Example: dental hygienist

XCT Technology - the Lutron Advantage

XCTTM Technology the Lutron Advantage 15 ft 12 9 6 3 3 6 9 12 15. Lutron XCT Technology measures occupancy 3. in a whole new way, dramatically improving 6. 9. the performance of Lutron passive infrared 12. (PIR) sensors. Traditional PIR sensors can 15. 18. experience performance issues resulting from 21. insufficient sensitivity settings. 24 ft Lutron Maestro occupancy sensor 15 ft 12 9 6 3 3 6 9 12 15. XCT Technology enables the Lutron PIR sensor to 3. accurately distinguish between background noise and 6. motion. This enables the sensor to detect occupancy 9.

XCT TM technology – the Lutron advantage In accordance with NEMA testing standards, Lutron performed minor-motion coverage testing on the Maestro PIR occupancy sensor with XCT technology, and on four additional PIR occupancy

Tags:

  Technology, Lutron, Advantage, Technology the lutron advantage

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of XCT Technology - the Lutron Advantage

1 XCTTM Technology the Lutron Advantage 15 ft 12 9 6 3 3 6 9 12 15. Lutron XCT Technology measures occupancy 3. in a whole new way, dramatically improving 6. 9. the performance of Lutron passive infrared 12. (PIR) sensors. Traditional PIR sensors can 15. 18. experience performance issues resulting from 21. insufficient sensitivity settings. 24 ft Lutron Maestro occupancy sensor 15 ft 12 9 6 3 3 6 9 12 15. XCT Technology enables the Lutron PIR sensor to 3. accurately distinguish between background noise and 6. motion. This enables the sensor to detect occupancy 9.

2 Based solely on actual movement in the space. 12. Sensitivity adjustments are unnecessary. 15. 18. This breakthrough Technology recognizes noise as 21. being present in the measurement, enabling the sensor 24 ft to retain high sensitivity to fine motion (like turning Company 1 occupancy sensor the page of a book). As with standard PIR sensors, the 15 ft 12 9 6 3 3 6 9 12 15. Lutron sensor requires an unobstructed line-of-sight for 3. occupancy detection. 6. 9. 12. 15. 18. 21. 24 ft In accordance with NEMA testing standards, Company 2 occupancy sensor Lutron performed minor-motion coverage testing on the Maestro PIR occupancy sensor with XCT.

3 15 ft 12 9 6 3 3 6 9 12 15. Technology , and on four additional PIR occupancy 3. 6. sensors manufactured by others. The graphs 9. clearly demonstrate that sensors with XCT 12. Technology have the superior ability to detect 15. minor motion. 18. 21. 24 ft sensor Company 3 occupancy sensor greater than 75% detection rate 15 ft 12 9 6 3 3 6 9 12 15. 50% 75% detection rate 3. less than 50% detection rate 6. 9. 12. 15. 18. 21. 24 ft Company 4 occupancy sensor 1/2012 Lutron Electronics Co., Inc. | P/N 368-2523 REV A (PDF only).