Example: confidence

Z Pile Cover Plated - lbfoster-pilingproducts.com

Z pile ProfileCover Plated Z ProfileAvailable Grades: ASTM A572 Gr. 50 and 60, A588 and A690 +Values stated are nominal *Both sides of sheet excludes socket interior and ball interlockPer Single SectionPer Unit of WallSectionNormal WidthPlate SizeAreaWeightTotal Surface AreaNominal Coating Area*WeightMoment of InertiaSection ModulusFull Length PlatesHalf Length Platesininin lb / ftft / lftft / lftlb / ft lb / ft in / wftin / wftmmmmcm kg / mm / lmm / lmkg / m kg / m cm / wmcm / wmPZC 46-CP (PZC39) x x ,4004,630 PZC 48-CP (PZC39) x x ,1004,810 PZC 54-CP (PZC39) x x ,1005,370 PZC is a trademark of Gerdau*Excludes socket interior and ball interlock Best economy is obtained when plate length is limited to area of high moment.

www.lbfosterpiling.com Z-Profile Interlock All Gerdau Z-pile sections can be interlocked with each other. As such, the ball and socket interlocks can

Tags:

  Cover, Pile, Z pile cover plated, Plated

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Z Pile Cover Plated - lbfoster-pilingproducts.com

1 Z pile ProfileCover Plated Z ProfileAvailable Grades: ASTM A572 Gr. 50 and 60, A588 and A690 +Values stated are nominal *Both sides of sheet excludes socket interior and ball interlockPer Single SectionPer Unit of WallSectionNormal WidthPlate SizeAreaWeightTotal Surface AreaNominal Coating Area*WeightMoment of InertiaSection ModulusFull Length PlatesHalf Length Platesininin lb / ftft / lftft / lftlb / ft lb / ft in / wftin / wftmmmmcm kg / mm / lmm / lmkg / m kg / m cm / wmcm / wmPZC 46-CP (PZC39) x x ,4004,630 PZC 48-CP (PZC39) x x ,1004,810 PZC 54-CP (PZC39) x x ,1005,370 PZC is a trademark of Gerdau*Excludes socket interior and ball interlock Best economy is obtained when plate length is limited to area of high moment.

2 Filet weld should be sized to adequately resist design loads and should be continuous and all around. Cover plate length depends upon bending moment curve. Weld requirements should be speci ed by design +Height+Web Thickness+Flange Thickness+WeightMoment of InertiaSection ModulusNominal Coating Area*ininininlb / lftlb / ft in in / wftin in / wftft / lftmmmmmmmmkg / lmkg / m cm cm / wmcm cm / wmm / lmPZC ,69020,7609201, ,89022,4409901, ,15034,8901,1451, ,99037,7801,2351, ,07055,1901,7402, ,39058,4601,8402, , ,00062,1501,9502, , ,16098,2702,1003, , ,480104,1002,2203, , ,720109,7002,3404, Grades: ASTM A572 Gr. 50 HEIGHTWIDTHFLANGEWEBCOVER PLATE(SEE CHART)TYPICAL PZC 39 SHEET pile SECTIONHEIGHTWIDTHPZC Sheet pile RentalBenefits to renting PZC sheet pile : Made in the USA.

3 Low initial cost. Strategic stocking locations throughout the Interlocks warranted to be continuous and reasonably free-sliding to gradewhen threaded. Contractor preferred ball & socket interlocks. Wider, lighter, stronger PZC sheet pile maximizes job site efficiency. Why buy when you can RENT? take pride in the quality and service we offer with our rental program. Every sheet is warranted to be continuous and reasonably free-sliding to grade when ON FOSTER FOR ALL YOUR STEEL SHEET PILING RENTAL InterlockAll Gerdau Z- pile sections can be interlocked with each other. As such, the ball and socket interlocks can be installed with using either the standard or reverse position.

4 This adds to greater ease of use and flexibility at the job site. Normal setting width of pairs can be altered to accommodate job site conditions through increasing or decreasing the laying width at the interlocks.*Z- pile : Gerdau does not publish a swing value for Z-sections. Generally, it may be assumed that a 40 footlength would obtain a swing of up to 5 : All interlocks can be placed in reverse position with extruded 90 CobraPZ TeePZT-SColtJokerBullheadExtruded Z-Profile Connectors