Example: air traffic controller

W series Catalog - Kuroda Pneumatics Ltd.

-1-INDEXS ucceeding the transmission systemSucceeding the transmission system of H series , W series raises theof H series , W series raises thefollowing functions as functions as specification is 256 points of a Self-lifting screw Terminal input terminal unit without derating and PTW configuration makes it connectableup to 50 series can be operated together withthe old H : The old H series will be obsoleted when the stock is running out. The new W series can take over basic units of H UnitMaster Unit > Uni-Connector, Send Unit, End Unit > Interface Unit > GatewaySlave UnitSlave Unit > Terminal block type > Relay Output Terminal > Compact Terminal > Analog Unit > Mini Terminal > Module > UNI-WIRE buffer fo Torolley Duct devices > Terminal Unit for Spatter-proof specificationPueumatic UnitPueumatic Unit > UW-A05E/A12E series ---UNI-WIRE Manifold > UW-K20 series ---UNI-WIRE Manifold > Rotary JointAuxiliary UnitAuxiliary Uni

Master UnitMaster Unit Uni-Coneector, Send Unit, End Unit Send Cable 24V 0V PLC R T R T R T R T SET DISPLAY SEND UNIT SDW-H2 UNIT ADDRESS UNITS MONITOR ON-LINE 24V Xc FGD

Tags:

  Series, Catalog, W series catalog, R t r t r t r t

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of W series Catalog - Kuroda Pneumatics Ltd.

1 -1-INDEXS ucceeding the transmission systemSucceeding the transmission system of H series , W series raises theof H series , W series raises thefollowing functions as functions as specification is 256 points of a Self-lifting screw Terminal input terminal unit without derating and PTW configuration makes it connectableup to 50 series can be operated together withthe old H : The old H series will be obsoleted when the stock is running out. The new W series can take over basic units of H UnitMaster Unit > Uni-Connector, Send Unit, End Unit > Interface Unit > GatewaySlave UnitSlave Unit > Terminal block type > Relay Output Terminal > Compact Terminal > Analog Unit > Mini Terminal > Module > UNI-WIRE buffer fo Torolley Duct devices > Terminal Unit for Spatter-proof specificationPueumatic UnitPueumatic Unit > UW-A05E/A12E series ---UNI-WIRE Manifold > UW-K20 series ---UNI-WIRE Manifold > Rotary JointAuxiliary UnitAuxiliary Unit > Adaputer > Parts for Connection > Loop wiring disconnection detection unitOPERATIONOPERATION566777888889910111 11112 UNI-WIRE hasbeenrenewedfromHtoWseriesUNI-WIRE hasbeenrenewedfromHtoWseriesSPECIFICATIO NUNI-WIRE SYSTEM Structure

2 And H-featureThe UNI-WIRE SYSTEM is a highly reliable wire saving system. Data trasnsmission is performed using two signal wires (D and G), and the system uses a simple concept and structure which makes long-distance data transmission possible. The"H-feature" has disconnection detection function point indicator function that further enhances the safety and flexibility of the UNI-WIRE numbers of the Terminal Units that the Send Unit has detected as being disconnected can be displayed on Send Unit (under MONITOR). Press the DISPLAY switch to step through the ID numbers of the Terminal Units that did not send a response to the Send detect the disconnection in transmission lines, the UNI-WIRE SYSTEM exchanges the ID numbers between the Control Unit and the respective Terminal Units on the transmission line, and continually moni-tors whether transmission is successful.

3 > Detection of abnormal conditions at each terminal (each Terminal Unit) is possible.> Each Terminal Unit has its own ID number and the location of abnormal codition (such as disconnection) is indicated by the ID number.> Disconnection detection is possible even when there are branches in the transmission line.> Units without the H-feature may be used in a UNI-WIRE SYSTEM that has the H function (by connect-ing the End Unit ED-H2)Features of the UNI-WIRE H-featureMethod of abnormal condition detection by H-featureSend Unit displayAbnormal IDnumber indicationMONITORMONITORMONITORN umber of connected Units [ON-LINE]Error indication[ER1,ER2,ER3,ER4,ER5]Send UnitSDW-H2 SDW-H2 DISPLAYS witchSETDISPLAYSEND UNITSDW-H2 UNIT ADDRESSUNITSMONITORON-LINE24 VXcFGD0 VXaG0 VER1ER2ER3ER4ER5 RUNSENDSIZEPOW3264128 256 Monitor indication [MONITOR]> The Send Unit (controller side) sends the ID num-bers to the Terminal Units (terminal side).

4 > When a Terminal Unit receives the ID number that matches its own ID, it sends back a confirmation response to the Send Unit.> If the Send Unit does not receive a confirmaion response for an ID number, it judges the that the corresponding Terminal Unit is UnitSETDISPLAYSEND UNITSDW-H2 UNIT ADDRESSUNITSMONITORON-LINE24 VXcFGD0 VXaG0 VER1ER2ER3ER4ER5 RUNSENDSIZEPOW3264128 256 TerminalTerminalUnitUnitTerminalTerminal UnitUnitTerminalTerminalUnitUnitTerminal TerminalUnitUnitTerminalTerminalUnitUnit TerminalTerminalUnitUnitTerminalTerminal UnitUnitTerminalTerminalUnitUnitTerminal TerminalUnitUnitTerminalTerminalUnitUnit -2--3-SPECIFICATIONS election SpecificationsThe UNI-WIRE SYSTEM has wide range of specification selections to ensure suitability to a wide range of applications.

5 These include the H-feature, number of I/O points, and maximum transmission distance. Refer to the list below for in UNI-WIRE Terminal Units by H-featureUnits with H-featureAvailableAvailableAvailable for theTerminal Units W typeIf a control unit with the H-feature( SDW-H2) is used, detection of dis- connection position is without H-featureNot AvailableNot AvailableNot Availablefor 120 seriesUnits for general purpose---------This mark indicates the unitswhich can be used regardless of H-feature availability. Difference of specification in UNI-WIRE Terminal Units by points/distanceBasic(C-spec*) (S-spec*) (Z12-spec*) specifications are all specifications can be of the following cases may be selected : I/O: 128 points/ 256 points.

6 Distance:200m/500m/1kmBasic specification is possible but please contact us regarding of selection of other purposeThis mark indicates that the unit can be used for any specification without model : The terminal unit of different specification on one transmission line is not specification of mark * serve as 128-point correspondence of series of H-featurePoint / Distance Selection (maximum points / maximum distance)Specifications SpecificationBidirectional time-division multiplexBit synchronizationUNI-WIRE protocolMulti-drop for each Terminal UnitMax. 20 Terminal Units(STW and PTW configuration makes it connectable up to 50 terminals) (Basic with H-feature) (Basic without H-feature)200m max.

7 For each Terminal Unit ItemTransmission methodSynchronization methodTransmission protocolConnection methodNumbers of connectionsTransmission speedTransmission cable lengthGeneral specificationsTransmission specification SpecificationDC 24V -10% to +15%0 to +50 degrees Celsius-20 to +70 degrees Celsius35 to 85%RH No dewingVoid of conductive dust and corrosive gasesJIS C 0040100m/s2 (10G)20 Mor more between terminal and frame1000V ACfor 1 minute between terminal and frame1200V p-p (1 s pulse width) ItemSupply voltageAmbient temperatureStorage temperatureAmbient humidityAtmosphereVibration resistanceShock resistanceInsurance resistanceWithstand VoltageNoise immunityTransmission delayTransmission distancePoints326496128256 Transmission delay (ms) : with - - - - - - - - - - - - - - - : The above figures are given in the construction of SD-120 and.

8 The mark shows the delay time of basic models (basic specification)Selection symbolin this catalogSpecificationI/O pointsTransmission distance (m)Transmission speed (kbps) ItemDetection of the disconnection on branch linesIndication of the point of disconnectionDetection of power failure at Terminal UnitsH-feature symbol in this Catalog -4-Model No. Representation when orderingUNI-WIRE Terminal UnitsCommon Terminal UnitsSymbol of specification of representation of Model 16T-Z58 STW-H 16T-Z58 PTW- PTW- 0808T- MT- MBasic typeCommon specificationModel cassificationSpecification classification1)Classification by points/distance (see the table below)2)Users individual specification (described as -Z[ ][ ])[Basic model classification]H=with H-feacher(no mark)=without H-feacher/general purpose[Model classification in Basic model]NOTE) There are exceptions in some models.

9 > Symbol of specification classification by points / distanceSPECIFICATIONM aster UnitMaster Unit Uni-Coneector, Send Unit, End UnitSend Cable24V0 VPLCRTRTRTRTSETDISPLAYSEND UNITSDW-H2 UNIT ADDRESSUNITSMONITORON-LINE24 VXcFGD0 VXaG0 VER1ER2ER3ER4ER5 RUNSENDSIZEPOW3264128 256 Uni-ConeectorUni-ConeectorCableEnd ConnectorSend UnitSend CableEnd UnitInput Uni-connector 32 pointOutput Uni-connector 32 pointUni-connecotor Cable 7 cmUni-connecotor Cable 15 cmUni-connecotor Cable 25 cmEnd Connector for Uni-connecotorUCW-32 SUCW-32 PCND-05-07 CND-05-15 CND-05-25CN-EDUCW-32 SUCW-32 PCND-05-07 CND-05-15 CND-05-25CN-EDSend Unit (with H-feature)1m(for SDW-H2 Send Unit)2m(for SDW-H2 Send Unit)

10 End UnitSDW-H2 HKCN-05-1 KHKCN-05-2K--------------------ED-120 SpecificationNameModel No. of W series (with H-feature)Model No. of 120 series (without H-feature) Dimention(W D H mm)10<Connectable PLC Makers and Models> > Uni-connector Basic Model No.<Example of System Configuration>UCW-32S[ ][ ] : Input Uni-connectorUCW-32P[ ][ ] : Output Uni-connector([ ][ ] means the symbols designating connectable PLC)<Connectable PLC>Symbol[ ][ ]PLC MakersPLC input unitPLC output unitC500-OD213C200H-OD218C200H-OD219 CQM1-OD213C500-ID219C200H-ID216C200H-ID2 17 CQM1-ID213AX42,AH42(X side)A1SX41A1SX42A1SH42(F side)AY42,AH42 (Y side)A1SY41A1SY42A1SH42 (L side)MitsubisiElectric (ST-5)*1ST-7(ST-5)*1 MIOXLWide use PLC24V input module*2(for cable wire)24 Voutput module*2(for cable wire)CA*1 Use Uni-connector adapter UA-XL(ref.)