Search results with tag "Occupancy sensor"
Dual Technology Ceiling Mount Sensor
www.lutron.comSensors LOS-CDT Series Occupancy Sensors 369653c 3 02.07.13 ower packs may be required when interfaced to LutronP R lighting control systems. If more than 1 occupancy sensor is connected to the same input, a power pack is required. A maximum of 3 occupancy sensors can be connected to the same input.
SRT2 EDGE-LIT - hubbellcdn
hubbellcdn.comWIRSC924 wiSCAPE® + occupancy sensor with UL924 dimming bypass module for controls override3 SiteSync SWP SiteSync3,6,9 SWPM SiteSync with occupancy sensor3,6,9 Sensor Controls SCP-8F Remote control programmable line voltage sensor (8-12' recommended MH)2 SCP-20F Remote control programmable line voltage sensor (12-20' recommended MH)2
Custom Settings for Maestro Occupancy Sensing Switches …
www.lutron.com• Auto-ON / Auto-OFF (Occupancy Mode)*: This is the default setting of the occupancy sensors. The sensor automatically turns on when you enter the room, and turns off when you vacate the room. This setting is also known as “Occupancy” mode. • Manual-ON / Auto - OFF (Vacancy Mode): This is the default setting for vacancy sensors. The ...
Energi Savr Node T - Dimmers And Lighting Controls
www.lutron.comOccupancy Sensors (continued) • Occupancy sensor must provide a dry contact clo-sure or solid-state output. • Additional occupancy sensors can be used with the Energi Savr NodeT unit. Refer to the “Programming Options and Features” table for system rules. Infrared (IR) Receivers • Use Lutron IR receivers and compatible transmitters
Controller Operator Guide VariTrac
www.trane.comCommunicating sensor assembly including a UCM 4 with integral temperature and pressure sensor, and output to the bypass damper(s) Bypass damper with factory-installed wiring harness for plug-in connection to the communicating sensor assembly Zone dampers with UCM 4 boards and: – Zone occupancy sensor input – Zone (carbon dioxide) CO
Lighting Efficiency - Stanford University
large.stanford.edupurposes, and certain types of sensors and light fixtures are more appropriate together than others. For example, lamps that take a long time to start are not suitable for sensors that turn off and on frequently. o Occupancy sensors help ensure …
Manual-ON Occupancy Sensor - Leviton
www.leviton.comThe unit installs in place of a single pole or 3-way wall switch and fits in a standard wallbox. The unit can be used for switching incandescent, fluorescent and electronic or magnetic low voltage lighting with ballasts. Decora ® The IPP15-1L uses passive infrared (PIR) detection technology to Manual-ON Occupancy Sensor IPP15-1L monitor a room ...
Maestro 0-10V dimmer sensor - Lutron Electronics, …
www.lutron.comIn-wall Maestro sensor switches and dimmers for additional applications Maestro ® 0–10V Dimmer Occupancy Sensor * XX denotes color suffix Model Model number Description Voltage
FBX LED high bay Industrial - Signify
www.signify.com8 High bay motion detector, Motion sensing zone is extremely limited if used below 15' mounting ... · Occupancy sensors are integral to each luminaire, with embedded automatic dimming behaviors appropriate to multiple applications. Applications modes are selected using the handheld remote control. · Dimming sensors are integral to each ...
Mirada Large (MRL)
www.lsicorp.comPole-Mounted Occupancy Sensor (24V)8,9 663284CLR Shorting Cap for use with CR7P7 149328 Fusing Options10 Description Order Number Single Fusing (120V) See Fusing Accessory Guide Single Fusing (277V) Double Fusing (208V, 240V) Double Fusing (480V) Double Fusing (347V) Shielding & Miscellaneous Accessories Description Order Number Integral Louver ...
2019 Energy Code
www.energy.ca.govLED light sources installed outdoors. ... must be controlled by occupancy sensors that reduces power by at least 50%. 150.0(k)3A Single-Family Outdoor Lighting • Must be high efficacy ... • Parking lots/carports with 8 or more cars oMeet nonresidential lighting requirements
Parking Structure Lighting Guide - Energy
www.energy.govramp and entrance lighting levels to save additional energy at night. If considering adding occupancy sensors to turn lights down or off during low activity periods, consider whether to turn off individual luminaires or reduce output for a group of luminaires. Turning off luminaires may result in poorer lighting uniformity on the pave-
CONTROL - Hubbell Wiring Device
ecatalog.hubbell-wiring.comwwwhubbellwiringcom 6 These diagrams visually represent occupancy sensor design recommendations based on specific spaces in different building types
Dual Technology Ceiling Mounted Line Model # …
www.cooperindustries.comInstallation Instructions Model # OAC-DT-2000-MV Model # OAC-DT-2000-DMV Dual Technology Ceiling Mounted Line Voltage Occupancy Sensor • Read all instructions on both sides of this sheet first
Similar queries
Dual Technology Ceiling Mount Sensor, Sensors, Occupancy sensors, Lighting, Occupancy, SRT2 EDGE-LIT, Occupancy Sensor, Sensor, Guide, Lighting Efficiency, Leviton, Wall switch, Decora, Maestro 0-10V dimmer sensor, Lutron Electronics, High bay, Applications, Parking, CONTROL, Dual Technology Ceiling Mounted Line