Example: tourism industry

Vertiv Liebert CRV

Vertiv Liebert CRV. from 10 to 60 kW. Efficient Cooling for IT Equipment Vertiv Liebert CRV from 10 to 60 kW. Vertiv . Vertiv designs, builds and services mission critical technologies that enable the vital applications for data centers, communication networks, and commercial and industrial environments. We support today's growing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented by our global service network. Bringing together global reach and local knowledge, and our decades-long heritage including brands like Chloride , Liebert and NetSure , our team of experts is ready to take on your most complex challenges, creating solutions that keep your systems running and your business moving.

sensors, continuously monitors the heat load of the racks and regulates the Liebert CRV, ensuring it provides the most effective level of cooling while at the same time delivering energy savings. Variable capacity compressors modulate the cooling capacity, thus reducing input power with partial loads. EC Fan technology regulates airflow and reduces

Tags:

  Liebert, Sensor, Liebert crv

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Vertiv Liebert CRV

1 Vertiv Liebert CRV. from 10 to 60 kW. Efficient Cooling for IT Equipment Vertiv Liebert CRV from 10 to 60 kW. Vertiv . Vertiv designs, builds and services mission critical technologies that enable the vital applications for data centers, communication networks, and commercial and industrial environments. We support today's growing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented by our global service network. Bringing together global reach and local knowledge, and our decades-long heritage including brands like Chloride , Liebert and NetSure , our team of experts is ready to take on your most complex challenges, creating solutions that keep your systems running and your business moving.

2 Together, we're building the future of a world where critical technologies always work. YOUR VISION, OUR PASSION. Liebert CRV Row-Based Cooling The Liebert CRV, row-based cooling costs with maximum availability. The unit is optimized to ensure maximum Liebert CRV is a omprehensive row-based cooling capacity in a minimal footprint. solution that includes all of the main Targeted for small and medium data functions fundamental to cooling units, centers, as well as edge computing such as cooling, humidification, locations the unit provides cooling at the dehumidification, re-heating, air filtration, server rack level. condensation management, temperature and humidity control, alarm functions and The Liebert CRV has been designed to data communications.

3 Deliver the highest efficiency and availability, by removing heated air from Furthermore, the unit enhances its the data center hot aisles, using it to performances and energy efficiency return cooled air to the servers (cold through the Vertiv ICOM Control, aisle). The Liebert CRV is available in capable of optimizing unit operations by Direct Expansion, as well as Chilled Water leveraging on its intelligent management versions and in two frame widths - 600 of system components. All components mm and a compact 300 mm. Providing are easily accessible from the front and full capacity and airflow modulation to the rear of the unit, granting simplified match the servers' load, the unit is able to service intervention.

4 Deliver energy savings via its compressor The unit also allows ease of installation, with capacity modulation, Electronic through simplified cable and pipes Expansion Valve and variable speed EC. routing from top and bottom of the unit. Fans. All this leads to very low operating 10kW CRV DX. 2. Designed to Optimize IT Performance Features and Performance The Liebert CRV, row cooling unit Furthermore, Liebert CRV is designed to Thermal Management unit is ideal for comply with mission-critical requirements the cooling of data center rack rows and ensure that servers are maintained y Units ranging from 10 to 60. at the correct temperature and kW with chilled water and The Liebert CRV is a multi-option, humidity levels.

5 Direct expansion versions precision air conditioner that delivers temperature and humidity control, as well For low operational costs, the Liebert CRV y Industry's highest energy as filtration and notification management, provides the exact level of cooling saving levels achieved - required by servers, modulating the increase of up to 50% when ensuring that data center temperatures airflow and cooling capacity. the Liebert CRV is combined are maintained at an optimum level. with Vertiv SmartAisle . The unit is designed to continuously The unit is available in two versions to cold aisle containment monitor variations in heat loads and meet various installation demands: y Best-in-class Thermal instantly deliver the most efficient and y A stand-alone, direct expansion Management unit for row- effective cooling necessary.

6 System with variable capacity up to based applications Liebert CRV: Simple, Safe, Adaptable 36 kW, available in both 300 mm and 600 mm versions, complete with roof y On-site adjustment capability The Liebert CRV is a plug-and-play unit or wall-mounted condenser of air diffuser distribution with the capability of addressing the direction maximizes cooling needs of both open and contained y A chilled water system with up to 60 results applications. kW of capacity available in both 300 y Integrated Vertiv ICOM . mm and 600 mm versions. Control for management of Cooling is provided at the server rack capacity and airflow through level rather than the room level.

7 The EC Fans and variable capacity Liebert CRV removes and filters hot air Compressor from the data center aisles, using it to return cooled air to the servers. y Ideal for scalable IT. infrastructure - increased The integrated air diffusers accurately cooling capacity, reduced noise direct the airflow towards the necessary levels and enhanced efficiency direction of the heat load. when compared with similar chilled water and direct expansion configurations. 3. Vertiv Liebert CRV from 10 to 60 kW. Ensuring Availability Under All Working Conditions Maintaining IT Infrastructure Meeting Primary IT Requirements The integrated compressors with cooling Availability The Liebert CRV's ability to modulate capacity modulation are designed to avoid peaks in absorbed power, thus With integrated Vertiv ICOM Control, capacity allows for constant, accurate reducing the stress placed on the Liebert CRV is able to monitor room temperature and humidity levels to components.

8 The Liebert CRV uses a variations in temperature and humidity, be maintained. dedicated control that also enables the instantly adapting its performance to The variable capacity capability of the compressor to operate when the external meet variations in load conditions. Liebert CRV, contributes to increasing air temperature increases above This furthermore ensures increased data center availability during both standard limits. availability and safety of protected IT standard operations and in the event of equipment. load variations. The Liebert CRV's constant temperature A reduction in its start/stop cycling monitoring and control capabilities function further contributes to increasing ensure the availability of servers in all data center availability, as well as working conditions.

9 Lengthening the life of critical components. Furthermore, its parallel load sharing functionality enables the management of N+1 configurations. Extreme Flexibility for Open and Closed Architectures Suitable For a Wide Range of Installations The Ideal Airflow The Liebert CRV addresses the cooling needs of both new and existing data center EC Fans and compressors with variable space, regardless of raised floor availability. It is ideally suited to data centers with up to cooling capacity, managed through 50 racks, irrespective of heat load. integrated Vertiv ICOM Control, achieve flexible capacity and airflow for Configuration Flexibility the ideal operating conditions of IT.

10 Equipment. The Liebert CRV can be configured to perform temperature as well as humidity control. The Liebert CRV 300 mm and 600 mm width versions have been designed to The Liebert CRV, designed using specifically meet the requirements of data centers in need of optimizing space advanced, computer-aided dynamic fluid occupancy, as well as capital and running costs. technology, delivers optimum air distribution across rack installations. The exceptional levels of air distribution have been proven as a result of wide-scale laboratory and field testing. 4. Optimizing Total Cost of Ownership Delivering Optimized Results Energy Efficient Cooling Ideally suited for rack-level cooling and specifically designed for high return air The integrated Vertiv ICOM Control, temperatures, the Liebert CRV optimizes air distribution and maximizes efficiency, equipped with up to 10 rack temperature delivering both cost and energy-related savings.


Related search queries