Example: confidence

TYPICAL MANIFOLD SYSTEM - Franklin Fueling …

TYPICAL MANIFOLD SYSTEM4 TANKS RECOMMENDED TO BE OF SAME DIAMETERS OR WITH TOP OF TANKS ON THE SAME MUST CONFORM TO APPLICABLENATIONAL, STATE, AND LOCAL CODE REQUIREMENTSIN THIS TYPE OF INSTALLATION, A SUBMERGED PUMP INEACH TANK #1 & #2 SUPPLIES ONE DISCHARGE LINE. BYTHE USE OF VALVES AS SHOWN, ONE PUMP WILL SUPPLYTHE DISCHARGE LINE TEMPORARILY. TO USE SUBMESIBLETANK #1 ONLY, CLOSE VALVE "B" WITH VALVE "A" NORMALLYOPEN. TO USE SUBMERSIBLE TANK #2 ONLY, CLOSE VALVE "A"(FOR DISPENSING ONE PRODUCT WITH TWO SUBMERSIBLES)NORMALLY :2 SWING JOINT MAY BE APPLICABLE REPLACEMENT FOR FLEX CONNECTOR.

typical manifold system 4 tanks recommended to be of same diameters or with top of tanks on the same plane. installation must conform to applicable

Tags:

  System, Franklin, Manifolds, Typical, Typical manifold system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TYPICAL MANIFOLD SYSTEM - Franklin Fueling …

1 TYPICAL MANIFOLD SYSTEM4 TANKS RECOMMENDED TO BE OF SAME DIAMETERS OR WITH TOP OF TANKS ON THE SAME MUST CONFORM TO APPLICABLENATIONAL, STATE, AND LOCAL CODE REQUIREMENTSIN THIS TYPE OF INSTALLATION, A SUBMERGED PUMP INEACH TANK #1 & #2 SUPPLIES ONE DISCHARGE LINE. BYTHE USE OF VALVES AS SHOWN, ONE PUMP WILL SUPPLYTHE DISCHARGE LINE TEMPORARILY. TO USE SUBMESIBLETANK #1 ONLY, CLOSE VALVE "B" WITH VALVE "A" NORMALLYOPEN. TO USE SUBMERSIBLE TANK #2 ONLY, CLOSE VALVE "A"(FOR DISPENSING ONE PRODUCT WITH TWO SUBMERSIBLES)NORMALLY :2 SWING JOINT MAY BE APPLICABLE REPLACEMENT FOR FLEX CONNECTOR.

2 PIPING OTHER THAN INDICATED TO BE PER CUSTOMER MANIFOLDED SYSTEM OPERATIONTANK #1 TANK #2 FILLVENTBALL VALVE "A"DISCHARGE LINE(NORMALLY OPEN)BALL VALVE "B"(NORMALLY OPEN)SYPHON SYSTEMMECHANICAL LINE LEAK DETECTOR(VENTED BACK TO TANK PORT)43 MECHANICAL LINE LEAK DETECTORS WILL NOT DETECT LEAKS PRIOR TO THE LEAK DETECTOR TEE HOUSING. MINIMIZE PIPING BETWEEN THE TEE HOUSING AND THE SUBMESIBLES.(SINGLE PRODUCT LINE DELIVERY)LEAK DETECTOR TEE HOUSINGFLEX CONNECTOR(WITH SWIVELS)5 A SYPHON SYSTEM MAY BE DESIRED WITH THIS CONFIGURATION TO UTILIZE FULL STORAGE CAPACITY OF THE TANKS AND REDUCE THE POSIBILITY OF RUNNING A PUMP IN A DRY CONDITION.

3 THE SUGGESTED SYPHON SYSTEM WOULD BE INSTALLED AS SHOWN ABOVE, WITH THE HIGHEST POINTS OF THE SYPHON LINE CONNECTED AT EACH END TO THE SYPHON CHECK VALVE ASSEMBLY AT EACH SUBMERSIBLE. THE SYPHON WOULD BE INSTALLED LIKE THAT OF A TYPICAL SYPHON SYSTEM , REFERENCE ENGINEERING SKETCH ENGSK12 FOR COMPLETE DETAILS, EXCEPT THE SYPHON LINE MUST BE INSTALLED LEVEL RATHER THAN PITCHING UP TOWARD EITHER SUBMERSIBLE AS IN A TYPICAL SYPHON SYSTEM NOBYDATE1 ENGINEERING RELEASE-----BCG2/19/97 NONE1 1 MANIFOLD 2 STP / 1 MLD ISO---ENGSK11 ATITLE:DRAWN:APPRVL:DATE:DATE:SCALE:SHEE TOFDRW NO:SUFFIX:MATERIAL:SPECIAL DIST.

4 HIGH PRODOTHERPIPE PRODPMA PRODCONTROL BOXSTP PRODMLD PRODSTP KITTINGMcFarland, WI 53558 The information disclosed hereon includes proprietary rights of FE Petro, Inc. Neither this drawingnor the information disclosed thereon may be reproduced or transferredto other documents, or used ordisclosed to others for any purpose, except as specifically authorizedmust be returned to FE Petro upon writing by FE Petro. This drawingDO NOT SCALE DRAWINGSTANDARD INCH TOLERANCES(UNLESS OTHERWISE SPECIFIED).XX ..0005+++ ..0010+++---OVER 6"UNDER 6"ANGULAR 1/2+-FRACT 1/64+-SPARE PARTS4521312 ENLARGE TEXTDPK3/10/97