VULCRAFT® LEGACY ROOF DECK DIAPHRAGM TABLES
Design Manual, Third Edition” (DDM03) in accordance with the 2015 IBC. ROOF DECK Historically, published diaphragm design tables for roof deck have been based on diaphragm shear loads only. These historical tables have not considered the condition of wind uplift in conjunction with diaphragm shear due to wind loads.
Tags:
Design, Table, Roof, Deck, Diaphragm, Legacy, Legacy roof deck diaphragm tables, Design tables
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
1.5VL-36/1.5VLI-36/1.5PLVLI-36 COMPOSITE DECKS GRADE …
vulcraft.comGRADE 50 STEEL ASD 1.5VL COMPOSITE DECKS WWW.VULCRAFT.COM • ASTM A653 SS GR50 Min., with G60 or G90, white or gray primer bottom optional • ASTM A1008 SS GR50 Min. with gray primer bottom • Standard lengths – 6’-0” to 42’-0” • IAPMO UES ER-0652 and UL Listed • Tables conform to ANSI/SDI C-2017
2VLI-36/2VLJ-36/2PLVLI-36 COMPOSITE DECKS GRADE 50 …
vulcraft.com2. See Composite Deck-Slab Strength Web Based Solutions for alternate slabs or LRFD design. Note: 1. Maximum unshored spans do not consider web-crippling. Required bearing should be determined based on specific span conditions. Superimposed Allowable Load, W n /Ω, Limited by L/360 (psf) NWC (145 pcf), f’ c = 3000 psi Total Slab Depth Deck ...
Understanding steel joists - Vulcraft
vulcraft.comLighter weight joists translate into potentially lighter weight columns and reduced foundation costs. • Live-load deflections are significantly reduced due to composite …
Understanding, Steel, Composite, Columns, Joists, Understanding steel joists
1.5B-36/1.5BI-36/1.5PLB-36 ROOF DECKS GRADE 50 STEEL ASD
vulcraft.comGRADE 50 STEEL ASD 1.5B ROOF DECKS WWW.VULCRAFT.COM • 1.5B-36 Deck used with Side-lap Screws • 1.5BI-36 Deck used with TSWs or BPs • 1.5PLB-36 Deck used with PunchLok® II System Section Properties Deck Gage Deck Weight Base Metal Thickness Yield Strength Effective Moment of Inertia at Service Load I d = (2I e +I g)/3 Effective Section ...
2VLI-36/2VLJ-36/2PLVLI-36 COMPOSITE DECKS LRFD …
vulcraft.com22 6'-10" 7'-10" 8'-1" 56.0 10.32 5.15 5.73 20 8'-2" 9'-0" 9'-4" 56.3 11.00 6.13 6.79 19 9'-0" 10'-1" 10'-5" 56.6 11.60 7.03 7.00 18 9'-4" 11'-0" 11'-4" 56.9 12.14 7.86 7.00 16 10'-1" 12'-6" 12'-1" 57.6 13.25 9.62 7.00 6½” 4½” 22 6'-5" 7'-3" 7'-6" 68.1 16.78 6.55 6.64 20 7'-7" 8'-4" 8'-8" 68.4 17.83 7.82 7.70 19 8'-5" 9'-4" 9'-8" 68.7 18 ...
Deck, Composite, 2vlj 36 2plvli 36 composite decks, 2vlj, 2plvli
3VLI-36/3VLJ-36/3PLVLI-36 COMPOSITE DECKS GRADE 50 …
vulcraft.com2. Dramix® fibers may be used in UL or ULC fire rated assemblies in lieu of WWR. See UL file R19307 for additional information. For information on Bekaert Dramix® fibers contact 770-514-2295 or [email protected].
Related documents
Chapter 2 Design for Shear - Engineering
by.genie.uottawa.caThe compressive strut capacity of concrete is reached if Vn/(bwd) = 10.0√fc’. Additional stirrups cannot increase section shear strength, as the concrete strength is considered exhausted when Vn/(bwd) > 10√fc’. Design aid SHEAR 2 consists of 3 tables that may be used to determine shear capacity …
Chapter 11: Design
wisconsindot.govChapter 11: Design FACILITIES DEVELOPMENT MANUAL . Wisconsin Department of Transportation . Section 11-1 Introduction . ... Superelevation Tables (emax = 4% and 6%) ... Factors Used for Highway Capacity Manual LOS Thresholds
Design Wind Pressure Tables - Boise Cascade
ecatalog.bc.comanchorages established by Architectural Testing report 99242.06-122-34. If a calculated design pressure capacity is greater than the calculated design pressure for a particular installation, the installation is deemed acceptable. Summary tables are presented on page 8 through page 15.
LRFD Beam Load Tables - cousesteel.com
www.cousesteel.comTables are presented for two specified minimum yield point steels; Fy = 46 ksi and Fy = 50 ksi. The tabulated factored uniform loads for HSS sizes produced by the ERW and SAW methods are presented in separate tables. The factored uniform loads, in kips, are based upon the flexural design strength specified in the "HSS Specification". Factored
7. Seismic Design - University of Nebraska–Lincoln
se.unl.edu11) To determine the 5% damped of critical design spectral response accelerations, denoted as _____ at short and long periods, respectively; the following equations from IBC 1613.3.4 can be utilized (using Tables 2 and 3): 12) The design earthquake event considers an approximate return period of _____
KEYSTONE DESIGN MANUAL Unit Design Keywall Appedix ...
www.keystonewalls.comdesign manual recognizes the many technical nuances of segmental retaining wall design and provides needed criteria for proper engineering and design evaluation of modular systems. The more conservative AASHTO design standards remain the published standard for the transportation sector and cover many of the major structures constructed to date.
DESIGN GUIDE AL #1 BRIDGES FOR LIVESTOCK AND …
efotg.sc.egov.usda.govextending the bearing pads to a soil layer having adequate bearing capacity. See Department of the Navy Design Manual, NAVFAC DM-7, March 1971, Table 11-1 for typical bearing capacity values of various soils. In order for the bearing pads to function properly, several things must be considered when siting the bridge location.