wsat -XEEWSAN-XEE82 302 ELFOENERGY MEDIUMWSAT-XEE82S(1)400TN(2)1 PUS(3)-(4)AIR44R-410 AOHP (5)-(6)-(7)-(8)-(9)-(10)FC-(11)-(12)Euro vent EnergyEfficiency Class HYDRONIC functions and featuresavailable configurationsWater chillerWSAT-XEE: cooling onlyWSAN-XEE: reversible heat pumpAir cooledOutdoor installationCapacity from 24,3 to 72,2 kWLiquid chillers and heat pumps of the ELFOE nergy WSAT-XEE and WSAN-XEE series are units designed for outdoor installation and best energy efficiency in relation to their reduced ELFOE nergy series has been the turning point in the evolution of unit has been conceived and made by applying state-of-the-art technology, emphasising the qualities of EFFICIENCY, SELF-ADAPTATION and EASY INSTALLATION that distinguish this productThanks to its constructional and electronic peculiarities, ELFOE nergy permits.

WSAT-XEE WSAN-XEE 82÷302 ELFO ENERGY MEDIUM WSAT-XEE S 82 (1) 400TN (2) 1PUS (3)-(4) AIR R-410A OHP (5)-(6)-(7)-(8)-(9) …

Tags:

  Answ, Wsat xee wsan xee 82, Wsat, 247 302

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of WSAT-XEE WSAN-XEE 82÷302 - Clivet

1 wsat -XEEWSAN-XEE82 302 ELFOENERGY MEDIUMWSAT-XEE82S(1)400TN(2)1 PUS(3)-(4)AIR44R-410 AOHP (5)-(6)-(7)-(8)-(9)-(10)FC-(11)-(12)Euro vent EnergyEfficiency Class HYDRONIC functions and featuresavailable configurationsWater chillerWSAT-XEE: cooling onlyWSAN-XEE: reversible heat pumpAir cooledOutdoor installationCapacity from 24,3 to 72,2 kWLiquid chillers and heat pumps of the ELFOE nergy WSAT-XEE and WSAN-XEE series are units designed for outdoor installation and best energy efficiency in relation to their reduced ELFOE nergy series has been the turning point in the evolution of unit has been conceived and made by applying state-of-the-art technology, emphasising the qualities of EFFICIENCY, SELF-ADAPTATION and EASY INSTALLATION that distinguish this productThanks to its constructional and electronic peculiarities, ELFOE nergy permits.

2 4high energy efficiency, in particular during partial-load operation, thanks to the use of two compressors with different capacities that work on a single refrigerant circuit;4 Eurovent energy efficiency classification class "A" in heating operation, also in full load condition;4adaptability of operating parameters to the load conditions of the connected system, thereby optimising consumption, efficiency and working life of the parts;4easy, quick installation thanks to the standard hydronic group and the factory test carried out prior to dispatch;4installation of hydronic group with non-standard working head pumps or with double only( WSAT-XEE )Heating-Cooling( WSAN-XEE )A ir cooledOutdoor R-410 AHerm. ScrollELFOC ontrolIce protectionsystem ( WSAN-XEE only)(1) LOW TEMPERATURE:4 SStandard4 BLow water temperatureThis version allows unit operation within the water and glycol mixing temperature range between +4 C and -8 C set-point for water low temperature (Brine)(2) SUPPLY VOLTAGE:4400TN400/3/50+N(3) HYDRONIC GROUP USER SIDE:41 PUSS tandard pump 41 PURS ingle pump with reduced discharge head 41 PUMS ingle pump with larger discharge head42 PUSS tandard double pump 42 PURD ouble pump with reduced discharge head 42 PUMD ouble pump with larger discharge head4-Not required(4) ENERGY RECOVERY.

3 4-Not required (Standard)4 DPartial recoveryCarried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 25% of the total unit heat.(5) OPERATION ( WSAN-XEE only):4 OHPO peration in heat pump Cooling and heating unit (Standard)4 OHOO peration in heating-onlyHeating only unit(6) CONDENSER COIL:4 CCSS tandard condenser coil4 CCCAC ondenser coil in copper/aluminium with acrylic coating4 CCCA1 Condenser coil in copper/aluminium with Energy Guard DCC Aluminium treatment4 CCCCC ondenser coil in copper/copper(7) SOFT STARTER:4-Not required (Standard)4 SFSTR4 NDevice for inrush current reduction, for 400/3/50+N units(8) FREE CONTACTS HEATING EXTERNAL SIGNAL:4-Not required (Standard) 4 CLSEFree Contacts External Signal(9) SHUNT CAPACITORS (POWER FACTOR > 0,9):4-Not required (Standard) 4 PFCPS hunt capacitors (power factor > 0,9)(10) STORAGE TANK.

4 4-Not required (Standard) 4 ACC1 Teflon steel storage tank(11) FREE-COOLING ( WSAT-XEE only):4-Not required (Standard) 4 FCDD irect free-coolingFor technological air conditioning, and when the air temperature permits, the free-cooling option makes it possible to recover cold energy from the outdoor environment(12) REDUCED OUT. SECT. FAN CONSUMPTION ( WSAT-XEE only):4-Not required (Standard) 4 CREFBD evice for the reduction of ECOBREEZE type outdoor section fan consumptionFree-Cooling( WSAT-XEE only) 7422/03/11 14:3822/03/11 14 , ,9010,412,514,216,720,123,426,6-2,732,72 2,712,812,742,712,742,71-4,324,484,184,2 04,344,474,194,06kPa13212612010488148139 1314kW23,627,532,739,445,652,963,071,9kW 9,3610,913,015,317,821,025,028,4-2,522,5 32,512,572,562,512,522,53-4,074,113,853, 824,004,113,903,864kW28,832,937,545,653, 061,972,483,7kW9,0010,311,714,116,519,02 2,225,6-3,203,183,213,233,213,263,273, ,852,660,272,383,197, ,416,818,922,726,630,5-3,163,093,053,133 ,183,183,133,194kW29,233,638,046,954,163 ,374,085,4kW7,078,009,1011,213,315,618,2 21,1-4,134,214,154,194,074,054,074,05kPa 91,880,472,742,917,2111,2102,382,9-1-2 SCROLLdB(A)

5 6060606162626464V/Ph/Hz400/3/50+N8210212 2162182222262302170317031703193219321932 2332233267567567511001100110011001100120 9120912091417141714171417141747007007007 0070070070070070070070070070070070070070 0700700700700700700700700700700700700700 7007002983033234564694905475613153203705 30550580675690BB2B1AA2CA1technical data(1)Internal exchanger water = 12/7 C; air entering external exchanger = 35 C(2) Total input is obtained from the compressor input + fan input + auxiliary circuit input.(3)Ambient temperature = 7 C ( = 85%); internal exchanger water outlet temperature 45 C(4)Internal exchanger water = 23/18 C; air entering external exchanger = 35 C(5)Fresh air temperature = 7 C 6 C ; internal exchanger water temperature 30/35 C(6)Sound levels refer to units with full load under nominal test conditions.

6 The sound pressure is measured at 1 m from the external surface of the unit in open field referred to the following conditions:accessories Accessories supplied separately. 4 Rubber antivibration mounts 4 Serial communication module with supervisor (MODBUS) 4 Steel mesh filter on water side (when unit is in without hydronic group configuration) 4 High and low pressure gauges 4 Daily and weekly programming clock 4 Finned coil protection grilles 4 Phase monitor to check the presence and correct sequence of the power supply phases 4 Control keypad for remote installation that repeats all the functions already present on the onboard microprocessor control 4 Humidity probe for summer set point compensation according to the outside enthalpy and defrosting optimization in winter operationWSAT-XEE only: 4 Setpoint compensation on the basis of outdoor enthalpy WSAN-XEE only.

7 4 Setpoint compensation with outdoor air probeKey to symbols:dimensions and clearancesSizes Length (A)mmWidth (B)mmHeight (C)mm(A1)mm(A2)mm(B1)mm(B2)mmWSAT-XEEW eight in in above data refer to standard !For trouble-free operation of the unit it is essential to maintain the clearances in freeSizesApplication with terminal unitsWSAT-XEEC ooling capacity(1)Total input (1)(2)EER EUROVENT(1)ESEERPump working head(1)WSAN-XEEC ooling capacity(1)Total input (1)(2)EER EUROVENT(1)ESEERH eating capacity(3)Total input(2)(3)COP EUROVENT(3)Pump working head(1)Application with radiant panelsWSAN-XEEC ooling capacity(4)Total input (2)(4)EER EUROVENT(4)Heating capacity(5)Total input(2)(5)COP EUROVENT(5)Pump working head(4)Number of refrigerant circuitsNumber and type of compressorsSound pressure level(6)Power 7522/03/11 14:3822/03/11 14:38 REF-DG11C001GB-00