Transcription of Volumetric KF Titrator
1 Volumetric KF TitratorV10S/V20S/V30 SUser Manual30297193C 7/18/2017 12:15 PM - Schema ST4 PDF engine - Layout by Victor MahlerVolumetric KF TitratorTable of Contents1 Introduction32 Safety of signal words and warning safety and rear panel of the the the Titrator to the power the Titrator from the power titration stand and titration positions for sensors, tubes and the measuring and connect a the burette to the titration the waste the solvent manager to the the waste bottle to the tiration the solvent the solvent the up the Titrator and shut down the a Volumetric Karl Fischer and filling the the titration the Volumetric KF the a direct the the an the titrator227 Care and KF Titrator8 Disposal239 Technical data232 Volumetric KF Titrator1 IntroductionThank you for choosing a METTLER TOLEDO Volumetric KF Titrator .
2 The Volumetric KF Titrator is an easy-to-operate instrument for Volumetric Karl Fischer this documentThis document provides you with the information you need to get started with your METTLER TOLEDO a comprehensive description of the instrument and its functions, refer to the OperatingInstructions, supplied as PDF file on the instructions in this document refer to titrators running firmware version or you have any additional questions, contact your authorized METTLER TOLEDO dealer or service and symbolsRefers to an external useful information about the of instructions Intermediate results Results3 Volumetric KF Titrator2 Safety information Read and understand the information in this User Manual before you use the instrument. Keep this User Manual for future reference. Include this User Manual if you pass on the instrument to other the instrument is not used according to the information in the Operating Instructions or if it is modified, thesafety of the instrument may be impaired and Mettler-Toledo GmbH assumes no a comprehensive description of the instrument and its functions, refer to the OperatingInstructions, supplied as PDF file on the of signal words and warning symbolsSafety notes are marked with signal words and warning symbols.
3 These show safety issues and the safety notes may lead to personal injury, damage to the instrument, malfunctions and wordsWARNINGfor a hazardous situation with medium risk, possibly resulting in death or severeinjury if not a hazardous situation with low risk, resulting in damage to the instrument, othermaterial damage, malfunctions and erroneous results, or loss of symbolsElectrical safety notesIntended useThis instrument is designed to be used in laboratories by trained staff. The instrument is suitable for theprocessing of reagents and other type of use and operation beyond the limits of technical specifications without written consent fromMettler-Toledo GmbH is considered as not of the instrument ownerThe instrument owner is the person that uses the instrument for commercial use or places the instrument atthe disposal of the staff.
4 The instrument owner is responsible for product safety and the safety of staff, usersand third TOLEDO assume that the instrument owner provides the necessary protective gear , appropriatetraining for the daily work and for dealing with potential hazards in their notes WARNINGD anger of death or serious injury due to electric shock!Contact with parts that contain a live current can lead to injury and use a METTLER TOLEDO power cable and AC adapter designed for your the power cable to a grounded power all electrical cables and connections away from damaged power cables and AC adapters KF TitratorNOTICED anger of damaging the touch screen with pointed or sharp objects!Pressing on the touch screen with pointed or sharp objects may damage it. Operate the touch screen by applying gentle pressure with the pad of your of damage to the instrument due to incorrect parts!
5 Using incorrect parts with the instrument can damage the Instrument or cause the instrumentto malfunction. Only use parts supplied with the instrument, listed accessories and spare parts fromMETTLER KF Titrator3 Design and bottle drying tube10 Power button2 Solvent bottle drying tube11 Indicator light (LED)3 Waste bottle drying tube12 Touchscreen4 Solvent manager13 Burette drive5 Waste bottle14 Burette arrestment knob6 Solvent bottle15 Burette 5 mL7 Titration arm16 Drying tube for the titration beaker8 Titration beaker17 Double platinum pin electrode9 Internal magnetic stirrer18 Titrant bottle6 Volumetric KF buttonAccesses the interactive online help for the content of the current screenDisplays information and can be used to enter buttonReturns you to the home screen from any menu buttonEnds all tasks that are currently rear panel connectionsSocketUseExampleSTIRRER pumps tirrer/pumpSolvent manager/stirrerSENSORM easuring electrodeDM143-SCTTL-I/OSample changer/homogenizerStromboli/homogenizer via TBoxPOWER SUPPLYAC adapterAC adapterCOMB alanceXS analytical balanceETHERNETN etworkLink to LabX PC software via networkPCPC
6 Connection via USBLink to LabX PC software via USBinterfaceUSB 1 Printer/barcode reader/memory stick/USB hub/sample changerUSB-P25 compact printer/InMotion KFUSB 2 Printer/barcode reader/memory stick/USB hub/sample changerBarcode reader/InMotion KFCAN OUTCAN connectionFor service use7 Volumetric KF screen541236789 HomeMethodsSeriestemplatesResultsSetupMa nualTasksStartUser dataLog outNameExplanation1 Shortcut areaShows indirect and direct shortcuts for frequently used methods. Shortcuts aresaved in the user profile and can be defined, changed and deleted by the shortcutAn indirect shortcut opens the window Start analysis of the shortcutA direct shortcut starts the method without opening the window Start barThe status bar contains the current menu item, user name as well as date statusShows the current working status of the measurement runningGreenMeasurement running6 StartSwitch to direct measurement (quick start for the defined standardmeasurement of this instrument).
7 7 User dataOpens a window with information about the currently logged in outDirectly log out the current user. The window Login opens after logging and handle methods for every measurement templatesOpen the menu for series templates for every method available on all measurement results, print out or export them. Visit detail infor-mation about every single all system settings in this menu, ,, hardware settings, usermanagement or user preferences. These settings are usually made duringinstallation of the the manual operations available on the KF keypadNumeric keypadCancelPreviewOKMethod ID412356 CancelOKEnter auxiliary value12 Tap (1) to see how your input looks like. Tap (2) for capital letters. Tap (3) for lowercase letters. Tap (4) to switch to a numeric keypad and(2) to turn back to alphanumeric. Tap (5) to delete all entered letters ornumbers.
8 Tap (6) to delete the last entered letter ornumber. Tap (1) to delete all entered numbers. Tap (2) to delete the last entered StructureMethodsThe menu Methods has no templatesThe menu Series templates has no menu Results has the following submenus. All resultsStatistics Samples Add result Recalculate Undo allMenu level 2 Menu level 3 ChemicalsTitrantsConcentration standardsUser settingsLanguageScreenAudio signalShortcutsKeyboardValues (only V30S)Blanks (only V30S)Auxiliary values (only V30S)9 Volumetric KF TitratorMenu level 2 Menu level 3 HardwareSensorsPumpsPeripheralsTitration StandsHomogenizersGlobal settingsSystemUser managementAnalysis and resources behaviorSolvent Control (only V30S)Mainten. & ServiceMT-ServiceImport / ExportReset to factory settingsTitrator firmware historyBoard firmwareTerminalBoard dataDrivesBurettesUpdateDelete Mettler method template (only V30S)ManualThe menu Manual has the following submenus.
9 Stirrer Sensor Burette Pump4 InstallationStandard equipment for the Titrator types varies. For this reason, installation steps may of deliveryPartOrder numberV10SV20SV30 SVolumetric KF Titrator External power supply( V) Power cable (country-specific) 10 Volumetric KF TitratorPartOrder numberV10SV20SV30 SProtective cover for touchscreen51105567 Titration vessel51107463 Cover plate for Volumetric titrationvessel51107462 Threaded ring51107459 O-ring51190366 Fastening screw (for titration vessel)51107474 Three-hole adapter23943 NS stopper23452 NS 10 stopper23836 Pin-hole stopper Connector KF Titrators23957 Magnetic stirrer bar51191159 Interchangeable burette set, 5 mL51107500 Silicone tube, 133 mm Drying tube holder23915 11 Volumetric KF TitratorPartOrder numberV10SV20SV30 SDrying tube with cover (3 pcs) Seal (titration stand drying tube)51107492 Solvent Manager set with.
10 Silicone tube, 850 mm Silicone tube, 170 mm Drying tube with cover Flat seals (2 pcs.)51105600 Clear glass bottle, 1 L30079610 Flat seals (2 pcs.) Screw top (for bottles)23937 2 Draining tubes / dispensing tubes51107481 Adapter for immediate draining51105594 Dual platinum pin electrode,DM143-SC51107699 Triaxial SC LEMO cable, 70 cm89601 Glass wool (2 g)51108143 Molecular sieve, 250 g71478 CD Titration User Documentation30297239 User Manual 12 Volumetric KF TitratorPartOrder numberV10SV20SV30 SMemo Card Test report EC declaration of conformity the titrator1 Remove the Titrator (and accessories) from the protective packing the packing material for later transport over long if you received all parts listed in the scope of the parts visually for flaws or parts are missing or damaged, report it immediately and file a freight claim if the titratorThe instrument has been developed for indoor operation in a well-ventilated area.