepoxy patching application when fast-turn repairs are required, CONIPUR 265 can be usedto repair patches up to 1 (25 mm) in depth. Pleaserefer to Technical Service for proper All units must be applied within the specified PRESTRIPING AND with CONIPUR 78 primer 1" (25 mm)beyond all surfaces that require detail work, using ashort-nap before application of CONIPUR 78 primer , remove all dust, dirt, and CONIPUR 78 primer to dry tack free.
9 On thesame day, coat primed surfaces with 25 30 wetmils ( mm) of CONIPUR 265-Z Base the For nonmoving joints and cracks less than 1/16"( mm) wide,apply 25 30" ( mm) wetmils prestriping of CONIPUR 265-Z Base Coat overcured CONIPUR 78 primer . Apply the Base Coat to filland overlap the joint or crack 3" (76 mm) on eachside. Feather the Dynamic cracks and joints over 1/16" ( mm)wide must be routed to a minimum of 1/4 by 1/4"(6 by 6 mm) and bondbreaker tapeto prevent adhesion to bottom of joint. Prime jointfaces only with Sonneborn primer 733 and fill withSonneborn SL 1 or SL 2.
10 Fill joints deeper than1/4" (6 mm) with appropriate backer rod and SL 2 or NP 1 /NP 2 sealants. For cracks, sealant shouldbe flush with the adjacent surface. For expansionjoints, sealant should be slightly Sealed joints 1" (25 mm) or less can be coatedover with the CONIPUR SYSTEM . Expansion jointsexceeding 1" (25 mm) wide, including the primarywide expansion-joint SYSTEM ,are not to be coated sothey can perform independently of the deck Form a sealant cant into the corner at thejunction of all horizontal and vertical surfaces (wallsections, curbs, columns) by priming with Primer733 and applying a 1/2 1" (13 25 mm) widebead of Sonneborn NP 1 or NP 2.