Transcription of V47 Series Temperature Actuated Modulating Water Valves
1 Master Catalog 125. Valves , Miscellaneous (Other Than Gas) Section V. Product Bulletin V47. Issue Date 0518. V47 Series Temperature Actuated Modulating Water Valves Application Temperature Actuated three-way diverting Valves are available for The V47 Modulating Valves special applications. Contact regulate the flow of Water to Customer Service for additional maintain a desired Temperature . information. V47A Valves OPEN on a Temperature increase at the bulb For use with liquids other than while V47N Valves CLOSE on a Water , contact Customer Temperature increase at the Service. bulb. Refer to LIT-125687 for All Series V47 Water pressure Actuated Water Valves . regulating Valves are designed The V47 Temperature Valves are for use only as operating widely used on heat exchangers devices. Where system to maintain optimum operating closure, improper flow or loss temperatures of internal of pressure due to valve combustion engines, air failure can result in personal compressors, hydraulic oil, etc.
2 Injury and/or loss of property, Important benefits from the use a separate pressure relief or of Water Valves include safety shutoff valve, as Fig. 1 -- V47 Temperature maximum operating efficiency of applicable, must be added by the equipment and a substantial Actuated Water Valve. the user. savings effected by the conservation of Water flow. They Free movement of all parts are used on condenser Features provides smooth applications where expensive Temperature modulation. No close fitting sliding parts fluids are economically in Water passages. Adjustment not affected by recovered or where the use of Water pressure variations. cooling Water is restricted and Range spring does not come on such varied applications as in contact with the cooling Withstands high hydraulic the Temperature control of Water . shock without damage. swimming pools and the control of paint temperatures on Easy manual flushing, if industrial printing machines.
3 Required. Valve design minimizes chatter and Water hammer. This product is made of copper alloy, which contains lead. The product is therefore not to be Specifications used on drinking Water . General Description 2018 Johnson Controls 1. Code No. LIT-125690. General Description A pressure-balanced design, employing synthetic rubber sealing diaphragms correctly proportioned to the valve port area, balances Valves against both gradual and sudden Water pressure changes, seals Water away from range spring and guides and provides protection against high Water surge pressures. Range spring and sliding parts are not submerged in Water where they would be subject to sedimentation and corrosion. Only five metal parts, made of corrosion. Only five metal parts, made of corrosion resistant material, come in contact with the Water -- valve disc holder, disc stud, valve seat, valve stem, and body. (See Fig 2.)
4 IMPORTANT: Before using this chart determine type of bulb needed in particular application. Table 1 -- Heating Bulb -- Bulb Temperature is always HIGHER than bellows Temperature . Table 2 -- Cross-ambient Bulb -- Bulb Temperature rises higher and drops lower than bellows Temperature . Recommended for general use with standard 75 to 135 F (24 to 57 C) range to maintain control at bulb location. Note: To provide satisfactory operation, always install valve with bellows down and spring cage up. Capillary end of Temperature Fig. 2 -- Typical cross- bulb should always be higher than plugged-end of bulb, or if sections of threaded type horizontal, the word TOP should be at the top or uppermost Valves . Interiors of flange surface of bulb. models are similar. Never subject Temperature bulb to temperatures in excess of 20F (11C ) above maximum range Temperature . Example: 75 to 135 F (24 to 57 C) range; maximum bulb Temperature not to exceed 155 F (68 C).
5 See page 6 and 7 for Flow Chart and how To Select Water Valve Size. 2 V47 Product Bulletin Stock Temperature Valves Optional Construction Due to many variations of Internal Bypass Temperature Actuated Valves , a group of standard V47 (open A drilled hole is provided in high) Valves are maintained in Valves which are Actuated by stock for shipment on short Temperature of Water passing notice. These Valves are through the valve. Hole in valve available in three Temperature body provides continuous ranges and are furnished with bypass flow permitting 6 feet ( m) of armored Temperature Actuated bulb to capillary and a Style 4 sense Temperature change. Temperature bulb (closed tank Eliminates requirement for immersion). All stock Valves are special bypass line. Specify supplied with a drilled and internal bypass hole size tapped internal bypass in the required. Bypass hole sizes are regulator body.
6 A solid plug is 035 in. (.89 mm), .062 in. installed in this hole for 100% ( mm), .093 in. ( mm), shutoff. A drilled plug is packed or .125 in. ( mm). (See in an envelope with each valve Fig. 4.). for field installation, if continuous minimum flow is required. (See Fig. 3.). Temperature Elements Standard Temperature elements are furnished with 6 ft ( m). capillary. Optional capillary lengths are available on quantity orders, lengths 2 ft (.6 m), 4 ft ( m), 10 ft (3 m) and longer in increments of 5 ft ( m) at extra cost. Temperature bulbs and ranges currently available are listed in Temperature Ranges and Bulb Dimension Chart. Finned air immersion type Temperature bulbs, special elements and special Temperature ranges are available. Consult Customer Service. V47 Product Bulletin 3. Stainless Steel Bulb Models with stainless bulb, support tube, and closed tank fittings are available at extra cost on special orders.
7 Mounting Bracket Mounting bracket as illustrated in Fig. 5 available on 3/8 in. valve only when specified. Specify bracket position required. Other styles of brackets on 3/8 in. and 1/2 in. Valves available on quantity orders. Consult Customer Service. 4 V47 Product Bulletin Disc Holder, Valve Seat and used specify Product No. if Extension Sleeve available. Available in monel on 3. If Product Number is not commercial Valves at additional available specify the cost. following: a. Type Number (see Capillary Protection Type Number Armored capillary tubing is Selection Chart ). available at additional cost b. Temperature range (standard on stock Valves ). required. c. Style and size of Manual Flushing Temperature element or Valves may be manually flushed bulb. by lifting range spring follower d. Length of capillary with screwdrivers at two sides of tubing. lower spring cap to open valve. This does not change valve e.
8 Fluid to be handled by adjustment. valve. Fig. 7 -- flange 4. Specify special features type Water valve (for flange Valves For Gas bolt holes). when required, such as: Temperature Actuated a. Internal bypass and Modulating Valves for regulating Repairs and Replacement diameter. flow of gas to crop driers or Field repairs must not be made b. Mounting bracket outdoor industrial equipment as except for replacement of the (3/8 in. size only) and shown in LIT-125695. sensing element, internal parts, position on valve. and the rubber diaphragms. For Companion Flanges and a replacement valve or c. Monel disc holder, replacement parts kit, contact valve seat, and Gaskets the nearest Johnson Controls extension sleeve. Kits available at additional cost, wholesaler. Replacement part d. Naval bronze valve when specified. For 1-1/2 in., kit numbers are shown in Forms body. 2 in., and 2-1/2 in. sizes -- 996-57 and 996-58.
9 125 lb. standard only. e. Armored capillary Each flange kit contains two ring tubing. Ordering Information gaskets, two cast iron flanges, f. Companion flange kit, eight machine bolts and eight When ordering Water Valves , specify Part Number. hex nuts. (See Fig. 6.) specify the following: 1. Catalog Number, if established. 5. Bulb well, by Part Number, if needed. 2. If a stock valve cannot be V47 Product Bulletin 5. To Select Water Valve Size b. Valve opening point will 5. On lower half of curve, mark be about 5F ( ) point on drawn-in horizontal Refer to Flow Chart for selection Temperature line at pressure above the valve closing of Valves . Carefully follow steps determined in Step 4. point. as outlined below. Interpolate between curves, c. Determine the or pick curve for nearest 1. Determine the maximum Temperature the valve lower pressure drop for Water flow required and is to maintain.
10 Which curve is drawn (this draw a horizontal line across upper half of Flow d. Subtract the gives a reserve maximum Chart through this flow. Temperature opening load capacity). point from the operating 6. From this point draw line 2. Determine the Temperature Temperature . This vertically upward until it rise above the valve gives the Temperature intersects drawn-in opening point. rise. horizontal Water flow line in a. Valve closing point is upper half of Flow Chart. 3. Draw horizontal line across the highest Temperature lower half of Flow Chart 7. If intersection falls on a at which it is desired to through this value. valve size curve this is the have no flow through the valve. 4. Determine the allowable valve size. pressure drop through the 8. If intersection falls between valve -- this is the pressure two curves the required actually available to force valve size is the larger of liquid through the valve.