Water chillers Heat pumps - EUROCONFORT

AQUACIAT POWERW ater chillersHeat pumps1 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - heat EXCHANGE - NA BCooling capacity:330 to 500 kWHeating capacity:340 to 500 kWHigh energy efficiency with R410 ACompact and quietScroll compressorsBrazed-plate heat exchangersSelf-adjusting electronic controlTotal andpartialheat recoveryCoolingonlyHeat pumpHydraulicmoduleUSEAQUACIAT powerLD - LDC - LDHand ILD - ILDC - ILDH seriespackaged chilled Water or hot Water production units aremedium-capacity machines specifically designed for heatingand air-conditioning applications in one office healthcare,industries administration shopping centres and packaged units are specifically designed for outdoorinstallation and require no special protection from use the outdoor air as the sole transfer medium, whichpermits the evacuation of heat in summer or the supply ofthermal energy for heating in connected to a radiant floor heating and cooling system.

AQUACIAT POWER Water chillers Heat pumps AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.621 B 3 MAIN COMPONENTS Hermetic scroll compressors

Tags:

  Pumps, Water, Heat, Chiller, Scroll, Water chillers heat pumps

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Water chillers Heat pumps - EUROCONFORT

1 AQUACIAT POWERW ater chillersHeat pumps1 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - heat EXCHANGE - NA BCooling capacity:330 to 500 kWHeating capacity:340 to 500 kWHigh energy efficiency with R410 ACompact and quietScroll compressorsBrazed-plate heat exchangersSelf-adjusting electronic controlTotal andpartialheat recoveryCoolingonlyHeat pumpHydraulicmoduleUSEAQUACIAT powerLD - LDC - LDHand ILD - ILDC - ILDH seriespackaged chilled Water or hot Water production units aremedium-capacity machines specifically designed for heatingand air-conditioning applications in one office healthcare,industries administration shopping centres and packaged units are specifically designed for outdoorinstallation and require no special protection from use the outdoor air as the sole transfer medium, whichpermits the evacuation of heat in summer or the supply ofthermal energy for heating in connected to a radiant floor heating and cooling system.

2 Fan coil units or an air handling unit, the ILD - ILDC - ILDH seriesof reversibleAQUACIAT powerunits makes heatingand air conditioning buildings extremely unit is delivered fully assembled, wired (control andpower), charged with refrigerant and factory make the necessary electrical and hydraulicconnections, and your unit is ready to seriesCooling-only version without hydraulic - LDH seriesCooling-only version with hydraulic system (circulator pumponly or pump and buffer tank).AQUACIAT powerILD seriesAir-to- Water reversible heat pumps without hydraulic - ILDH seriesAir-to- Water reversible heat pumps with hydraulic system(circulator pump only or pump and buffer tank).HFC R410 AENVIRONMENTALLYFRIENDLYPROTECTIONDEL'EN VIRONNEMENTAIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - heat EXCHANGE - NA BAQUACIAT POWER2 Water chillersHeat pumpsDESCRIPTIONEach AQUACIAT powerLD - LDC - LDH series cooling-only unit ILD - ILDC - ILDH reversible heat pumpis delivered withthe following components:- air-cooled condenser with axial fan motor assembly,- chilled- Water evaporator (hot- Water condenser on reversible models),- chilled- Water or hot- Water capacity control,- control, automatic operation and startup box.

3 Electrical power supply: Three-phase AC - 50 Hz - 400 V (+6% / -10%) + Earth. Control circuit: Single-phase AC - 50 Hz - 230 V(transformers fitted on unit as standard),- casing for outdoor installation. Compliance with European directives- Machinery directive (98/37/EEC)- EMC directive (2004/108/EC)- Low voltage 2006/95/EC- Pressure equipment directive (97/23/EEC, category 2). Compliance with standards- EN 60204, EN 378-2 (NFC 15-100, France).KEYILD> heat pump versionH>hydraulic with pump and buffer tankLD>cooling-only version1800>unit sizeC>hydraulic with pump onlyV>R410A refrigerantLDC - ILDC 1200 V - 1500 V ModelsAQUACIAT POWERW ater chillersHeat pumps3 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - heat EXCHANGE - NA BMAIN COMPONENTS Hermetic scroll compressors- Built-in electric motor cooled by suction gas- Motor protected by internal winding thermostat- Placed on anti-vibration mounts.

4 Evaporator- Brazed-plate heat exchangers- AISI 316 stainless steel plates- High-performance, optimised plate patterns- Thermal insulation. Condenser- High-performance air-cooled exchangers, aluminium fins withoptimised profiles and grooved copper tubes- Condenser or evaporator mode heat exchanger on ILD-ILDC-ILDH reversible heat pumps - Axial fans with profiled blades- IP54, class F motors. Control functions or safety devices- Water flow control- Thermostatic expansion valves- Refrigerant high and low-pressure safety devices- Temperature and pressure sensors- Evaporator Water flow controller- Unit start-up sequence. Electrical boxThe fully wired electrical box housing all the electricalcomponents and the electronic CPU board controls the entireunit, monitors its operation, adjusts Water setpoints andinterfaces with an external control features:- Control and power circuits,- Wire numbers,- Main safety switch with handle on front,- Control circuit transformer,- Circuit breakers on the power and control circuits,- Compressor motor contactors,- Fan motor contactors,- Main earth connection,- Connectmicroprocessor-controlled electronic control unit,- Alarm or information signals on free terminals.

5 Casing- Removable galvanised metal panels,- RAL 7024 and RAL 7035 lacquer CONTROL UNITCIAT electronic control module with microprocessor and CPU,with central automatic operation and access to internaloperation states. Features- On, off, reset or remote control- Cooling or Heating mode selector- RS485 output for BMS connection- Board adapter for additional dry contacts (option)- Remote-control adapter (option)- Multilingual analogue LCD and LEDs Functions- Operation information displayed via:. Multilingual clear-text messages. Direct temperature and pressure readings- Complete management of compressors with start-upsequence, timer and runtime balancing- Self-adjusting and proactive functions with adjustment ofsettings drift control- Cascade stage system on multiple compressors lowerspower based on cooling and heating demands controlled usingthe Water temperatures- Monitoring of internal operation parameters- Second setpoint management- Direct display of Water and pressure temperatures- Operating status and fault analysis.

6 HP/LP, Water flow, compressor motors, frost protection- Short-cycle protection- Remote management and remote monitoringAIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - heat EXCHANGE - NA BAQUACIAT POWER4 Water chillersHeat pumpsAQUACIAT powerLDLDC-LDHILDILDC - ILDHCOOLING ONLYHEAT PUMP400 V/3-ph/50 Hz + Earth with transformer Main disconnect switch Water flow switch Electrical cabinet wire numbers All-season operation (-15 C outdoor minimum) Optimised High Pressure Operation(All-season operation with energy optimisation) --LOW NOISE version XTRA LOW NOISE version Compressor suction shut-off valves Soft start Fan speed control (-20 C outdoor minimum) Electronic expansion valve --Frost protection Phase controller (reversal, loss, over and under voltage) Partial heat recovery - Desuperheater Total heat recovery Blygold coated coil Polyurethane coated coil fins Single or double pump (C and H version)- - Low-temperature glycol/ Water mix (0 C to -12 C) (1) 800 micron Water filter Elastic suspensions Flexible hydraulic couplings Remote control unit (remote control panel) Dry-contact relay board LonWorks gateway Multiconnect multi-unit management Auxiliary electric heating management board (4 stages)-- Container handling equipment Shackles Note: Some technical options not listed above may be added on special request.

7 Consult OROPTIONALEQUIPMENT Supplied as standard Factory-fitted option Option supplied as a kit-Not available(1) Supplied as standard for a glycol / Water outlet temperature of 0 C to -12 CAIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - heat EXCHANGE - NA BAQUACIAT POWER8 Water chillersHeat pumpsAQUACIAT power LD - LDC - LDH1200 V1500 V1650 V1800 VCooling capacity kW334380438493 Power / / / / / Lp (high-performance [HP] version)dB(A)93 / 6195 / 6396 / 6498 / 66Lw / Lp (Low Noise [LN] version)dB(A)91 / 5990 / 5891 / 5991 / 59Lw / Lp (XTRA Low Noise [XLN])dB(A)87 / 5587 / 5587 / 5588 / 56 CompressorHermetic scroll (2900 rpm)Start-up modeDirect inline cascadeQuantity46 Power controlNo. of stages4686% oil typePolyol ester Kow 3 MAF (32 cSt)Oil of refrigerant lines2 Refrigerant (GWP)R410A (1720)Refrigerant chargeCircuit 1kg26343240 Circuit 2kg28343446 Electrical power supplyph/Hz/VThree-phase AC - 50 Hz - 400 V (+6% / -10%) + EarthMachine protection ratingIP44 Control circuit voltageph/Hz/VSingle-phase AC - 50 Hz - 230 V (+6% / -10%) - transformer fittedEvaporatorBrazed-plate heat exchangersWater Water outlet temp.

8 ( ) C-12 / +18 Minimum Water flow ratem3/h38435056 Maximum Water flow ratem3/h106110110110 Water DN 125 Max. pressure, Water endbar10 bar (LOD)/4 bar (LDC-LDH)Air-cooled condenserFinned heat exchangerFan x Motor output, high-performance (HP) version kW6 x x x Motor rated power High Performanceseries - LN - and Xtra Low Noise - XLNkW6 x x flow, high-performance (HP) versionm3/h121800117000159200156000 Air flow, low noise (LN) version andXTRA Low noise ( XLN) versionm3/h9000087600118400116800 Minimum system Water volumel11718719051133 Tank volume, model Hl950 Expansion vessel, C & Hl50 (C version) - 80 (H version) on selection(page 10)Height (excluding mounts)mm2200 ( 2450 Xtra Low Noise version)Length (standard version)mm42605626 Length (version C)mm42605626 Length (version H)mm52896655 Widthmm2200 Weight (empty, standard version)kg3499395745674621 Weight (empty, version C)kg3859433249344988 Weight (empty, version H)

9 Kg4404487054795532 Storage temperature C+50 High-performance version capacities based on: EN 14511 Eurovent conditionsCOOLING: +12 C / +7 C and condenser air inlet temperature of +35 C Gross EER and ESEER values Overall sound power level (Lw) overall sound pressure level (Lp) measured at 10 metres in a free field, as per ISO 3744 TECHNICAL CHARACTERISTICS- COOLING ONLYAQUACIAT POWERW ater chillersHeat pumps9 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - heat EXCHANGE - NA BAQUACIAT power ILD - ILDC - ILDH1200 V1500 V1650 V1800 VCooling capacity kW333382435487 Power input / ESEER / / / / capacity kW341387451503 Power input Lp (high-performance [HP] version)dB(A)93 / 6195 / 6396 / 6498 / 66Lw / Lp (Low Noise [LN] version)dB(A)91 / 5990 / 5891 / 5991 / 59Lw / Lp (XTRA Low Noise [XLN] version)dB(A)87 / 5587 / 5587 / 5588 / 56 CompressorHermetic scroll (2900 rpm)Start-up modeDirect inline cascadeQuantity46 Power controlNo.

10 Of stages4686% oil typePolyol ester Kow 3 MAF (32 cSt)Oil ,8No. of refrigerant lines2 Refrigerant (GWP)R410A (1720)Refrigerant chargeCircuit 1kg42434955 Circuit 2kg42435255 Electrical power supplyph/Hz/VThree-phase AC - 50 Hz - 400 V (+6%/-10%) + EarthMachine protection ratingIP44 Control circuit voltageph/Hz/VSingle-phase AC - 50 Hz - 230 V (+6%/-10%) - transformer fittedEvaporatorBrazed-plate heat exchangersWater Water outlet temp. (min ./ max.) C-12 / +18 Hot Water outlet temp. (min ./ max.) C+30 / +55 Minimum Water flow ratem3/h38435056 Maximum Water flow ratem3/h106110110110 Water DN 125 Max. pressure, Water endbar10 bar (ILD) / 4 bar (ILDC-ILDH)Air-cooled condenserFinned heat exchangerFanmm800No. x Motor output, high-performance (HP) version kW6 x x x Motor rated power High Performanceseries - LN - and Xtra Low Noise - XLNkW6 x x flow, high-performance (HP) versionm3/h121800117000159200156000 Air flow, low noise (LN) version andXTRA Low noise ( XLN) versionm3/h9000087600118400116800 Minimum system Water volumelTank volume, model Hl950 Expansion vessel, C & Hl50 (C version) - 80 (H version) on selection (page 10)Height (excluding mounts)mm2200 ( 2450 Xtra Low Noise version)Length (standard version)mm42605626 Length (version C)mm42605626 Length (version H)mm52896655 Widthmm2200 Weight (empty, standard version)kg3575403346484707 Weight (empty, version C)kg3935440850155074 Weight (empty, version H)kg4480494655605618 Storage temperature C+50 High-performance version capacities based on: EN 14511 Eurovent conditionsa/ COOLING.