Example: bankruptcy

VIBRATINGMESH NEBULIZER Model NE-U22V

INSTRUCTION MANUALVIBRATING MESH NEBULIZERM odelNE-U22V CAUTION: Federal law restricts this device to sale by or on the order of aphysician and/or licensed healthcare practitioner. EnglishFran aisEspa 2/18/09 3:13 PM Page 12 TABLE OF CONTENTSB efore Using the 3 Safety 4 Know Your Unit .. 7 Accessories and Replacement 8 Unit 9 Operating InstructionsBattery Installation .. 11 Using the AC Adapter .. 12 Filling the Medication 13 Selecting the Nebulization 14 Using the Device .. 15 Care and MaintenanceCleaning after Each Use .. 16 Daily 17 Caring for the 18 TroubleshootingTroubleshooting 20 Warranty 22 FCC Statement.

INSTRUCTION MANUAL VIBRATINGMESH NEBULIZER ModelNE-U22V CAUTION: Federal law restricts this device to sale by or on the order of a physician and/or licensed healthcare practitioner.

Tags:

  Manual, Instructions, Nebulizer, Vibratingmesh nebulizer, Vibratingmesh, Instruction manual vibratingmesh nebulizer

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of VIBRATINGMESH NEBULIZER Model NE-U22V

1 INSTRUCTION MANUALVIBRATING MESH NEBULIZERM odelNE-U22V CAUTION: Federal law restricts this device to sale by or on the order of aphysician and/or licensed healthcare practitioner. EnglishFran aisEspa 2/18/09 3:13 PM Page 12 TABLE OF CONTENTSB efore Using the 3 Safety 4 Know Your Unit .. 7 Accessories and Replacement 8 Unit 9 Operating InstructionsBattery Installation .. 11 Using the AC Adapter .. 12 Filling the Medication 13 Selecting the Nebulization 14 Using the Device .. 15 Care and MaintenanceCleaning after Each Use .. 16 Daily 17 Caring for the 18 TroubleshootingTroubleshooting 20 Warranty 22 FCC Statement.

2 2/18/09 3:13 PM Page 23 INTRODUCTIONT hank you for purchasing the Omron NE-U22V MICROAir Vibrating Mesh Healthcare has moved forward in the development of electronic NEBULIZER technology withthe introduction of the NE-U22V MICROAir Vibrating Mesh NEBULIZER . Focusing on patientconvenience and compliance as its goal, this device offers ultimate portability for wherever you goand revolutionary vibrating mesh technology that provides a precise, powerful and effectivetreatment every time. The MICROAir is a vibrating mesh NEBULIZER system designed to aerosolize liquid medications forinhalation by the patient.

3 The device may be used with pediatric and adult patients in the home,hospital, and sub-acute care settings. Your NE-U22V MICROAir comes with the following components: Main Unit Unit Cover Medication Bottle Mesh Cap Mask and Mouthpiece Adapter Mouthpiece Storage Case Instruction manual Instructional DVDThe following are optional accessories sold separately: AC Adapter Child MaskFill-in for future referenceDATE PURCHASED:SERIAL NUMBER:Staple your purchase receipt MICROAir is a prescription medical device. Operate this device only asinstructed by your physician and/or licensed healthcare THESE 2/18/09 3.

4 13 PM Page 34 SAFETY INFORMATIONTo assure the correct use of the product basic safety measures should always befollowed including the warnings and cautions listed in this instruction THE DEVICERead all the information in the instruction book and any other literature included in the box before using the type, dose, and regimen of medication follow the instructions of yourphysician and/or licenced healthcare is not an approved medication for use with this not use tap or mineral water in the NEBULIZER for nebulizing and disinfect the Medication Bottle, Mesh Cap, Mask, Mouthpiece and Mask and Mouthpiece Adapter before using the device for the first time after the device has not been used for a long period of time, clean and disinfectthe Medication Bottle, Mesh Cap, Mask, Mouthpiece, and Mask andMouthpiece Adapter before using dispose of any remaining medication in the medication cup after eachuse.

5 Use fresh medication each time you use the not leave the device or its parts where it will be exposed to extremetemperatures or changes in humidity, such as leaving the device in a vehicleduring warm or hot months, or where it will be exposed to direct ICONS USED IN THIS INSTRUCTION MANUALWARNINGI ndicates a potentially hazardous situation which, ifnot avoided, could result in death or serious injuryCAUTIONI ndicates a potentially hazardous situation which, ifnot avoided, may result in minor or moderate injuryto the user or patient or damage to the equipment orother 2/18/09 3:13 PM Page 45 IMPORTANT SAFETY NOTESOPERATING THE DEVICE (continued)Provide close supervision when this device is used by, on, or near infants,children or compromised the main unit and the NEBULIZER parts each time before using the sure no parts are damaged, the device is assembled properly, and thedevice operates prevent damage to the device, add the medication slowly.

6 Do not allow themedication to overflow the Medication not add more than 7 mL of medication to the medication prevent damage to the device, make sure that the Mesh Cap is correctly inplace. If the Mesh Cap is not properly closed, medication will not operate the device at temperatures greater than +104 F (+40 C).Do not subject the device or any of the components to strong shocks, such asdropping on the device is approved for human use not disassemble or attempt to repair the device or the device only as intended. Do not use the device for any other of the device, components and optional accessories according toapplicable local regulations.

7 Unlawful disposal may cause environmental only Omron authorized parts and accessories. Parts and accessories notapproved for use with the device may damage the or modifications not approved by Omron Healthcare will void theuser warranty. RISK OF ELECTRICAL SHOCK WHEN USING THE AC ADAPTERDo not plug or unplug the power cord into the electrical outlet with wet only the AC adapter designed by Omron for this device. Use of any otherAC adapter may damage the 2/18/09 3:13 PM Page 56 IMPORTANT SAFETY NOTESRISK OF ELECTRICAL SHOCK WHEN USING THE AC ADAPTER(continued)Do not overload power outlets. Plug the device into the appropriate voltage not use extension cords.

8 Plug the power cord directly into the electrical the power cord from the electrical outlet after using the the power cord from the electrical outlet before cleaning the AND STORAGEKeep the device out of the reach of unsupervised infants and children. Thedevice may contain small parts that can be not immerse the main unit in water or other not use or store the device in humid locations, such as a bathroom. Use thedevice within the operating temperature and not leave the cleaning solution in the NEBULIZER parts. Rinse the nebulizerparts with distilled water after the NEBULIZER parts after each use. Dry the parts immediately after the device and the components in a clean, safe prevent damage to the device, do not carry or leave the Medication Bottlefilled with medication or distilled not place or attempt to dry the device or any of its parts in a microwave prevent damage to the device, do not rinse or immerse the Main Unit in anyliquid, do not wash or rinse any of the parts under strong running water, and donot touch the mesh with your hand or any not use household bleach.

9 The mesh will rust and the Mesh Cap cannot be prevent damage to the device, do not clean the Main Unit using abrasivecleaners or any type of chemical, and do not allow any moisture to contact theelectrodes or the AC Adapter jack on the Main not put the AC Adapter in the Storage Case. The Storage Case is notintended to carry the AC 2/18/09 3:13 PM Page 67ON/OFF ButtonTurns the power for the Main Unit on and offBottle Cap Locking LeverOpens the Medication Bottle for cleaning Medication BottleHolds maximum capacity of 7mL for treatmentMedication PortAdd the medicine to the bottle ElectrodePower conductor from the Main Unitto the vibrator on the MedicationBottleBattery Low IndicatorAn orange light blinks when thebatteries are wornPower IndicatorThe green light shows the power is onMain UnitBottom of Main UnitBattery CoverPush lever to remove coverMedicine BottleMesh CapMetal Alloy Mesh createshigh efficiency aerosolMask and Mouthpiece

10 AdapterMouthpieceMain Unit Cover Protects the MainUnit with theattachedMedication Bottleand Mesh Capduring storageHolds the Mouthpiece or Masksecurely on the devicePatient InterfaceKNOW YOUR UNITE lectrodePower conductor from the MainUnit to the AC AdapterConnection 2/19/09 2:37 PM Page 78 KNOW YOUR UNITI nstruction ManualStorage CaseInstructional DVDP ower PlugCord BandAC Adapter Connection StandCase holds the Main Unit,Medication Bottle, Mask andMouthpiece AdapterAC Adapter Model No. U22-5 Optional AccessoryOptional AccessoryReplacement PartsModel COVERU22-8 MAIN UNIT COVERU22-9 MASK AND MOUTHPIECEADAPTERU22-2 MEDICATION BOTTLEU22-3 MESH CAPU22-4 MOUTHPIECEU22-1 STORAGE CASE U22-7 Child MaskModel No.


Related search queries