**USACE / NAVFAC / AFCEC / NASAUFGS-26 05 40 (November 2020)----------------------------------- -Preparing Activity: NASAS upersedingUFGS-26 05 40 (August 2019)UNIFIED FACILITIES GUIDE SPECIFICATIONSR eferences are in agreement with UMRL dated October 2021**SECTION TABLE OF CONTENTSDIVISION 26 - ELECTRICALSECTION 26 05 40 Common WORK Results FOR ELECTRICAL11/20 PART 1 GENERAL REFERENCES DEFINITIONS SUBMITTALS QUALITY CONTROL Regulatory Requirements Standard ProductsPART 2 PRODUCTS EQUIPMENT Conduits and Raceways Rigid Steel Conduit Electrical Metallic Tubing (EMT) Flexible Metallic Conduit Intermediate Metal Conduit Rigid Nonmetallic Conduit Surface Metal Raceway Surface Nonmetallic Raceway Wireways Cable Trays Outlet Boxes, Pull Boxes and Junction Boxes Panelboards Circuit Breakers Dry-Type Distribution Transformers General Requirements Transformer Factory Tests MATERIALS Wire And Cable Insulation Wire and Cable for 400 Hertz (Hz) Circuits Metal-Clad Cable Armored CableSECTION 26 05 40 Page 1 Mineral-Insulat

3.2.7.9 Conduit Installed Through Floor Slabs 3.2.7.10 Conduit Installed in Concrete Floor Slabs 3.2.7.11 Stub Ups 3.2.7.12 Conduit Support 3.2.7.13 Directional Changes in Conduit Runs 3.2.7.14 Wireway and Auxiliary Gutter 3.2.7.15 Surface Raceways and Assemblies 3.2.7.16 Cable Trays 3.2.8 Wiring SECTION 26 05 00.00 40 Page 2

Tags:

  Through, Wireway

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of UFGS 26 05 00.00 40 Common Work Results for Electrical

1 **USACE / NAVFAC / AFCEC / NASAUFGS-26 05 40 (November 2020)----------------------------------- -Preparing Activity: NASAS upersedingUFGS-26 05 40 (August 2019)UNIFIED FACILITIES GUIDE SPECIFICATIONSR eferences are in agreement with UMRL dated October 2021**SECTION TABLE OF CONTENTSDIVISION 26 - ELECTRICALSECTION 26 05 40 Common WORK Results FOR ELECTRICAL11/20 PART 1 GENERAL REFERENCES DEFINITIONS SUBMITTALS QUALITY CONTROL Regulatory Requirements Standard ProductsPART 2 PRODUCTS EQUIPMENT Conduits and Raceways Rigid Steel Conduit Electrical Metallic Tubing (EMT) Flexible Metallic Conduit Intermediate Metal Conduit Rigid Nonmetallic Conduit Surface Metal Raceway Surface Nonmetallic Raceway Wireways Cable Trays Outlet Boxes, Pull Boxes and Junction Boxes Panelboards Circuit Breakers Dry-Type Distribution Transformers General Requirements Transformer Factory Tests MATERIALS Wire And Cable Insulation Wire and Cable for 400 Hertz (Hz)

2 Circuits Metal-Clad Cable Armored CableSECTION 26 05 40 Page 1 Mineral-Insulated, Metal-Sheathed Cable Cable Tray Cable or Power Limited Tray Cable Cord Sets and Power-Supply Cords Device Plates Switches Safety Switches Toggle Switches Fuses Fuseholders Cartridge, Current Limiting Type (Class R) Cartridge Fuses, High-Interrupting Capacity, Current Limiting Type (Classes J, L, and CC) Cartridge Fuses, Current Limiting Type (Class T) Receptacles Switched Duplex Receptacles Weatherproof Receptacles Ground-Fault Circuit Interrupter Receptacles Special Purpose Receptacles Plugs Tamper-Resistant Receptacles Manufacturer's Nameplate Warning Signs Firestopping Materials Metering Surge Protective DevicesPART 3 EXECUTION PREPARATION INSTALLATION Underground Service Overhead Service Hazardous Locations Service Entrance Identification Labels Wiring Methods Pull Wire Metal Clad Cable Armored Cable Mineral Insulated, Metal Sheathed (Type MI) Cable Installation Conduits, Raceways and Fittings Rigid Steel Conduit Electrical Metallic Tubing (EMT)

3 Flexible Metallic Conduit Intermediate Conduit Rigid Nonmetallic Conduit Underground Conduit Conduit for Circuits Rated Greater Than 600 Volts Conduit Installed Under Floor Slabs Conduit Installed through Floor Slabs Conduit Installed in Concrete Floor Slabs Stub Ups Conduit Support Directional Changes in Conduit Runs wireway and Auxiliary Gutter Surface Raceways and Assemblies Cable Trays WiringSECTION 26 05 40 Page 2 Wiring Devices Wall Switches and Receptacles Device Plates Splices and Connectors Conductor Identification Marking Strips Safety Switches Boxes and Fittings Covers and Device Plates Electrical Penetrations Panelboards Dry-Type Distribution Transformers Surge Protective Devices Field Fabricated Nameplates Identification Plates and Warnings FIELD FABRICATED NAMEPLATE MOUNTING WARNING SIGN MOUNTING FIELD APPLIED MOUNTING FIELD QUALITY CONTROL-- End of Section Table of Contents --SECTION 26 05 40 Page 3**USACE / NAVFAC / AFCEC / NASAUFGS-26 05 40 (November 2020)----------------------------------- -Preparing Activity: NASAS upersedingUFGS-26 05 40 (August 2019)UNIFIED FACILITIES GUIDE SPECIFICATIONSR eferences are in agreement with UMRL dated October 2021**SECTION 26 05 40 Common WORK Results FOR ELECTRICAL11/20**NOTE.

4 This guide specification covers the requirements for Common to all Electrical to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable item(s) or insert appropriate information and requirements not required in respective project, whether or not brackets are , suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).**PART 1 REFERENCES**NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and the Reference Wizard's Check Reference feature when you add a Reference Identifier (RID) outside of the Section's Reference Article to automatically place the reference in the Reference Article.

5 Also use the Reference Wizard's Check Reference feature to update the issue 26 05 40 Page 4 References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.**The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation NATIONAL STANDARDS INSTITUTE (ANSI)ANSI (2014; Errata 2016) Electric Meters - Code for Electricity MeteringAMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)ASCE 7-16(2017; Errata 2018; Supp 1 2018) Minimum Design Loads and Associated Criteria for Buildings and Other StructuresASTM INTERNATIONAL (ASTM)ASTM D709(2017) Standard Specification for Laminated Thermosetting MaterialsELECTRONIC INDUSTRIES ALLIANCE (EIA)EIA 480(1981) Toggle SwitchesINSTITUTE OF Electrical AND ELECTRONICS ENGINEERS (IEEE)IEEE C2(2017; Errata 1-2 2017.)

6 INT 1 2017) National Electrical Safety CodeIEEE (2014) Standard for Pad-Mounted Equipment - Enclosure IntegrityIEEE (2014) Standard for Pad-Mounted Equipment - Enclosure Integrity for Coastal EnvironmentsIEEE Stds Dictionary(2009) IEEE Standards Dictionary: Glossary of Terms & DefinitionsINTERNATIONAL CODE COUNCIL (ICC)ICC/ANSI (2009) Accessible and Usable Buildings and FacilitiesINTERNATIONAL Electrical TESTING ASSOCIATION (NETA)NETA ATS(2021) Standard for Acceptance Testing Specifications for Electrical Power Equipment and SystemsSECTION 26 05 40 Page 5 NATIONAL Electrical MANUFACTURERS ASSOCIATION (NEMA)ANSI (2014) Requirements for Watthour Meter SocketsANSI (2020) American National Standard for Electrical Rigid Steel Conduit (ERSC)ANSI (2020) American National Standard for Electrical Metallic Tubing (EMT)ANSI (2017) Safety ColorsANSI/NEMA OS 1(2013; R 2020) Sheet-Steel Outlet Boxes, Device Boxes, Covers, and Box SupportsANSI/NEMA OS 2(2013.

7 R 2020) Nonmetallic Outlet Boxes, Device Boxes, Covers, and Box SupportsNEMA 250(2020) Enclosures for Electrical Equipment (1000 Volts Maximum)NEMA AB 3(2013) Molded Case Circuit Breakers and Their ApplicationNEMA FB 1(2014) Standard for Fittings, Cast Metal Boxes, and Conduit Bodies for Conduit, Electrical Metallic Tubing, and CableNEMA FU 1(2012) Low Voltage Cartridge FusesNEMA ICS 1(2000; R 2015) Standard for Industrial Control and Systems: General RequirementsNEMA ICS 6(1993; R 2016) Industrial Control and Systems: EnclosuresNEMA KS 1(2013) Enclosed and Miscellaneous Distribution Equipment Switches (600 V Maximum)NEMA PB 1(2011) PanelboardsNEMA RN 1(2005; R 2013) Polyvinyl-Chloride (PVC) Externally Coated Galvanized Rigid Steel Conduit and Intermediate Metal ConduitNEMA ST 20(2014) Dry-Type Transformers for General ApplicationsNEMA TC 2(2020) Standard for Electrical Polyvinyl Chloride (PVC) ConduitNEMA TC 3(2021) Polyvinyl Chloride (PVC) Fittings for Use With Rigid PVC Conduit and TubingNEMA VE 1(2017) Metal Cable Tray SystemsNEMA WD 1(1999; R 2020) Standard for General Color SECTION 26 05 40 Page 6 Requirements for Wiring DevicesNEMA WD 6(2016) Wiring Devices Dimensions SpecificationsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 70(2020; ERTA 20-1 2020; ERTA 20-2 2020; TIA 20-1; TIA 20-2; TIA 20-3; TIA 20-4) National Electrical CodeNFPA 70E(2021) Standard for Electrical Safety in the WorkplaceTELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)TIA-222(2018H.

8 Add 1 2019) Structural Standard for Antenna Supporting Structures and Antennas and Small Wind Turbine Support StructuresUNDERWRITERS LABORATORIES (UL)UL 1(2005; Reprint Jan 2020) UL Standard for Safety Flexible Metal ConduitUL 4(2004; Reprint Mar 2021) UL Standard for Safety Armored CableUL 5(2016; Reprint Aug 2020) UL Standard for Safety Surface Metal Raceways and FittingsUL 5A(2015; Reprint Aug 2020) Nonmetallic Surface Raceways and FittingsUL 6(2007; Reprint Sep 2019) UL Standard for Safety Electrical Rigid Metal Conduit-SteelUL 20(2018; Reprint Jan 2021) UL Standard for Safety General-Use Snap SwitchesUL 44(2018; Reprint May 2021) UL Standard for Safety Thermoset-Insulated Wires and CablesUL 50(2015) UL Standard for Safety Enclosures for Electrical Equipment, Non-Environmental ConsiderationsUL 67(2018; Reprint Jul 2020) UL Standard for Safety PanelboardsUL 83(2017; Reprint Mar 2020) UL Standard for Safety Thermoplastic-Insulated Wires and CablesUL 198M(2018) UL Standard for Mine-Duty FusesUL 360(2013; Reprint Aug 2021) UL Standard for Safety Liquid-Tight Flexible Metal ConduitSECTION 26 05 40 Page 7UL 486A-486B(2018; Reprint May 2021) UL Standard for Safety Wire ConnectorsUL 486C(2018; Reprint May 2021) UL Standard for Safety Splicing Wire ConnectorsUL 489(2016; Rev 2019) UL Standard for Safety Molded-Case Circuit Breakers, Molded-Case Switches and Circuit-Breaker EnclosuresUL 498(2017; Reprint Feb 2021) UL Standard for Safety Attachment Plugs and ReceptaclesUL 506(2017) UL Standard for Safety Specialty TransformersUL 514A(2013; Reprint Aug 2017) UL Standard for Safety Metallic Outlet BoxesUL 514B(2012.

9 Reprint May 2020) Conduit, Tubing and Cable FittingsUL 514C(2014; Reprint Feb 2020) UL Standard for Safety Nonmetallic Outlet Boxes, Flush-Device Boxes, and CoversUL 651(2011; Reprint Mar 2020) UL Standard for Safety Schedule 40, 80, Type EB and A Rigid PVC Conduit and FittingsUL 797(2007; Reprint Mar 2021) UL Standard for Safety Electrical Metallic Tubing -- SteelUL 817(2015; Reprint Jul 2021) UL Standard for Safety Cord Sets and Power-Supply CordsUL 869A(2006; Reprint Jun 2020) Reference Standard for Service EquipmentUL 870(2016; Reprint Mar 2019) UL Standard for Safety Wireways, Auxiliary Gutters, and Associated FittingsUL 943(2016; Reprint Feb 2018) UL Standard for Safety Ground-Fault Circuit-InterruptersUL 1242(2006; Reprint Aug 2020) Standard for Electrical Intermediate Metal Conduit -- SteelUL 1283(2017) UL Standard for Safety Electromagnetic Interference FiltersUL 1449(2021) UL Standard for Safety Surge Protective DevicesUL 1561(2011; Reprint Jun 2015) Dry-Type General Purpose and Power TransformersSECTION 26 05 40 Page 8UL 1569(2018) UL Standard for Safety Metal-Clad CablesUL 4248-1(2017) UL Standard for Safety Fuseholders - Part 1: General RequirementsUL 4248-12(2018) UL Standard for Safety Fuseholders - Part 12: Class DEFINITIONSa.

10 Unless otherwise specified or indicated, Electrical and electronics terms used in these specifications, and on the drawings, are as defined in IEEE Stds The technical sections referred to herein are those specification sections that describe products, installation procedures, and equipment operations and that refer to this section for detailed description of submittal types.[c. Vertical assembly: A vertical assembly is a pole, tower or other such support, mounting hardware, arms, brackets and the load. Load can be a luminaire, siren, loudspeaker or other device. All components of a vertical assembly will be rated by the manufacturer to withstand [217][_____] kilometer/hour [150][_____] mph wind loading in accordance with [ASCE 7-16][TIA-222].] SUBMITTALS**NOTE: Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list, and corresponding submittal items in the text, to reflect only the submittals required for the project.