Example: air traffic controller

VAPORMIST - dristeem-media.com

VAPORMIST Adaptable Reliable Easy to maintain Comprehensive control with the Vapor-logic controller Electric-to-Steam Humidifier2 VAPORMIST ELECTRIC HUMIDIFIERV ersatility for fi nished spacesDriSteem offers Space Distribution Units that match the VAPORMIST cabinet. See Page VAPORMIST humidifi er is a compact, cabinet-style unit compatible with all water types (tap, softened, deionized, reverse osmosis) and numerous dispersion options. Installation is a snap just attach the frame to a supporting structure and connect electrical and water services.

VAPORMIST ELECTRIC HUMIDIFIER 3 VERSATILE • Uses tap, softened, or RO/DI water • Capacity from 6 to 102 lbs/hr (2.7 to 46 kg/h), link up to 16 units for

Tags:

  Vapormist, Dristeem

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of VAPORMIST - dristeem-media.com

1 VAPORMIST Adaptable Reliable Easy to maintain Comprehensive control with the Vapor-logic controller Electric-to-Steam Humidifier2 VAPORMIST ELECTRIC HUMIDIFIERV ersatility for fi nished spacesDriSteem offers Space Distribution Units that match the VAPORMIST cabinet. See Page VAPORMIST humidifi er is a compact, cabinet-style unit compatible with all water types (tap, softened, deionized, reverse osmosis) and numerous dispersion options. Installation is a snap just attach the frame to a supporting structure and connect electrical and water services.

2 Available matching Space Distribution Units disperse steam with no visible vapor trail, making VAPORMIST ideal for use in fi nished CONTROL WITH VAPOR-LOGICV apormist with Vapor-logic sets new standards for control in electric steam humidifi cation: Interoperability allows communication with building automation systems via Modbus or with optional BACnet or LonTalk protocols. Safety presets initiate fi ll and drain cycles and keep the humidifi er cool and safe if sensed conditions, though unlikely, could be hazardous.

3 Web-enabled control allows you to set up, view, and adjust humidifi er functions via Ethernet, either directly or remotely through a ELECTRIC HUMIDIFIERVERSATILE Uses tap, softened, or RO/DI water Capacity from 6 to 102 lbs/hr ( to 46 kg/h), link up to 16 units for capacity up to 1632 lbs/hr (740 kg/h) Disperses steam through ductwork with dispersion tubes or panels, or directly into a room with a Space Distribution Unit (SDU) mounted remotely or on top of the VapormistFLEXIBLE Control to 3% RH On-off or time-proportioned (TP) control for application control in most environments.

4 Solid-state relay (SSR) option for tight control Electronically monitored water level ensures safe and reliable operationEASY TO MAINTAIN Removable cover allows easy access to evaporating chamber and electrical connections Softened water signifi cantly reduces maintenance requirements End-of-season autodrain minimizes microbial growth User-adjustable water skimmer skims off fl oating minerals Controller-operated drain and fl ush removes precipitated minerals from evaporating chamber Constant thermal

5 Expansion and contraction of heating elements continuously sheds mineral buildupVapormist features and benefi tsSAVE EVEN MORE ENERGY WITH OUR HIGH-EFFICIENCY TUBE OPTIONAn option for new and existing Ultra-sorb and Rapid-sorb dispersion assemblies, High-Effi ciency Tubes provide signifi cant energy savings: Wasted energy is reduced by up to 85%. Airstream heat gain and condensate are also signifi cantly lowered. See Page 12 for more DISPERSION: PROVEN AND GUARANTEEDWhen it comes to absorption performance, competitors don't come close to dristeem s proven and guaranteed dispersion systems.

6 Defi ne your dispersion requirements and dristeem will meet or exceed them. Guaranteed. 4 VAPORMIST ELECTRIC HUMIDIFIER Vapor-logic controllerACCURATE, RESPONSIVE CONTROLThe Vapor-logic controller provides accurate, responsive RH control. PID control tunes the system for maximum , BACnet, or LonTalk allow interoperability with multiple building automation systems. Modbus is standard, and BACnet or LonTalk are available interface provides the capability to set up, view, and adjust humidifi er functions via Ethernet, either directly or remotely through a network.

7 Cycle counter triggers a message when it s time to replace the port allows easy fi rmware updates, and data backup and restore clock allows time-stamped alarm and message tracking, and accurate drain and fl ush temperature sensor/transmitter allows air temperature monitoring, such as in a duct, and enables temperature compensation to prevent window outputs allow remote signaling and device er control allows staged control of up to 16 humidifi ers with one data, such as RH, air temperature, water use, energy use, alarms, and messages, can be downloaded to a PC for viewing and analysis.

8 RH, alarms, and messages can also be viewed on the keypad/display and Web interface. Enhanced diagnostics include: Test outputs function using keypad/display or Web interface to verify component operation Test humidifi er function using simulated demand to validate performancemc_042710_1500-VMInsert a USB fl ash drive into the Vapor-logic board s USB port to perform software updates, download data logs, and back up and restore data. KEYPAD/DISPLAYWEB INTERFACE5 VAPORMIST ELECTRIC HUMIDIFIERV apormist principle of operation1.

9 When the system is fi rst activated, the fi ll valve opens and the evaporating chamber fi lls with water to the operating On a call for humidity, the heating elements are energized, causing the water to boil. The fi ll valve opens and closes as needed to maintain the operating water During refi ll in tap/softened water systems, a portion of the surface water is skimmed off, carrying away precipitated minerals. Systems with the RO/DI water option (using deionized water or water that has been treated using reverse osmosis) do not require Steam created in the evaporating chamber fl ows through steam hose, tubing, or piping to the dispersion assembly, where it is discharged into the water VAPORMIST (shown with cover removed)OM-2000Ma2341mc_022112_0952 VAPORMIST PRINCIPLE OF OPERATION6 VAPORMIST ELECTRIC HUMIDIFIERV apormist components1.

10 VAPOR-LOGIC CONTROLLERV apor-logic controls all humidifi er functions and can connect to a building automation system via Modbus or optional BACnet or LonTalk. See Page 4 for more information. 2. WATER LEVEL CONTROLTap/softened water systems control water levels electronically using a three-rod probe, see fi gure at right. Systems with the RO/DI water option control water levels using a fl oat valve, see fi gure at right, and low-water cutoff switch. 3. DRAIND uration and frequency of draining are user adjustable.