Example: dental hygienist

Weksler Pressure and Temperature Instruments Full Line …

Weksler Pressure and . Temperature Instruments full Line catalog Bulletin WFL-1. 1. TABLE OF CONTENTS. 2. 3. Table of Contents PAGE PAGE. Selecting A Pressure 4 BIMETAL THERMOMETERS. Corrosion 5 Adjustable Angle TEST GAUGES. 3 Dial Size Rigid Forms 3A, 3S ..55. Accuracy (TG) .. 6 5 Dial Size Rigid Forms 5A, General Purpose Digital Gauges (DG).. 7 3 Dial Size Heavy Duty H3A, Pocket Bimetal IR, 2R, ROYAL & REGAL GAUGES. Sanitary Wells, Conversion Kit, Duct Process Gauges AA .. 11-13 60-63. Receiver Gauges AR ..14. Industrial Gauges 15-17 GLASS THERMOMETERS. Altitude Gauges BM, BN ..18 Adjustable Glass Thermometers Refrigeration & Ammonia Gauges BP, A735, 100mm Gauges Adjustable Air Duct Thermometers Duplex Gauges D735, Differential Gauges BC, BD.

Weksler® Pressure and Temperature Instruments Full Line Catalog Bulletin WFL-1

Tags:

  Catalog, Pressure, Temperatures, Instruments, Full, Weksler, 174 pressure and temperature instruments full, Weksler pressure and temperature instruments full

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Weksler Pressure and Temperature Instruments Full Line …

1 Weksler Pressure and . Temperature Instruments full Line catalog Bulletin WFL-1. 1. TABLE OF CONTENTS. 2. 3. Table of Contents PAGE PAGE. Selecting A Pressure 4 BIMETAL THERMOMETERS. Corrosion 5 Adjustable Angle TEST GAUGES. 3 Dial Size Rigid Forms 3A, 3S ..55. Accuracy (TG) .. 6 5 Dial Size Rigid Forms 5A, General Purpose Digital Gauges (DG).. 7 3 Dial Size Heavy Duty H3A, Pocket Bimetal IR, 2R, ROYAL & REGAL GAUGES. Sanitary Wells, Conversion Kit, Duct Process Gauges AA .. 11-13 60-63. Receiver Gauges AR ..14. Industrial Gauges 15-17 GLASS THERMOMETERS. Altitude Gauges BM, BN ..18 Adjustable Glass Thermometers Refrigeration & Ammonia Gauges BP, A735, 100mm Gauges Adjustable Air Duct Thermometers Duplex Gauges D735, Differential Gauges BC, BD.

2 22 Adjust Angle Digital Thermometers Reid Vapor Test RV ..23 AD35, Bellows Gauges Dimensions, Thermowells ..70. Metric Navy/Marine Thermometers Case Style & Dimensions .. 26-29 S520, GAUGE ACCESSORIES Economy Glass Thermometers Accessories/ 33-35 GAS ACTUATED THERMOMETERS. Gauge Cocks, Needle Valves, Remote Mounted Thermometers ECONOMY UTILITY GAUGES 313B,413B, 613B ..76. Dry How to Order Remote Gas Actuated Liquid Filled 44-46 77-78. Contractor Econo Gas Actuated Thermometers 313E, 413E, LINE ASSEMBLIES. How to Order Econo Gas Actuated 1115A/1115P Line 80-81. Case Styles, Materials, Descriptions, 82-85. Optional Bulb Temperature Conversion 4. Considerations in Selecting a Pressure Gauge RANGE Safety The maximum operating Pressure should not (solid front with blow-out back) warning: Misuse, Including Excessive exceed 75% of the full -scale range.

3 The normal Pressure , Vibration, Pulsation, Tempera- operating range should be in the middle half of Standard ture And Corrosion May Cause Failure the range (between 25% and 75% of the full - (open front with rubber blow-out disc at rear) That Can Result in Damage Or Injury. scale range); whenever possible. We suggest that users of Pressure Note A. ll safety case styles are designated Gauges refer to American National DIAL SIZE by a number. Standard case styles are Standard ASME entitled Gauges, designated by a letter. Select a dial size that allows you to comfortably Pressure And Vacuum Indicating Dial read the dial from the normal distance when WINDOW Type Elastic Element for guidance in installed. A glass face is standard in most gauges.

4 If Gauge selection. This document may breakage is a concern, a plastic or shatterproof be obtained from American Society of Pressure SYSTEM MATERIAL Mechanical Engineers (ASME) United glass face is optional at extra cost on most The media to which the gauge will be subjected Weksler Royal and Regal gauges. (Glycerin Engineering Center, 345 East 47th Street, is critical to the selection of the proper material filled and sanitary gauges have plastic face as New York, 10017. for the Bourdon tube, bellows, and socket. standard). Consult corrosion chart on page 5 for proper selection of Pressure system materials. POINTER. Weksler models are offered with: All Weksler gauges (except utility types) have Phosphor bronze Bourdon tube (or bellows).

5 Pressure Gauge Selection adjustable pointers. This permits pointer repo- with brass sockets. sitioning during calibration check or allows 316 stainless steel Bourdon tube (or maximum precision at a specific point. bellows) with 316 stainless steel sockets. 316 stainless steel Bourdon tube with alloy Temperature . steel sockets. The ambient Temperature to which the gauge Monel Bourdon tubes with Monel sockets. will be subjected should not exceed 150 F. If higher temperatures are encountered the gauge For applications where the above materials must be isolated from the source of heat. The may not be suitable, a diaphragm seal will Temperature of the media to which the gauge be necessary to protect the Pressure gauge is subjected to is also critical.

6 Gauges with system. phosphor bronze Bourdon tubes should not be ACCURACY subjected to process temperatures in excess Select a gauge with the desired accuracy as of 150 F. Gauges with metal cases and either follows: 316 stainless steel or monel bourdons can 1. /4% test gauges only (not for in-line withstand higher process temperatures , but service) as Temperature exceeds 150 F hardening of 1. /2% Weksler Royal gauges (41/2 dial the gasketing and discoloration of the dial may size and larger) and Weksler digital occur. In addition, accuracy will be affected gauges (21/2 case size) by approximately per 100 F. Both 316. 1% Weksler Regal gauges, 100 MM stainless steel and monel gauges in metal cases Gauge, EA14 gauge will withstand 750 F for short periods of time 2-1-2% Weksler duplex, differential and low without rupture, but other parts of the gauge Pressure gauges will be destroyed and calibration will be lost.

7 3-2-3% Weksler BY12, BY42, UA15, UA20, VIBRATION. UA25, UA35 series utility gauges If present, a glycerin filled gauge is MOVEMENT recommended. Select either a gauge with 300 series stainless PULSATION. steel movement for long wear or a gauge with If present, a Pressure snubber or throttle screw bronze or brass movement for applications is recommended. where vibration and pulsation are not present. CASE. A wide variety of case styles and materials are offered. Determine how the gauge is to be mounted: direct, surface (wall) or flush (in panel). Determine the desired case materials: polyproylene (or phenol); aluminum (black enameled) or stainless steel (300 series). Determine case type: 4. 5. Corrosion Chart The primary considerations in specifying The media being measured must be compatible instrument are recommended in applications with or purchasing a Pressure gauge are the with the wetted parts of the Pressure instrument.

8 Pulsation or vibration. These recommendations accuracy required and the media to be used To use the chart below, locate the media whose are only a guide, as service life is dependent on in its application. This corrosion chart has Pressure is to be measured and select a suitable Temperature , concentrations, catalysts that may material from those available. This is a simplified be added, or other conditions beyond our control. been prepared to assist you in the selection chart and assumes the media Temperature is below Consult customer service for specific applications of the gauge material that is best for your 200 F except for media with an* which must be and for any media not listed. installation requirement. below 100 F.

9 Throttling devices and/or a liquid filled Pressure Instrument Pressure Instrument Pressure Instrument Material Material Material Diaphragm seals**. Diaphragm seals**. Diaphragm seals**. Brass or bronze Brass or bronze Brass or bronze 316 SS. 316 SS. 316 SS. Monel Monel Monel MEDIA MEDIA MEDIA. Steel Steel Steel APPLICATION APPLICATION APPLICATION. Acetone* Crude Oil (Sour) Oxygen (Gas)(1) . Acetic Acid <40% Crude Oil (Sweet) Palmitic Acid >99%* . Acetic Anhydride Ethyl Acetate Phosphoric Acid <80%* . Acetylene (Dry) Ethylene Oxide >99%* Picric Acid <10% . Acrolein 100% Ferric Chloride <40% Propane (Dry) DOT Quality . Air Ferric Sulfate <10% Sea Water (Flowing) . Alcohol, Ethyl Ferrous Chloride <30% Silver Nitrate <70%.

10 Alum. Chloride >10% Ferrous Sulfate <50% Sodium Bicarbonate <20% . Alum. Sulfate 10-50% Fluorine Gas (Dry) No Air Sodium Bisulfate <30% . Ammonia Gas (Dry) Formaldehyde <95% Sodium Carbonate <40% . Ammonium Chloride <40% Formic Acid* Sodium Chromate <60% . Ammonium Nitrate <50% Freons Sodium Cyanide* . Ammonium Sulfate <60% Furfural <10% Sodium Hydroxide < 40% . Aniline>99% Gasoline (Flowing) Sodium Hypochlorite <25% . Argon Glycerin >99% Sodium Phosphate,Tri <60% . Beer Hydrobromic Acid Sodium Silicate <50% . Benzidine >99% Hydrochloric Acid Sodium Sulfide <50% . Benzene <50% Hydrofluoric Acid Stannous Chloride <10% . Benzoic Acid <70% Hydrofluosilic Acid Steam (Use siphon) . Boric Acid <25% Hydrogen(2) Stearic Acid.