Roof Sheathing
Found 9 free book(s)ADVANTECH® SHEATHING - Huber Engineered Woods
www.huberwood.com• Wall sheathing • Production (LEED for Homes)Roof sheathing • 2- Layer floating subfloor • Shear walls . LIMITATIONS ON USE . When installing designers should AdvanTech sheathing, incorporate a 1/8” expansion joint to accommodate panel expansion. This is an industry recommendation and is not unique to AdvanTechsheathing.
Roof Assemblies - Florida Building
floridabuilding.orgsheathing thickness is greater than 15/32 inches, roof sheathing is required to be fastened with ASTM F1667 RSRS-03 (2 ½" × 0.131") nails or ASTM F1667 RSRS-04 (3" × 0.120") nails. The RSRS designation indicates the fastener is a ring shank roof sheathing nail. Table R803.2.3.1 specifies the maximum fastener
INSPECTION CHECKLIST Residential Re-roof
mybuildingpermit.comPrior to installing roof coverings on all roofs having a slope of 2:12 or less. Nailing or Progress Inspection Where the existing roofing material is being completely removed and replaced, and the underlying sheathing is being replaced or added over skip sheathing, a nailing inspection is required prior to any roofing materials being placed.
Parts of a Roof - Consumers' Checkbook
www.checkbook.orga roof per 12 inches of horizontal distance. Rafter—A structural member (usually slanted) to which sheathing is attached. Rake—The slanting edge of a gable roof at the end wall of the house. Ridge—The horizontal line at the top edge of two sloping roof planes. Sheathing—The decking material (usually sheets of
Framing a Roof - Berlin-Boylston Regional School District
www.bbrsd.orgvalley, sheathing, fascia, soffit, dormer, and pitch. •Label and identify the parts of a roof framing plan. Parts of a Roof •A Ridge Board is a horizontal member of the roof frame. The point at which all the rafters are attached to. •Transfers the load of the roof
Class A, B, and C Roof Ratings - UL Code Authorities
code-authorities.ul.comsheathing (oriented strandboard panels, structural particleboard panels, composite panels or waferboard panels) are suitable alternatives when a certified underlayment is utilized between the sheathing and the prepared roof covering. Roofing systems consist of a combination of materials intended to be installed on combustible or
Installation Manual-ZIP System Sheathing-Wall and Roof
www.huberwood.comZIP System® R-Sheathing panels consist of a 7/16-inch oriented strand board panel laminated with a water-resistive facer on the exterior and a rigid foam insulation panel bonded on the opposite (interior) face. When properly installed and taped, ZIP System® R-Sheathing provides a water-resistive barrier, air barrier and exterior
APA RATED SHEATHING - APAwood.org
www.apawood.orgAPA Rated Sheathing is rated for use as subfloor, wall, roof, diaphragm and shear wall sheathing. It is suitable for use in a range of construction and miscellaneous applications where strength and stiffness are required. 2.1 Adhesive Bond Classification The bond classification relates to moisture resistance of the
DuPont Thermax Sheathing
www.dupont.comThermax™ Sheathing is manufactured from 100% renewable power and has a zero ozone depleting potential and negligible global warming potential. The use of Thermax™ Sheathing helps reduce the carbon footprint of commercial buildings and can contribute to LEED Credits. * Thermax ™ Sheathing is a former product of The Dow Chemical Company.