UPDATED GUIDANCE NOTE ON IMPROVING VENTILATION …
of carry-over leakage from exhaust air. 2.5. Increase ventilation in premises with limited ventilation and air filtration provision (e.g. meeting rooms with only FCU): a. Open operable windows and doors as frequently as possible9, unless outdoor/outside air quality is poor. Air-conditioning should be reduced or
Tags:
Ventilation, Estudio, Outside air
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
UPDATED GUIDANCE NOTE ON IMPROVING VENTILATION …
www1.bca.gov.sgoutdoor air quality is poor. Air-conditioning should be reduced or turned off when doors and/or windows are opened. b. Consider adding dedicated outdoor air supply and/or exhaust7. c. Operate exhaust fans (e.g. in toilets, kitchens) at full capacity to expel air from indoor spaces. Keep windows or other openings (e.g. back door)
CODE ON ENVELOPE THERMAL PERFORMANCE FOR …
www1.bca.gov.sgA2 Thermal Transmittance (U-value) 15 A3 Surface Air Film Resistance 15 A4 Air Space Resistance 16 . 3 APPENDIX B - Shading Coefficient of Sun Shading Devices B1 Basic Solar Data B1.1 Solar geometry 18 ... B2.3 Determination of ‘G’ factor 22 B3 Examples B3.1 Example A – finding the effective shading coefficient 26 ...
SPECIFIC REGISTRATION REQUIREMENTS FOR MECHANICAL ...
www1.bca.gov.sgMechanical, Electrical/Electronics Engineering or equivalent awarded by BCA Academy, Nanyang Polytechnic, Ngee Ann Polytechnic, Republic Polytechnic, Singapore Polytechnic, Temasek Polytechnic or such other diplomas or qualifications as approved by BCA from time to time. For ME05, an EMA electrician can be considered as one of the “T” for ...
Handbook to BC1: 2012
www1.bca.gov.sgTable 3.2f Design Strength of American (AWS) Stud Shear Connectors 11 Table 3.3a Design Strength of Japanese (JIS) Structural Steels 11 Table 3.3b Design Strength of Japanese (JIS) Non-Preloaded Bolts 12 Table 3.3c Design Strength of Japanese (JIS) Preloaded Bolts 12
CODE OF PRACTICE ON Buildability
www1.bca.gov.sgContents CODE OF PRACTICE Introduction 1 1 Scope 2 ... The following Act and Regulations have relevance: a. The Building Control Act. b. ... The various types of building development are categorised in Table A. Buildings listed
Guide on FM Procurement
www1.bca.gov.sgProcurement is a key enabler to FM transformation and in creating lead demand in the public sector. The FMIC’s Procurement Taskforce, set up to review and strengthen FM procurement practices, has consulted the Centre of Excellence for FM (JTC), various Government Procuring Entities (GPEs) and FM providers to prepare this Guide on FM Procurement.
Circular on Further Simplified Claim Process for ...
www1.bca.gov.sgTo: All firms registered in BCA’s Contractors Registration System (CRS) Circular on Further Simplified Claim Process for Prolongation Costs in Public Sector Construction Contracts due to COVID-19 Events Further to the BCA circular dated 27 …
System, Registration, Contractor, Contractors registration system
GREEN MARK AWARD
www1.bca.gov.sgCentral Library at National University of Singapore ... SUPER LOW ENERGY (SLE) BUILDINGS . 7 CONTENT PAGE Tiong Bahru Market Ulu Pandan Bus Depot (SBST) United World College of South East Asia ... 7 north coast 79 Anson Road Admirax …
STRATA MANAGEMENT GUIDE : 1
www1.bca.gov.sgThe MC, in respect of a strata title plan, is composed of the subsidiary proprietors (SPs) within the specific strata title plan. A SP is a purchaser to whom ownership of a unit has been transferred, as shown on the subsidiary strata certificate of title. 1.2 The Building Maintenance and Strata Management Act (BMSMA) is designed to
Management, Strata, Strata management, Strata management act
Ops START - bca.gov.sg
www1.bca.gov.sg1. Tilt the buffer bottle 2. Fill the extraction tube with buffer fluid until it reaches the fill-line of the extraction tube 3. Close the nozzle (blue cap) Test cartridge, swab stick, and extraction tube with buffer solution to be provided to the employee to conduct self-swabbing.
Related documents
ASHRAE Technical FAQ
www.ashrae.org62.1-2016, "Ventilation for Acceptable Indoor Air Quality", plus ASHRAE BOD approved addenda. This standard specifies outside air ventilation rates and maximum levels of indoor contaminants and other chemicals for acceptable indoor air quality. Copies of the standard, the latest addenda, and other publications may be
Healthy homes standards – Ventilation
www.tenancy.govt.nzhealthy homes ventilation standard. However, they can continue to be used in homes and may meet the standards if additional materials or fittings such as external ducting are installed to enable them to ventilate to the outside. For the ventilation standard, a ‘kitchen’ means a room with an indoor cooktop, and a ‘bathroom’ means
Guidelines for attic ventilation
docserver.nrca.netIn a balanced ventilation configuration, ambient outside air enters into the attic space via soffit or eave vents; this air passes through the attic space where it displaces warm, moisture-laden air, which, in turn, exits the attic via vents at or near the top of the space being vented. This configuration relies on
Part 9 – Housing and Small Buildings Section 9.32. Ventilation
www2.gov.bc.caintroduce outside air to, that room or space at the rate of a) one-half air change per hour if the room or space is mechanically cooled during the non-heating season, or b) one air change per hour if it is not mechanically cooled during the non-heating season. 9.32.2.2. Non-Heating-Season Natural Ventilation
Interpretation of Air Test Results - Consumer Mold Guide
www.consumermoldguide.orgOutside air, furthermore, has less of an influence on indoor air quality than it has in the past due to tighter, ... Mold is a fungus that thrives on moisture and poor ventilation. Molds are present everywhere - indoors and outdoors. In fact, there are more than 100,000 species of mold. They serve an important role by helping to break down ...
Ventilation Solutions Fresh Air Solutions for Ductless ...
www.fantech.nethome can be as much as 10 times more polluted than outside air. What it means to you Good ventilation protects you, your family, and your guests from unpleasant odors, irritating pollutants, and potentially dangerous gases like carbon monoxide. A well-designed and properly operated ventilation system also prevents the
Solutions, Ventilation, Fresh, Estudio, Ventilation solutions fresh air solutions, Outside air
uidance for uilding perations During the CID- Pandemic
www.ashrae.org• Increase outdoor air ventilation (use caution in highly polluted areas); with a lower population in the building, this increases the effective dilution ventilation per person. • Disable demand-controlled ventilation (DCV). • Further open minimum outdoor air dampers, as high as 100%, thus eliminating recirculation (in the mild
GUIDELINES ON HEATING, VENTILATION AND AIR …
www.who.intHeating, ventilation and air-conditioning108 (HVAC) play an important role in ensuring the manufacture109 of quality pharmaceutical products. The good manufacturing practice (GMP) requirements of the prevention of contamination110 and cross-contamination are an essential 111 design consideration of an HVAC system. A well designed HVAC system ...
G1849 Air Properties: Temperature and Relative Humidity
extensionpublications.unl.eduair we breathe and use for ventilation. • Dry air. exists when all of the contaminants and water vapor have been removed from atmospheric air. By volume, dry air contains about 78 percent nitrogen, 21 percent oxygen, and 1 percent other gases. Dry air is used as the reference in psychrometrics. • Moist air. is a mixture of dry air and water ...
Indoor Air Quality in Commercial and Institutional Buildings
www.osha.govJan 24, 2003 · heating, ventilating and air-conditioning (HVAC) systems, overcrowding, radon, moisture incursion and dampness, presence of outside air pollutants, and the presence of internally generated contami-nants such as use of cleaning and disinfecting supplies and aerosol products, off-gassing from materials in the building, and use of mechanical