Transcription of CAER - CCMPA
{{id}} {{{paragraph}}}
SEISMIC design GUIDE FOR MASONRY BUILDINGS Canadian Concrete Masonry Producers AssociationDonald Anderson Svetlana BrzevApril 2009 CHAPTER 4 DISCLAIMER While the authors have tried to be as accurate as possible, they cannot be held responsible for the designs of others that might be based on the material presented in this document. The material included in this document is intended for the use of design professionals who are competent to evaluate the significance and limitations of its contents and recommendations and able to accept responsibility for its application.
4/1/2009 4-2 4 Design Examples EXAMPLE 1: Seismic load calculation for a low-rise masonry building to NBCC 2005 Consider a single-storey warehouse building located in Mississauga, Ontario.
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}