Backflow Prevention
Found 14 free book(s)PUBLIC SWIMMING POOL AND SPA OPERATING …
cchealth.org3. Backflow Prevention • Threaded faucets and submerged water supply inlets must be protected with approved backflow prevention devices. 4. Safety Equipment The following safety equipment must be provided: • Life ring (minimum 17 inch exterior diameter) with attached 3/16 inch rope long enough to span the maximum width of the pool.
Report on Test and Maintenance of Backflow Prevention …
www.health.ny.govREPORT ON TEST AND MAINTENANCE OF BACKFLOW PREVENTION DEVICE PART A - To Be Completed by Certified Tester # Indicate the test year and whether initial or annual test. # Complete public water supply name, customer account number (if available) and county. # Complete block and lot (if available) for New York City Metropolitan area tests.
SUBCHAPTER E: BACKFLOW PREVENTION AND CROSS …
www.tceq.texas.govThe backflow prevention device must be installed in accordance with the laboratory approval standards or if the approval does not include specific installation information, the manufacturer's current published recommendations. (b) If conditions that present a health hazard exist, one of the following methods must be used to ...
City of Phoenix Water Services Department
www.phoenix.govBackflow: The flow of water or other liquids, mixtures, gases, or other substances into the distributing pipes of a potable supply of water, from any source or sources other than the City potable water system. Backflow Prevention Device - Approved: An air-gap, double check valve assembly, reduced pressure principle backflow
Sample Exam Questions and Recommended References for …
www.abccert.org2. To avoid creating water hammer, when returning a backflow prevention assembly to service the tester should A. Slowly pressurize the assembly and then slowly pressurize the downstream piping B. Slowly pressurize the downstream piping and then slowly pressurize the assembly C. Close shut-off valve #2 after opening shut-off valve #1
Sprinkler Planning & Installation Guide
media.toro.comalso tell you about requirements for the backflow prevention devices required in your area . These devices protect your water supply from contamination and are required for inground irrigation systems . WArning! Serious injury may result from damaging buried …
Please use a separate form for each assembly
www1.nyc.govCertified Backflow Prevention Assembly Tester shall fill out this portion in A. LL . cases: Include the line pressure (taken at number 1test cock with shutoff valve number closed). Include thepressuredrop across first check valve (the differential between second and third test cocks). Include the condition of check valves # 1 and 2.
DEPARTMENT OF ENVIRONMENTAL PROTECTION - BUREAU …
www1.nyc.gov6) Note Manufacturer, model # in full, size & type of each backflow prevention assembly. 7) Indicate name, mailing address & phone number and signature of property owner/customer. Be sure this information is precise and active. Failure to provide correct property owner/customer mailing address will result in delayed notification.
Backflow Preventers and Protection of Water Supply: 2015 IPC
iccsafe.orgbackflow prevention methods and devices in an organized and user-friendly approach in accordance with the requirements of the 2015 International Plumbing Code® (IPC ®) and International Residential Code (IRC®). It covers: • Cross connection potential and where backflow protection is required. • Backflow prevention devices, methods and ...
Backflow Prevention for Fire Sprinkler Systems
firesprinklertesting.orgThe backflow prevention assembly shall be forward flow tested to ensure proper operation. The minimum flow rate shall be the system demand, including hose stream where applicable. This is a requirement also called out in NFPA 25 1998 Edition
Backflow Prevention and Cross-Connection Control
www.awwa.org2 BACKFLOW PREVENTION AND CROSS-CONNECTION CONTROL AWWA Manua M14 RESPONSIBILITIES The United States Safe Drinking Water Act (SDWA) became law in 1974. The purpose of the act is to protect public health by regulating all public drinking water supplies in the United States. SDWA was amended in 1986 and again in 1996.
Backflow Prevention - Watts
media.wattswater.comBackflow Prevention Fluid Control Product Catalog FEBCOonline.com. FEBCO is an ISO 9001 Certified manufacturer of high quality fluid control products. For over 80 years FEBCO has been committed to manufacturing excel-lence and innovative design and dedicated to …
LEAD FREE Series LF009 - Watts
media.wattswater.comvariety of installations, including the prevention of health hazard cross-connections in piping systems or for containment at the service line entrance. The LF009 features Lead Free* construction to comply with Lead Free* installation requirements. This series features two in-line, independent check valves, captured
Hemodialysis Central Venous Catheter Scrub-the-Hub …
www.cdc.govPrevention of Intravascular Catheter-Related Infections, prior to accessing the catheter hub it should be disinfected with an appropriate antiseptic (greater than 0.5% chlorhexidine with alcohol, 70% alcohol, or 10% povidone-iodine). There is not enough evidence to recommend one antiseptic over the others.