Example: marketing

Trem-Lar LRM - Tremco Roofing

Composition: Trem-Lar LRM is a single component, bitumenmodified moisture curing Uses: Trem-Lar LRM is designed as the waterproofingmembrane in a fully adhered protected membrane roof sys-tem for structural concrete to UL Roofing Materials and Systems Directory and/orFM Approvals for applicable system : Not intended for twin-slab, precast, or lightweight con-crete. Not for use as a traffic-bearing surface. Trem-Lar LRM requires acceptable protective surfacing suchas insulation with ballast, pavers, reflective and protectivecoatings, decorative surfaces, and protective covers. Concrete substrates must be free of all traces of bitumen prior to application of Trem-Lar : Horizontal areas: Squeegee ( Trem-Lar LRM-H)Vertical surfaces: Trowel ( Trem-Lar LRM-V)Equipment: Triangular notched squeegee to provide 60 mil( ) thick uniform : Available in 5 gallon ( ) : BlackStorage Life: Up to 12 months in unopened Standards: Meets or exceeds performance stan-dards of ASTM C LRMA One-Part Liquid Applied ElastomericRoofing MembraneRoofing & Weatherproofing Peace of Mind APPLICATION DATA:Conditions:Do not begin work during rainy or inclement weather or whensuch weather is imminent.

Composition : Trem-Lar®LRM is a single component, bitumen modified moisture curing polyurethane. Basic Uses: Trem-Lar LRM is designed as the waterproofing membrane in a fully adhered protected membrane roof sys-

Tags:

  Terms, Moisture, 174 lmr, Trem lar lrm, Trem lar

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Trem-Lar LRM - Tremco Roofing

1 Composition: Trem-Lar LRM is a single component, bitumenmodified moisture curing Uses: Trem-Lar LRM is designed as the waterproofingmembrane in a fully adhered protected membrane roof sys-tem for structural concrete to UL Roofing Materials and Systems Directory and/orFM Approvals for applicable system : Not intended for twin-slab, precast, or lightweight con-crete. Not for use as a traffic-bearing surface. Trem-Lar LRM requires acceptable protective surfacing suchas insulation with ballast, pavers, reflective and protectivecoatings, decorative surfaces, and protective covers. Concrete substrates must be free of all traces of bitumen prior to application of Trem-Lar : Horizontal areas: Squeegee ( Trem-Lar LRM-H)Vertical surfaces: Trowel ( Trem-Lar LRM-V)Equipment: Triangular notched squeegee to provide 60 mil( ) thick uniform : Available in 5 gallon ( ) : BlackStorage Life: Up to 12 months in unopened Standards: Meets or exceeds performance stan-dards of ASTM C LRMA One-Part Liquid Applied ElastomericRoofing MembraneRoofing & Weatherproofing Peace of Mind APPLICATION DATA:Conditions:Do not begin work during rainy or inclement weather or whensuch weather is imminent.

2 Rainfall will damage freshly appliedmaterial. Minimum recommended ambient air temperatureduring application: 40 F (4 C) and rising. Maximum allowedsurface temperature during application: 110 F (43 C).SURFACE PREPARATION:Concrete: Surface shall be dry, free of dust, oil, bitumen, cur-ing agents, form release agents, and other strength: 2,500 psi (17237 kPa), minimum. Theconcrete shall have a light steel trowel finish followed by anatural hairbroom to render a uniform granular texture. Newconcrete must cure 28 days minimum by either water, burlapor polyethylene cure , shotblast, or scarify existing concrete to assure thesubstrate is free of contamination and it has the proper surfacetexture to assure adhesion of the Trem-Lar the dry condition of the concrete with a rubber mattest. After taping the mat to the concrete for at least 24 hours,no liquid water droplets should be present on the undersideof the mat.

3 A valid test requires the concrete be warmed bythe sun during the :Clean metal surfaces of paint, oils, rust, and other /PREPARATORY WORK: Priming for Detail Course: Prime concrete detail areas with AlphaGuard C-Prime prior to application of Trem-Lar primer to fully dry prior to application of Trem-Lar penetrations:Provide a 1 x 1 (25 x 25mm) cant ofTrem-Lar LRM-V at parapet walls, columns, stacks, etc. InstallTrem-Lar LRM as a flashing to the specified height Extendflashing 6 (150mm) onto horizontal surface. Coating thick-ness: 60 mils ( ) (wet).Cracks of 1/16 ( ) or less:Pretreat shrinkage and non-moving structural cracks with Trem-Lar LRM applied at a thick-ness of 60 mils ( ) (wet) 3 (75mm) either side of of 1/16 ( ) or greater:Rout all cracks, movingstructural joints, and cold joints to 1/4 wide x 1/2 ( ) deep.

4 Insert a 3/8 ( ) closed-cell polyethylenebacker rod. Recess backer rod 1/8 ( ) from surface. Fillrecess with Trem-Lar LRM applied at a thickness of 60 mils( ) (wet) 3 (75mm) either side of the crack/joint. Propertreatment of expansion joints is critical. Consult your localTremco Representative for AdvantagesFeaturesBenefitsFully bonded to concrete Reduces potential forwater migration undermembraneCold applied Can be used in difficultaccess areas No hot kettlesOne-part No mixing or specialequipment neededOne coat application Labor savingsLow modulus Accommodates typicalHigh elongationmovementHigh recoveryAPPLICATION: Priming Concrete/Masonry: Prime all concrete and verticalmasonry with AlphaGuard C-Prime. AlphaGuard C-Prime mustdry tack free (6 to 8 hours at 75 F (24 C) and 50% ) priorto application of Trem-Lar LRM.

5 Open time of AlphaGuard C-Prime is 72 hours after tack free cure. Trem-Lar LRM must beapplied within the open time. If open time is exceeded, sub-strate must first be mechanically abraded, then , prime concrete substrates with Tremlar LRM-Hthinned with toluene at a rate of 32 oz. toluene per gallon ofTrem-Lar LRM-H. Apply the thinned Trem-Lar LRM-H to theclean, dry surface at a coverage rate of 1 gal/SQ ( L/m2)Allow to dry 1 hour minimum and apply the specified cover-age of Trem-Lar LRM-H (must be applied the same day).Priming Trem-Lar LRM: If Trem-Lar LRM has been applied andcured in excess of 48 hours and an additional coat of Trem-LarLRM must be applied, prime the existing Trem-Lar LRM with Ge-oGard Primer. Apply Trem-Lar LRM while GeoGard Primer is : Apply Trem-Lar LRM-H directly to surface bysqueegee and cross-roll with a long nap roller to a uniform thick-ness.

6 Overlap previous day s work 6 (150mm) : 25 ft2/gal. ( ) per coat Test: Allow membrane to cure 36 hours minimum(75 F (24 C) @ 60% RH). Longer cure times will be requiredat lower temperatures and/or to placement of protective surfacing, water test appliedarea. Block drains and provide perimeter dams. Flood testarea with water for 48 hours. Do not exceed deck design loadrequirements during water Time: 24 hours at 75 F (24 C), 50% RH. Longer curetimes will result at lower temperatures and/or lower relative : Use Xylene or Toluene to remove Trem-Lar LRMfrom equipment before cure. Precautions: Users must read and follow container labels andMaterial Safety Data Sheets for instructions for health andsafety precautions prior to and during and Cost:Contact your local Tremco RoofingRepresentative for pricing and availability.

7 For the name andnumber of your Representative, call the Roofing Division at216 :Your local Tremco Roofing Representative canprovide you with effective maintenance procedures whichmay vary, depending upon specific conditions. Periodic in-spections, early repairs and preventive maintenance are allpart of a sound roof : Tremco Inc. warrants Trem-Lar LRM tobe free of defects and to meet published physical propertieswhen tested according to ASTM and Tremco this warranty, any Trem-Lar LRM product that is provedto be defective when applied in accordance to our written in-structions, and in applications recommended by Tremco assuitable for this product will be replaced with like product atno charge. THIS IS BUYERS SOLE AND EXCLUSIVE claims concerning product defects must be made in writ-ing within twelve (12) months of shipment.

8 The absence ofsuch claims in writing during this period will constitute awaiver of all claims with respect to such warranty shall be IN LIEU OF any other warranty, expressor implied, including but not limited to, any implied warrantyof MERCHANTABILITY OR FITNESS FOR A PARTICULAR Services:Your local Tremco Representative, work-ing with the Technical Service Staff, can help analyze condi-tions and needs to develop recommendations for specialapplications. The services of the Tremco Research Center,which has earned a unique reputation in weatherproofingtechnology, complement and extend the services of theTremco Technical Service of Policy and Responsibility: Tremco takes re-sponsibility for furnishing quality materials and for providingspecifications and recommendations for their proper neither Tremco itself nor its Representatives practice archi-tecture or engineering, Tremco offers no opinion on, and ex-pressly disclaims any responsibility for the soundness of anystructure or any components below the building structure onwhich its products may be applied.

9 If questions arise as to thesoundness of a structure, its ability to support a planned in-stallation properly, or whether material below the structurewill be disturbed, the Owner should obtain the opinion ofcompetent structural engineers before proceeding. Tremcoaccepts no liability for any failure of the structure or materialbelow the structure or for resultant damages, and no TremcoRepresentative is authorized to vary this Green RoadBeachwood, OH 44122216-292-5000220 Wicksteed AveToronto, ONT M4H 1G7416-421-3300R-754001 Rev. 3/17 Printed in USAP hysical Performance CharacteristicsTrem-Lar LRMT ypical ValuePropertyHorizontal Vertical Test MethodGradeGradeUltimate elongation950%700%ASTM D 412-92 Ultimate tensile strength 300psi250 psiASTM D 412-92(21 kg/cm2) ( kg/cm2)Recovery from 350% 95%90%ASTM D 412-92elongationHardness (Shore A)2538 ASTM D 2240-86 Hardness (Shore OO)80 - 9585 - 90 ASTM C 836-89 Water vapor permeance metric metric ASTM E 96-80perms*perms*Low temperature>500%>500%ASTM D 412-92elongation @ -20 F(-29 C)Service temperature-40 F to-40 F toASTM D 412-92(continuous ambient) 150 F150 F(-40 C to (-40 C to 66 C)66 C)Nonvolatile content87%81%ASTM D 2369-87 Volatile organic compound 110 g/L110 g/LASTM D3960-89(less water, less exemptsolvents)Viscosity @ 77 F (25 C)

10 7,000 -30,000 -ASTM D 2196-8612,000 cP50,000 cP(7-12Pa s) (30-50Pa s)Density @ 77 F (25 C) lb/gal ASTM D 70-82(1052g/L)(1088g/L)(1986)Flash point>100 F>100 F ASTM D 3278-82(>38 C)(>38 C)*Metric perms = (g/m2) (24h) (mm Hg)