Example: biology

XOS Elemental Analyzers Catalogue 2016 - …

XOS Elemental Elemental AnalyzersXOS Elemental Analyzers2 Sulfur AnalyzersSindie 7039 M-Series AnalyzerApplication Areas Total sulfur analysis from ultra low sulfur fuels to crudes. For use in refi nery labs, pipeline terminals, additive plants and inspection laboratories. Complies with ASTM D7039 and ISO & Benefi ts LOD: ppm at 300 s. Dynamic Range: Standard: ppm to 3000 ppm XR package: ppm to 10% Fits on any bench and compatible for use in mobile labs. 37 cm (w) x 50 cm (d) x 34 cm (h) Plug-it-in and measure: no additional utilities required. Touch Screen user interface. User programmable measurement time: 30-900 s. One calibration curve will run both diesel and gasoline up to 3000 ppm No conversion gasses, heating elements, quartz tubes or columns.

4 Sulfur Analyzers Sindie On-Line Analyzer The Sindie® On-Line model is an industrial-grade process sulfur analyzer designed for continuous …

Tags:

  Catalogue, Elemental, Analyzer, Xos elemental analyzers catalogue

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of XOS Elemental Analyzers Catalogue 2016 - …

1 XOS Elemental Elemental AnalyzersXOS Elemental Analyzers2 Sulfur AnalyzersSindie 7039 M-Series AnalyzerApplication Areas Total sulfur analysis from ultra low sulfur fuels to crudes. For use in refi nery labs, pipeline terminals, additive plants and inspection laboratories. Complies with ASTM D7039 and ISO & Benefi ts LOD: ppm at 300 s. Dynamic Range: Standard: ppm to 3000 ppm XR package: ppm to 10% Fits on any bench and compatible for use in mobile labs. 37 cm (w) x 50 cm (d) x 34 cm (h) Plug-it-in and measure: no additional utilities required. Touch Screen user interface. User programmable measurement time: 30-900 s. One calibration curve will run both diesel and gasoline up to 3000 ppm No conversion gasses, heating elements, quartz tubes or columns.

2 75 W air-cooled excitation tube. Robust polyamide window for easy : Extended Range package: from ppm up to 10%. LIMS data output software Sulfur AnalysisBenchtop, Portable and On-Line Sulfur AnalyzersThe Sindie product family delivers unprecedented accuracy and precision for petroleum and petrochemical Family Products: Sindie 7039 M-Series: Reliable Sulfur analyzer , designed to comply with ASTM D7039 and ISO 20884, with a Standard Dynamic Range of ppm to 3000 ppm. Sindie 7039 G3 M-Series: Enhanced precision sulfur analyzer with a Standard Dynamic Range of ppm to 10%. Sindie 2622 Bench-Top: Compact analytical solution for quantifi cation of total sulfur, offering two calibrations over a full dynamic range.

3 Sindie On-The-Go (OTG): Portable sulfur analysis, ideal for use in mobile labs and vans. Sindie On-Line: Industrial-grade process sulfur analyzer designed for continuous monitoring and testing, ideal for when measurement speed and reliability are essential with minimal maintenance 2622 Bench-Top AnalyzerApplication Areas: Total sulfur analysis from ultra low sulfur fuels to crudes. For use in refi nery labs, pipeline terminals, additive plants and inspection laboratories. Complies with ASTM D2622, D7039 and ISO and Benefi ts: LOD: ppm at 300 s. Dynamic Range: ppm to 10% Fits on any bench: 37 cm (w) x 50 cm (d) x 34 cm (h). Plug-it-in and measure: power is the only utility.

4 Touch Screen user interface. User programmable measurement time: 30-900 s. Two calibrations cover a variety of products over full dynamic range: 3000 ppm wt 10% wt No conversion gasses, heating elements, quartz tubes or columns. 75 W air-cooled excitation tube. Robust polyamide window for easy : LIMS data output software 7039 G3 M-Series AnalyzerApplication Areas Total sulfur analysis from ultra low sulfur fuels to crudes. For use in refi nery labs, pipeline terminals, additive plants, testing vans and inspection laboratories. Complies with ASTM D7039 and ISO & Benefi ts LOD: ppm at 300 s. Dynamic Range: Standard: ppm to 3000 ppm XR package: ppm to 10% Available with 8 cell auto-sampler.

5 Fits on any bench and compatible for use in mobile labs. Plug-it-in and measure: power is only utility. Touch screen user interface. Utilizes ACCU-CELL pre-assembled and pre-vented sample cups for enhanced precision, extreme ease-of-use and enhanced productivity. User programmable measurement time: 30-900 s. One calibration curve will run both diesel and gasoline up to 3000 ppm. No conversion gasses, heating elements, quartz tubes or columns. 75 W air-cooled excitation tube. Robust polyamide window for easy : Extended Range package: from ppm up to 10%. 8 cell Autosampler. LIMS data output software AnalyzersSindie On-Line AnalyzerThe Sindie On-Line model is an industrial-grade process sulfur analyzer designed for continuous sulfur monitoring and sulfur testing at, pipeline terminals, to monitor fuel interface cuts and tank contamination prevention where measurement speed and reliability are essential with minimal maintenance requirements.

6 It can also be used at refi neries for monitoring hydrotreating, hydrofi ner, and blending processes. Direct measurement without sample conversion; Analysis in ppm (wt). LOD: ppm. Dynamic Range: to 3000 ppm. Outstanding linearity: One calibration for diesel and gasoline matrixes over full dynamic range. Fast measurement time: 30 seconds to 5 minutes, user-programmable. No consumables, gases or high-temperature processes. Extremely low On-The-Go (OTG) Portable AnalyzerApplication Areas: Total sulfur analysis from ultra low sulfur fuels up to crude. For refi nery labs, pipeline terminals, on-board use, additive plants, testing vans and inspection laboratories.

7 Complies with ASTM D7039 and ISO and Benefi ts: Fits on any bench and compatible for use in mobile labs/vans. Dimensions: 33 cm (h) x 30 cm (w) x 23 cm (d). Weight: kg. Utility: Standard wall power: 100-240 VAC at A. No need for gasses, no high temp operating conditions. LOD: ppm at 900s Dynamic Range: ppm-10% ppm wt. User Interface: Touch Screen. ACCU-CELL pre-assembled sample cups for enhanced precision, operator ease-of-use and increased productivity. User programmable measurement time: 30-900 s. One calibration curve will run both diesel and gasoline. Extremely low maintenance: No conversion gasses, heating elements, quartz tubes or columns.

8 Robust polyimide window for easy cleaning. 20 W air-cooled excitation Bench-Top AnalyzerApplication Areas: Total Chlorine analysis from aqueous solutions and aromatic products to heavy fuels, crudes, and catalyst. For refi neries, petrochemical and additive plants, pipeline terminals, and test and Benefi ts: LOD: ppm wt. for hydrocarbons. Dynamic range: Standard: ppm wt. up to 3000 ppm wt. XR Package: ppm wt. up to 4% wt. Fits on any bench: 37 cm (w) x 50 cm (d) x 34 cm (h). Plug-it-in and measure. Standard wall power is only utility required. User-friendly with touch screen interface. User programmable measurement time: 30 -900 s Extremely low maintenance: - No conversion gasses - No columns - No heating elements - No quartz tubing Replaceable air-cooled x-ray tube.

9 No sample conversion or combustible gasses required. Robust polyimide window for easy Chlorine Analysis at Sub-ppm LevelsBenchtop and On-Line Chlorine AnalyzersThe Clora product family delivers unprecedented accuracy and precision for petroleum and petrochemical Family Products: Clora Bench-Top: Compact chlorine analyzer designed to measure hydrocarbons as well as aqueous solutions. LOD: ppm wt. for hydrocarbons; ppm wt. aqueous samples. Clora 2XP Bench-Top: Enhanced precision, ideal for those applications where low level detection is needed. LOD: ppm wt. in hydrocarbons; ppm wt. aqueous samples. Clora On-Line: Breakthrough analytical solution for quantifi cation of total chlorine from ppm up to 3000 AnalyzersClora 2XP Bench-Top AnalyzerAll the same features and benefi ts as above with the following key differences: LOD: ppm wt.

10 In hydrocarbons Dynamic range: ppm wt. up to 3000 ppm wt. Automatic sulfur correctionOptions: LIMS data output compatible software Extended Range capability; ppm up to 2%6HD MaxineHD Maxine assures precise determination of trace metals in crudes, lubricants and used oils without extensive sample preparation or expensive consumables. The analyzer enables the direct analysis of metals from Phosphorus to Lead, at unprecedented detection limits in a robust analyzer confi guration designed to perform in demanding petroleum and industrial environments. Plug it in and measure. Application Areas: Contaminants, Additives, Wear Metals. Refi neries, Lubricant Plants, Engine Service Centers.