Example: biology

ZYTEL 101L NC010 - txfbest.com

product information ddddZytel nylon resin ZYTEL 101l NC010 Nylon ResinValueDAM50%RHMechanical Tensile StrengthASTM D 638 MPa (kpsi) -40 C (-40 F)114 ( )110 ( ) 23 C (73 F)83 ( )77 ( ) 77 C (170 F)62 ( )41 ( ) 121 C (250 F)43 ( )38 ( ) Tensile Strength at YieldASTM D 638 MPa (kpsi) -40 C (-40 F)114 ( )110 ( ) 23 C (73 F)83 ( )58 ( ) 77 C (170 F)45 ( )34 ( ) 121 C (250 F)33 ( )28 ( ) Yield StressISO 527-1/-2 MPa (kpsi)83 ( )53 ( ) Elongation at YieldASTM D 638% -40 C (-40 F)4 23 C (73 F)525 77 C (170 F)3030 121 C (250 F)4540 Yield StrainISO 527-1/-2% DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, Mechanical properties measured at , ISO Electrical properties measured at , and all ASTM properties measured at Test temperatures are 23 C unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication.

d Product Information Zytelfi nylon resin Zytelfi 101L NC010 Nylon Resin Value DAM 50%RH Mechanical Tensile Strength ASTM D 638 MPa (kpsi)-40°C (-40°F) 114 (16.5) 110 (16.0)

Tags:

  Information, Product, Zytel, Nc010, Product information, 101l, Zytel 101l nc010

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ZYTEL 101L NC010 - txfbest.com

1 product information ddddZytel nylon resin ZYTEL 101l NC010 Nylon ResinValueDAM50%RHMechanical Tensile StrengthASTM D 638 MPa (kpsi) -40 C (-40 F)114 ( )110 ( ) 23 C (73 F)83 ( )77 ( ) 77 C (170 F)62 ( )41 ( ) 121 C (250 F)43 ( )38 ( ) Tensile Strength at YieldASTM D 638 MPa (kpsi) -40 C (-40 F)114 ( )110 ( ) 23 C (73 F)83 ( )58 ( ) 77 C (170 F)45 ( )34 ( ) 121 C (250 F)33 ( )28 ( ) Yield StressISO 527-1/-2 MPa (kpsi)83 ( )53 ( ) Elongation at YieldASTM D 638% -40 C (-40 F)4 23 C (73 F)525 77 C (170 F)3030 121 C (250 F)4540 Yield StrainISO 527-1/-2% DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, Mechanical properties measured at , ISO Electrical properties measured at , and all ASTM properties measured at Test temperatures are 23 C unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication.

2 This information may be subject to revision as newknowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-useconditions DuPont makes no warranties and assumes no liability in connection with any use of this information .

3 Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body. For other medical applications see "DuPont Medical Caution Statement", with DuPont Engineering Polymers - 101l NC010 is a lubricated PA 66 resin for injection MethodUnits 1 / 5 product information ZYTEL 101l NC010 ValueDAM50%RHMechanical Elongation at BreakASTM D 638% -40 C (-40 F)1520 23 C (73 F)60>300 77 C (170 F)>300>300 121 C (250 F)>300>300 Nominal Strain at BreakISO 527-1/-2%22>100 Tensile ModulusISO 527-1/-2 MPa (kpsi)3100 (450)1200 (174) Shear StrengthASTM D 732 MPa (kpsi)66 ( ) Poisson's Flexural ModulusASTM D 790 MPa (kpsi) -40 C (-40 F)3240 (470)3450 (500) 23 C (73 F)2830 (410)1210 (175) 77 C (170 F)690 (100)565 (82) 121 C (250 F)538 (78)414 (60)

4 Flexural ModulusISO 178 MPa (kpsi)2700 (392)1200 (174) Hardness, RockwellASTM D 785 Scale M7959 Scale R121108 Deformation Under LoadASTM D 621% 50 C (122 F), (2000psi) Tensile Impact StrengthASTM D 1822kJ/m2 (ft lb/in2) Long specimen504 (240)1470 (700) Short specimen157 (75)232 (110) Izod ImpactASTM D 256J/m (ft lb/in) -40 C (-40 F)32 ( )27 ( ) 23 C (73 F)53 ( )112 ( ) Notched Izod ImpactISO 180/1 AkJ/m2 -30 C (-22 F)54 23 C (73 F)513 Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, Mechanical properties measured at , ISO Electrical properties measured at , and all ASTM properties measured at Test temperatures are 23 C unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication.

5 This information may be subject to revision as newknowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-useconditions DuPont makes no warranties and assumes no liability in connection with any use of this information .

6 Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body. For other medical applications see "DuPont Medical Caution Statement", with DuPont Engineering Polymers - MethodUnits 2 / 5 product information ZYTEL 101l NC010 ValueDAM50%RHMechanical Notched Charpy ImpactISO 179/1eAkJ/m2 -30 C (-22 F)44 23 C (73 F)515 Unnotched Charpy ImpactISO 179/1eUkJ/m2 -30 C (-22 F)NBNB 23 C (73 F)NBNBT hermal Heat Deflection TemperatureASTM D 648 C ( F) (66psi)210 (410) (264psi)65 (149) Deflection TemperatureISO 75-1/-2 C ( F) (392) (158) Melting TemperatureISO 3146C C ( F)263 (505) CLTE, ParallelASTM E 831E-4/C (E-4/F) 23 - 55 C (73 - 130 F) ( ) CLTE, NormalASTM E 831E-4/C (E-4/F) 23 - 55 C (73 - 130 F) ( )

7 Thermal ConductivityASTM C 177W/m K (Btu in/h ft2 F) Conco-Fitch ( )Electrical Surface ResistivityIEC 60093ohm1 E12 Relative PermittivityIEC 60250 1E2 1E6 Volume ResistivityIEC 60093ohm m1E121E10 Dielectric ConstantASTM D 150 1E2 1E3 1E6 DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, Mechanical properties measured at , ISO Electrical properties measured at , and all ASTM properties measured at Test temperatures are 23 C unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as newknowledge and experience becomes available.

8 The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-useconditions DuPont makes no warranties and assumes no liability in connection with any use of this information .

9 Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body. For other medical applications see "DuPont Medical Caution Statement", with DuPont Engineering Polymers - MethodUnits 3 / 5 product information ZYTEL 101l NC010 ValueDAM50%RHElectrical Dissipation FactorASTM D 150 1E2 1E3 1E6 Dissipation FactorIEC 60250E-4 1E2 Hz802100 1E6 Hz180750 Electric StrengthIEC 60243-1kV/mm (V/mil) (800) CTIIEC 60112V Flammability ClassificationUL94 Oxygen IndexASTM D 2863%2831 Oxygen IndexISO 4589%28 High Amperage Arc Ignition ResistanceUL 746 Aarcs186 High Voltage Arc Tracking RateUL 746 Amm/min (in/min) ( )

10 Hot Wire IgnitionUL 746As15 Temperature Index RTI, ElectricalUL 746B C RTI, Mechanical with ImpactUL 746B C RTI, Mechanical without ImpactUL 746B C DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, Mechanical properties measured at , ISO Electrical properties measured at , and all ASTM properties measured at Test temperatures are 23 C unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as newknowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.